Literature DB >> 15478415

Focused array transducer for two-dimensional optoacoustic tomography.

Victor Kozhushko1, Tanya Khokhlova, Alexei Zharinov, Ivan Pelivanov, Vladimir Solomatin, Alexander Karabutov.   

Abstract

Optoacoustic (OA) imaging utilizes short laser pulses to create acoustic sources in tissue and time resolved detection of generated pressure profiles for image reconstruction. The ultrasonic transients provide information on the distribution of optical absorption coefficient that can be useful for early cancer diagnostics. In this work a new design of wide-band array transducer is developed and tested. The array consists of 32 focused piezo-elements made of PVDF slabs imposed on a cylindrical surface. A single array element response to an OA signal coming from arbitrarily located point source is investigated theoretically and experimentally. The measured signals correspond well to numerically calculated ones. Focal zone maps of the elements with aperture angles 30 degrees and 60 degrees are presented and discussed; the resolution in direction perpendicular to the imaging plane is determined. Point spread function of the whole array is calculated using experimentally obtained signals from the sources located at different distances from the array. Backprojection algorithm is employed for reconstruction of the optoacoustic images. It is shown that the spatial resolution of the images yielded by the proposed array increases significantly compared to previous transducer designs.

Entities:  

Mesh:

Year:  2004        PMID: 15478415     DOI: 10.1121/1.1781710

Source DB:  PubMed          Journal:  J Acoust Soc Am        ISSN: 0001-4966            Impact factor:   1.840


  9 in total

1.  Photoacoustic imaging with a commercial ultrasound system and a custom probe.

Authors:  Xueding Wang; J Brian Fowlkes; Jonathan M Cannata; Changhong Hu; Paul L Carson
Journal:  Ultrasound Med Biol       Date:  2011-01-26       Impact factor: 2.998

2.  Curved array photoacoustic tomographic system for small animal imaging.

Authors:  John Gamelin; Andres Aguirre; Anastasios Maurudis; Fei Huang; Diego Castillo; Lihong V Wang; Quing Zhu
Journal:  J Biomed Opt       Date:  2008 Mar-Apr       Impact factor: 3.170

3.  Photoacoustic tomography of small animal brain with a curved array transducer.

Authors:  Xinmai Yang; Anastasios Maurudis; John Gamelin; Andres Aguirre; Quing Zhu; Lihong V Wang
Journal:  J Biomed Opt       Date:  2009 Sep-Oct       Impact factor: 3.170

Review 4.  Photoacoustic imaging and characterization of the microvasculature.

Authors:  Song Hu; Lihong V Wang
Journal:  J Biomed Opt       Date:  2010 Jan-Feb       Impact factor: 3.170

5.  A new fiber-optic non-contact compact laser-ultrasound scanner for fast non-destructive testing and evaluation of aircraft composites.

Authors:  Ivan Pelivanov; Takashi Buma; Jinjun Xia; Chen-Wei Wei; Matthew O'Donnell
Journal:  J Appl Phys       Date:  2014-03-21       Impact factor: 2.546

6.  Simultaneous photoacoustic and optically mediated ultrasound microscopy: an in vivo study.

Authors:  Pavel Subochev; Anna Orlova; Marina Shirmanova; Anna Postnikova; Ilya Turchin
Journal:  Biomed Opt Express       Date:  2015-01-29       Impact factor: 3.732

7.  Photo-acoustic concave transmitter for generating high frequency focused ultrasound.

Authors:  Hyoung Won Baac; Tao Ling; Shai Ashkenazi; Sheng-Wen Huang; L Jay Guo
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2010-02-11

8.  Coregistered three-dimensional ultrasound and photoacoustic imaging system for ovarian tissue characterization.

Authors:  Andres Aguirre; Puyun Guo; John Gamelin; Shikui Yan; Mary M Sanders; Molly Brewer; Quing Zhu
Journal:  J Biomed Opt       Date:  2009 Sep-Oct       Impact factor: 3.170

9.  A Constrained Variable Projection Reconstruction Method for Photoacoustic Computed Tomography Without Accurate Knowledge of Transducer Responses.

Authors:  Qiwei Sheng; Kun Wang; Thomas P Matthews; Jun Xia; Liren Zhu; Lihong V Wang; Mark A Anastasio
Journal:  IEEE Trans Med Imaging       Date:  2015-12       Impact factor: 10.048

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.