Literature DB >> 15515343

Loaded custom-made zirconia and titanium implants show similar osseointegration: an animal experiment.

Ralf J Kohal1, Dietmar Weng, Maria Bächle, Jörg R Strub.   

Abstract

BACKGROUND: Zirconia might be an alternative material to titanium for dental implant fabrication. The aim of the present study was to investigate the histological behavior (osseointegration) of loaded zirconia implants in an animal model and to compare it with the behavior of titanium implants.
METHODS: Five months after extraction of the upper anterior teeth, 12 custom-made titanium implants (control group) and 12 custom-made zirconia implants (test group) were inserted in the extraction sites in six monkeys. Before insertion, the titanium implant surfaces were sandblasted with Al2O3 and subsequently acid-etched. The zirconia implants were only sandblasted. Six months following implant insertion, impressions were taken for the fabrication of single crowns. A further 3 months later, nonprecious metal crowns were inserted. Five months after insertion of the crowns, the implants with the surrounding hard and soft tissues were harvested, histologically prepared, and evaluated under the light microscope regarding the peri-implant soft tissue dimensions and mineralized bone-to-implant contact.
RESULTS: No implant was lost during the investigational period. The mean height of the soft peri-implant tissue cuff was 5 mm around the titanium implants and 4.5 mm around the zirconia implants. No statistically significant differences were found in the extent of the different soft tissue compartments. The mean mineralized bone-to-implant contact after 9 months of healing and 5 months of loading amounted to 72.9% (SD: 14%) for the titanium implants and to 67.4% (SD: 17%) for the zirconia implants. There was no statistically significant difference between the different implant materials.
CONCLUSION: Within the limits of this animal experiment, it can be concluded that the custom-made zirconia implants osseointegrated to the same extent as custom-made titanium control implants and show the same peri-implant soft tissue dimensions.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15515343     DOI: 10.1902/jop.2004.75.9.1262

Source DB:  PubMed          Journal:  J Periodontol        ISSN: 0022-3492            Impact factor:   6.993


  26 in total

Review 1.  Implant biomaterials: A comprehensive review.

Authors:  Monika Saini; Yashpal Singh; Pooja Arora; Vipin Arora; Krati Jain
Journal:  World J Clin Cases       Date:  2015-01-16       Impact factor: 1.337

Review 2.  Zirconia surface modifications for implant dentistry.

Authors:  Fernanda H Schünemann; María E Galárraga-Vinueza; Ricardo Magini; Márcio Fredel; Filipe Silva; Júlio C M Souza; Yu Zhang; Bruno Henriques
Journal:  Mater Sci Eng C Mater Biol Appl       Date:  2019-01-16       Impact factor: 7.328

3.  Comparison of peri-implant bone formation around injection-molded and machined surface zirconia implants in rabbit tibiae.

Authors:  Hong-Kyun Kim; Kyung Mi Woo; Won-Jun Shon; Jin-Soo Ahn; Seunghee Cha; Young-Seok Park
Journal:  Dent Mater J       Date:  2015       Impact factor: 2.102

4.  Response of osteoblast-like cells cultured on zirconia to bone morphogenetic protein-2.

Authors:  Seung-Hee Han; Kyoung-Hwa Kim; Jung-Seok Han; Ki-Tae Koo; Tae-Il Kim; Yang-Jo Seol; Yong-Moo Lee; Young Ku; In-Chul Rhyu
Journal:  J Periodontal Implant Sci       Date:  2011-10-31       Impact factor: 2.614

5.  Zirconia Implants in Esthetic Areas: 4-Year Follow-Up Evaluation Study.

Authors:  Andrea Enrico Borgonovo; Rachele Censi; Virna Vavassori; Oscar Arnaboldi; Carlo Maiorana; Dino Re
Journal:  Int J Dent       Date:  2015-06-01

Review 6.  Influence of implant location on the clinical outcomes of implant abutments: a systematic review and meta-analysis.

Authors:  Amr G ElHoussiney; He Zhang; Jinlin Song; Ping Ji; Lu Wang; Sheng Yang
Journal:  Clin Cosmet Investig Dent       Date:  2018-02-26

7.  Osseointegration of zirconia implants compared with titanium: an in vivo study.

Authors:  Rita Depprich; Holger Zipprich; Michelle Ommerborn; Christian Naujoks; Hans-Peter Wiesmann; Sirichai Kiattavorncharoen; Hans-Christoph Lauer; Ulrich Meyer; Norbert R Kübler; Jörg Handschel
Journal:  Head Face Med       Date:  2008-12-11       Impact factor: 2.151

Review 8.  Zirconia in dental implantology: A review.

Authors:  Abhishek Apratim; Prashanti Eachempati; Kiran Kumar Krishnappa Salian; Vijendra Singh; Saurabh Chhabra; Sanket Shah
Journal:  J Int Soc Prev Community Dent       Date:  2015 May-Jun

9.  Two-piece zirconia implants supporting all-ceramic crowns: a prospective clinical study.

Authors:  Norbert Cionca; Nada Müller; Andrea Mombelli
Journal:  Clin Oral Implants Res       Date:  2014-03-26       Impact factor: 5.977

Review 10.  A systematic review of the clinical survival of zirconia implants.

Authors:  Dena Hashim; Norbert Cionca; Delphine S Courvoisier; Andrea Mombelli
Journal:  Clin Oral Investig       Date:  2016-05-24       Impact factor: 3.573

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.