Literature DB >> 15531305

Position of angle-supported, iris-fixated, and ciliary sulcus-implanted myopic phakic intraocular lenses evaluated by Scheimpflug photography.

Martin Baumeister1, Jens Bühren, Thomas Kohnen.   

Abstract

PURPOSE: To examine postoperative positional stability of myopic phakic intraocular lenses (IOLs).
DESIGN: Prospective, nonrandomized clinical study.
METHODS: The study included 46 eyes which received an anterior chamber angle-supported (Bausch & Lomb NuVita; 10 eyes), anterior chamber iris-fixated (Ophtec Artisan; 20 eyes) or ciliary sulcus-implanted phakic IOL (Staar ICL; 16 eyes). The distance between the phakic IOL and the crystalline lens and the cornea as well as rotation around the optical axis was evaluated using Scheimpflug photography at 1, 3 to 6, and 12 months postsurgery.
RESULTS: The anterior chamber phakic IOLs showed no significant movement in anteroposterior direction. The posterior chamber phakic IOL showed a significant movement toward the crystalline lens between postoperative months 3 and 12. The median amount of rotation around the optical axis between the 3- and the 12-month evaluation was 1.9 degrees (range = 0.0-33.5 degrees) for the NuVita, 0.6 degrees (range = 0.0-3.5 degrees) for the Artisan, and 0.9 degrees (range = 0.2-2.3 degrees) for the ICL. Four NuVita IOLs rotated more than 10 degrees.
CONCLUSIONS: The angle-supported anterior chamber phakic IOLs showed a generally stable position regarding distance to cornea and natural lens, but rotation was observed in four IOLs. The iris-fixated phakic IOL showed the highest overall stability. The posterior chamber phakic IOL was stable in terms of rotation but had a tendency to decrease in distance toward the crystalline lens. Intraocular lenses implanted in phakic eyes followed for 12 months demonstrate stable IOL position overall.

Entities:  

Mesh:

Year:  2004        PMID: 15531305     DOI: 10.1016/j.ajo.2004.06.009

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  15 in total

1.  Long-term evaluation of the central vault after phakic Collamer® lens (ICL) implantation using OCT.

Authors:  Jose F Alfonso; L Fernández-Vega; C Lisa; P Fernandes; J González-Meijome; R Montés-Micó
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-02-28       Impact factor: 3.117

2.  Three-year follow-up of subjective vault following myopic implantable collamer lens implantation.

Authors:  José F Alfonso; Carlos Lisa; A Abdelhamid; Paulo Fernandes; Jorge Jorge; Robert Montés-Micó
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-03-24       Impact factor: 3.117

Review 3.  [Intraocular lenses for the correction of refraction errors. Part II. Phakic posterior chamber lenses and refractive lens exchange with posterior chamber lens implantation].

Authors:  T Kohnen; T Kasper; E Terzi
Journal:  Ophthalmologe       Date:  2005-11       Impact factor: 1.059

Review 4.  [Intraocular lenses for the correction of refraction errors. Part 1: phakic anterior chamber lenses].

Authors:  T Kohnen; M Baumeister; M Cichocki
Journal:  Ophthalmologe       Date:  2005-10       Impact factor: 1.059

Review 5.  [Scheimpflug photography for the examination of phakic intraocular lenses].

Authors:  M Baumeister
Journal:  Ophthalmologe       Date:  2014-10       Impact factor: 1.059

6.  [Biometry of the anterior eye segment for implantation of phakic anterior chamber lenses. A comparison of current measurement devices].

Authors:  L Kiraly; G Duncker
Journal:  Ophthalmologe       Date:  2012-03       Impact factor: 1.059

Review 7.  [Possibilities for use of Scheimpflug technology in cataract surgery].

Authors:  D M Handzel; C H Meyer; A Wegener
Journal:  Ophthalmologe       Date:  2014-10       Impact factor: 1.059

8.  Toric implantable collamer lens for moderate to high myopic astigmatism: 3-year follow-up.

Authors:  Esin Sogutlu Sari; David P Pinero; Anil Kubaloglu; Pinar Sorgun Evcili; Arif Koytak; Isil Kutlutürk; Yusuf Ozerturk
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-10-10       Impact factor: 3.117

9.  Pseudophacomorphic Glaucoma along with Pupillary Block after Visian™ Implantable Collamer Lens Implantation for High Myopia.

Authors:  Michael V McCaughey; Thomas Mifflin; Carlton R Fenzl; Jason Goldsmith; Majid Moshirfar
Journal:  Open J Ophthalmol       Date:  2014-11

10.  Stability of cachet phakic intraocular lens position during 6-months follow-up.

Authors:  D Schiano Lomoriello; M Lombardo; L Gualdi; L Iacobelli; L Tranchina; P Ducoli; S Serrao
Journal:  Open Ophthalmol J       Date:  2013-03-22
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.