Literature DB >> 1549669

Threshold perception performance with computed and screen-film radiography: implications for chest radiography.

J T Dobbins1, J J Rice, C A Beam, C E Ravin.   

Abstract

Images of a phantom obtained with computed radiography and standard screen-film imaging were compared to evaluate observer threshold perception performance with a modified contrast-detail technique. Optimum exposure necessary for performance with the imaging plate technique to match that with screen-film techniques was determined, as was comparative performance with variation in kilovoltages, plate type, spatial enhancement, and hard-copy interpolation method. It was found that computed radiography necessitates about 75%-100% more exposure than screen-film radiography to optimally match performance with Ortho-C film with Lanex regular or medium screens (Eastman Kodak, Rochester, NY) for detection of objects 0.05-2.0 cm in diameter. However, only minimal loss of detection performance (approximately 10% overall) was experienced if standard screen-film exposures were used with computed radiography. Little change in observer performance was found with variation in plate type, spatial enhancement, or method of hard-copy interpolation. However, perception performance with computed radiographic images was better at lower kilovoltages.

Mesh:

Year:  1992        PMID: 1549669     DOI: 10.1148/radiology.183.1.1549669

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  11 in total

1.  Optimization of a contrast-detail-based method for electronic image display quality evaluation.

Authors:  N J Hangiandreou; K A Fetterly; J P Felmlee
Journal:  J Digit Imaging       Date:  1999-05       Impact factor: 4.056

2.  A method to produce and validate a digitally reconstructed radiograph-based computer simulation for optimisation of chest radiographs acquired with a computed radiography imaging system.

Authors:  C S Moore; G P Liney; A W Beavis; J R Saunderson
Journal:  Br J Radiol       Date:  2011-10       Impact factor: 3.039

3.  Emergency CT brain: preliminary interpretation with a tablet device: image quality and diagnostic performance of the Apple iPad.

Authors:  Patrick Mc Laughlin; Siobhan O Neill; Noel Fanning; Anne Marie Mc Garrigle; Owen J O Connor; Gerry Wyse; Michael M Maher
Journal:  Emerg Radiol       Date:  2011-12-16

4.  Computed radiography dual energy subtraction: performance evaluation when detecting low-contrast lung nodules in an anthropomorphic phantom.

Authors:  C Kimme-Smith; D L Davis; M McNitt-Gray; J Goldin; E Hart; P Batra; T D Johnson
Journal:  J Digit Imaging       Date:  1999-02       Impact factor: 4.056

5.  Impact of a training course on the quality of chest radiography to diagnose pulmonary tuberculosis.

Authors:  A Ohkado; P Luna; A Querri; M Mercader; S Yoshimatsu; L Coprada; R Bañares; A M C Garfin; T Date
Journal:  Public Health Action       Date:  2015-03-21

6.  Quantitative evaluation of overall electronic display quality.

Authors:  N J Hangiandreou; K A Fetterly; S N Bernatz; L J Cesar; D S Groth; J P Felmlee
Journal:  J Digit Imaging       Date:  1998-08       Impact factor: 4.056

7.  Support line and tube visibility in chest examinations using computed radiography.

Authors:  W Huda; C J Belden; L A Webb; C K Palmer
Journal:  J Digit Imaging       Date:  1997-08       Impact factor: 4.056

8.  Optimisation of radiological protocols for chest imaging using computed radiography and flat-panel X-ray detectors.

Authors:  G Compagnone; M Casadio Baleni; E Di Nicola; M Valentino; M Benati; L F Calzolaio; N Oberhofer; E Fabbri; S Domenichelli; L Barozzi
Journal:  Radiol Med       Date:  2012-10-22       Impact factor: 3.469

9.  Correlation of the clinical and physical image quality in chest radiography for average adults with a computed radiography imaging system.

Authors:  C S Moore; T J Wood; A W Beavis; J R Saunderson
Journal:  Br J Radiol       Date:  2013-04-08       Impact factor: 3.039

10.  Characterization and validation of the thorax phantom Lungman for dose assessment in chest radiography optimization studies.

Authors:  Sunay Rodríguez Pérez; Nicholas William Marshall; Lara Struelens; Hilde Bosmans
Journal:  J Med Imaging (Bellingham)       Date:  2018-02-06
View more