Literature DB >> 15475852

The less invasive stabilization system in the treatment of complex fractures of the tibial plateau: short-term results.

James P Stannard1, Timothy C Wilson, David A Volgas, Jorge E Alonso.   

Abstract

OBJECTIVES: To report on the use of a new plating system in the treatment of high-energy tibial plateau fractures using minimally invasive stabilization techniques.
DESIGN: Prospective, consecutive patient series.
SETTING: University Level I trauma center. PATIENTS: Thirty-seven patients with 39 fractures of the tibial plateau were treated using specialty plates. All fractures were OTA class 41C. Ten of the fractures were open, including eight Gustilo and Anderson Type IIIA and two Type IIIB. Thirty-three patients with 34 fractures had follow-up of at least 12 months. INTERVENTION: Internal fixation with the Less Invasive Stabilization System (LISS, Synthes USA, Paoli, PA) using minimally invasive techniques. MAIN OUTCOME MANAGEMENT: To determine clinical outcome, time to union, fracture alignment, articular step-off, incidence of complications, Short Form-36 outcome scores, and Lysholm knee scores in patients with associated ligament injuries.
RESULTS: All 34 of the fractures healed without additional surgical intervention or bone grafting. The mean follow-up in our series was 21 months, with a range of 12 to 38 months. Twenty-nine patients with 30 fractures had follow-up of greater than 1 year. The average time to radiographic callus was 6.1 weeks, and the average time to complete union was 15.6 weeks. The articular step-off average was 0.8 mm, with a range of 0 to 5 mm. The postoperative alignment demonstrated 1 patient with a malalignment of 5 degrees procurvatum and 1 patient with 4 degrees of valgus. There were two superficial wound infections and no cases of deep infection or osteomyelitis.
CONCLUSIONS: The use of LISS plates appears to stabilize complex fractures of the tibial plateau with a low incidence of complications. The LISS system functioned well in maintaining alignment and obtaining union in these high-energy fractures.

Entities:  

Mesh:

Year:  2004        PMID: 15475852     DOI: 10.1097/00005131-200409000-00012

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  21 in total

Review 1.  Meta-analysis shows that highly comminuted bicondylar tibial plateau fractures treated by single lateral locking plate give similar outcomes as dual plate fixation.

Authors:  Hengrui Chang; Yanbin Zhu; Zhanle Zheng; Wei Chen; Shue Zhao; Yiwen Zhang; Yingze Zhang
Journal:  Int Orthop       Date:  2016-03-23       Impact factor: 3.075

2.  Locking plate in proximal tibial fracture: a correlation between the coronal alignment of tibia and joint screw angle.

Authors:  Jong-Keon Oh; Jin-Ho Hwang; Lalrinliana Varte; Jae-Han Ko; Chang-Wug Oh; Duk-Young Jung; Hyonggin An; Jae-Woo Cho
Journal:  Yonsei Med J       Date:  2013-05-01       Impact factor: 2.759

3.  Comparative study of internal and hybrid external fixation in tibial condylar fractures.

Authors:  A Malakasi; S N Lallos; E Chronopoulos; D S Korres; N E Efstathopoulos
Journal:  Eur J Orthop Surg Traumatol       Date:  2011-11-26

4.  Less invasive stabilization system for the management of proximal tibia fractures.

Authors:  Pramod Devkota; Hemanta K Manandhar; Padam B Khadka; Laxmi P Mainali; Javed A Khan; Balakrishnan M Acharya; Nabeesman S Pradhan; Suman K Shrestha
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-11-20

5.  Proximal tibial fractures: early experience using polyaxial locking-plate technology.

Authors:  Vassilios S Nikolaou; Hiang Boon Tan; George Haidukewych; Nikolaos Kanakaris; Peter V Giannoudis
Journal:  Int Orthop       Date:  2010-11-25       Impact factor: 3.075

6.  Tibial plateau fractures treated with the less invasive stabilisation system.

Authors:  Jackson A Lee; Stamatios A Papadakis; Charles Moon; Charalampos G Zalavras
Journal:  Int Orthop       Date:  2006-07-18       Impact factor: 3.075

Review 7.  Variability in the assessment of fracture-healing in orthopaedic trauma studies.

Authors:  Luis A Corrales; Saam Morshed; Mohit Bhandari; Theodore Miclau
Journal:  J Bone Joint Surg Am       Date:  2008-09       Impact factor: 5.284

8.  [Treatment of complicated proximal segmental tibia fractures with the less invasive stabilization locking plate system].

Authors:  M Beck; G Gradl; P Gierer; R Rotter; M Witt; T Mittlmeier
Journal:  Unfallchirurg       Date:  2008-07       Impact factor: 1.000

Review 9.  High-energy tibial plateau fractures: external fixation versus plate fixation.

Authors:  Liang Yu; Zhong Fenglin
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-09-13

10.  Does prior infection alter the outcome of TKA after tibial plateau fracture?

Authors:  A Noelle Larson; Arlen D Hanssen; Joseph R Cass
Journal:  Clin Orthop Relat Res       Date:  2008-11-12       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.