Effects of RF amplifier distortion on selective excitation and their correction by prewarping.

F Chan1, J Pauly, A Macovski.   

Abstract

In a magnetic resonance imaging system, an RF power amplifier is employed to boost an RF pulse to sufficient strength to excite the nuclear spins in a subject. The nonideal behavior of this amplifier distorts a selective-excitation pulse, and this distortion in turn degrades the slice profile. We have found two types of nonideal behavior particularly troublesome: nonlinearity and incidental phase modulation. One of their effects is the introduction of an unwanted "skirt" in the out-of-slice region of a slice profile. We present an effective method of correction in which a selective-excitation pulse is prewarped to compensate for the distortion.

Mesh:

Year:  1992        PMID: 1549038     DOI: 10.1002/mrm.1910230204

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  9 in total

1.  Mapping of low flip angles in magnetic resonance.

Authors:  Fabien Balezeau; Pierre-Antoine Eliat; Alejandro Bordelois Cayamo; Hervé Saint-Jalmes
Journal:  Phys Med Biol       Date:  2011-09-23       Impact factor: 3.609

Review 2.  Recent advances in magnetic resonance neurospectroscopy.

Authors:  Yael Rosen; Robert E Lenkinski
Journal:  Neurotherapeutics       Date:  2007-07       Impact factor: 7.620

3.  A novel selective-excitation RF pulse for magnetic resonance imaging.

Authors:  Liu Ying; Li Jianqi; Li Gengying
Journal:  MAGMA       Date:  2008-04-30       Impact factor: 2.310

4.  Correction of parallel transmission using concurrent RF and gradient field monitoring.

Authors:  Mustafa Çavuşoğlu; Benjamin Emanuel Dietrich; David Otto Brunner; Markus Weiger; Klaas Paul Pruessmann
Journal:  MAGMA       Date:  2017-04-25       Impact factor: 2.310

5.  Iterative correction of RF envelope distortion with GRATER-measured waveforms.

Authors:  Vanessa L Landes; Krishna S Nayak
Journal:  Magn Reson Med       Date:  2019-08-23       Impact factor: 4.668

6.  Simple method for RF pulse measurement using gradient reversal.

Authors:  Vanessa L Landes; Krishna S Nayak
Journal:  Magn Reson Med       Date:  2017-09-14       Impact factor: 4.668

7.  Probing the regional distribution of pulmonary gas exchange through single-breath gas- and dissolved-phase 129Xe MR imaging.

Authors:  S Sivaram Kaushik; Matthew S Freeman; Zackary I Cleveland; John Davies; Jane Stiles; Rohan S Virgincar; Scott H Robertson; Mu He; Kevin T Kelly; W Michael Foster; H Page McAdams; Bastiaan Driehuys
Journal:  J Appl Physiol (1985)       Date:  2013-07-11

8.  Mapping of intracellular pH in the in vivo rodent heart using hyperpolarized [1-13C]pyruvate.

Authors:  Angus Z Lau; Jack J Miller; Damian J Tyler
Journal:  Magn Reson Med       Date:  2016-05-13       Impact factor: 4.668

9.  Pulse encoding for ZTE imaging: RF excitation without dead-time penalty.

Authors:  Romain Froidevaux; Markus Weiger; Klaas P Pruessmann
Journal:  Magn Reson Med       Date:  2021-11-14       Impact factor: 3.737

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.