Literature DB >> 15480662

Bone allografting: an Indian experience.

Harish V Kurup1, Prabhakar Rao, Dilip K Patro.   

Abstract

Freeze-drying is considered to be the best technique for allograft preparation and storage. This method is, however, unsuitable for use in developing countries due to high costs. Ethylene oxide sterilization is still controversial because of its effect on osteoinductive capacity. This study involved setting up a bone bank for the first time. Cancellous bone collected from 40 patients was cleaned thoroughly, chemically processed, and sterilized with ethylene oxide gas and stored doubly packed. The grafts were implanted in 11 patients with 14 nonunions. Patients were followed up clinically and radiologically. Thirteen sites were united at the end of 12 months, taking an average of 44.8 weeks to unite. Allograft was also used in 8 benign bone lesions, which showed incorporation of the graft by 29 weeks. This study shows cancellous allograft is suitable for packing cavities in the treatment of benign bone lesions and in treatment of nonunion. There was one deep infection. The low infection rate confirms the efficacy of ethylene oxide as a reliable option for sterilization of bone allograft, and it is also cost effective.

Entities:  

Mesh:

Year:  2004        PMID: 15480662      PMCID: PMC3456901          DOI: 10.1007/s00264-004-0593-7

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  10 in total

1.  A radiological evaluation of allografts (ethylene oxide sterilized cadaver bone) and autografts in anterior cervical fusion.

Authors:  J K B C Parthiban; B K Singhania; P S Ramani
Journal:  Neurol India       Date:  2002-03       Impact factor: 2.117

2.  Clinical evaluation of freeze-dried bone grafts.

Authors:  C R CARR; G W HYATT
Journal:  J Bone Joint Surg Am       Date:  1955-06       Impact factor: 5.284

3.  Massive allografts in surgery of bone tumors.

Authors:  W Mnaymneh; T Malinin
Journal:  Orthop Clin North Am       Date:  1989-07       Impact factor: 2.472

4.  Preparation of bank bone using defatting, freeze-drying and sterilisation with ethylene oxide gas. Part 2. Clinical evaluation of its efficacy and safety.

Authors:  M Kakiuchi; K Ono
Journal:  Int Orthop       Date:  1996       Impact factor: 3.075

5.  Solitary unicameral bone cyst: treatment with freeze-dried crushed cortical-bone allograft. A review of one hundred and forty-four cases.

Authors:  K F Spence; R W Bright; S P Fitzgerald; K W Sell
Journal:  J Bone Joint Surg Am       Date:  1976-07       Impact factor: 5.284

6.  Audit of a bone bank.

Authors:  J P Ivory; I H Thomas
Journal:  J Bone Joint Surg Br       Date:  1993-05

7.  Three years' audit of a bone bank.

Authors:  O Korkala; M Jokinen; A Matikainen
Journal:  Ann Chir Gynaecol       Date:  1994

8.  A study of the clinical incidence of infection in the use of banked allograft bone.

Authors:  W W Tomford; R J Starkweather; M H Goldman
Journal:  J Bone Joint Surg Am       Date:  1981-02       Impact factor: 5.284

9.  Clinical experience with allograft implantation. The first ten years.

Authors:  H J Mankin; S Doppelt; W Tomford
Journal:  Clin Orthop Relat Res       Date:  1983-04       Impact factor: 4.176

10.  Ethylene oxide sterilization impairs allograft incorporation in a conduction chamber.

Authors:  K Thorén; P Aspenberg
Journal:  Clin Orthop Relat Res       Date:  1995-09       Impact factor: 4.176

  10 in total
  2 in total

1.  The contamination of allografts in multi-organ donors: a bone bank experience.

Authors:  Imran Ilays; Shuruq A Alsakran; Abdulelah B Fallatah; Mohammad Alyateem; Omar A Al-Mohrej
Journal:  Cell Tissue Bank       Date:  2021-01-09       Impact factor: 1.522

2.  Principles of bone and tissue banking in Saudi Arabia: 10-year experience report.

Authors:  Imran Ilyas; Anwar M Al-Rabiah; Thamer S Alhussainan; Husam A Alrumaih; Abdulelah B Fallatah; Shuruq A Alsakran; Omar A Al-Mohrej
Journal:  Cell Tissue Bank       Date:  2020-10-04       Impact factor: 1.522

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.