Literature DB >> 23412414

Comparative study of internal and hybrid external fixation in tibial condylar fractures.

A Malakasi1, S N Lallos, E Chronopoulos, D S Korres, N E Efstathopoulos.   

Abstract

BACKGROUND: The spectrum of injuries to the tibial plateau is so great that no single method of treatment has been proven to be uniformly successful. The purposes of this study were to evaluate the clinical results, to identify the advantages and disadvantages and to take out useful conclusions of the application of the internal and hybrid external fixation in the treatment of these fractures.
METHOD: Sixty tibial condylar fractures, of all types, according to Schatzker's classification were treated with open reduction and internal fixation (30 patients) or with hybrid external fixation (30 patients). The following parameters were recorded: time of surgical procedure, time of postoperative hospitalization, time of starting of weight bearing on the affected extremity, complications, and postoperative functional (according to Knee Society Score) and radiological results (according to Rasmussen's Radiological Score). The average time of follow-up was 12 months.
RESULTS: Neither of the two methods showed superiority regarding the duration of the surgical procedure [mean difference 4.4 ± 5.4 (min), P = NS], the postoperative hospitalization time [0.6 ± 0.7 (days), P = NS], and the radiological and functional evaluation (χ(2), P = NS for all comparisons). However, the internal fixation method proved to be superior to the hybrid external fixation regarding the time of starting the weight bearing [3.1 ± 0.4 (weeks), P < 0.001].
CONCLUSION: Internal fixation showed superiority to the time starting of weight bearing as it occurred at an earlier time than that of hybrid external by almost 3 weeks whereas no other differences were identified in the other parameters regarding patients' rehabilitation.

Entities:  

Mesh:

Year:  2011        PMID: 23412414     DOI: 10.1007/s00590-011-0911-x

Source DB:  PubMed          Journal:  Eur J Orthop Surg Traumatol        ISSN: 1633-8065


  23 in total

1.  Treatment of complex (Schatzker Type VI) fractures of the tibial plateau with circular wire external fixation: retrospective case review.

Authors:  A Kumar; A P Whittle
Journal:  J Orthop Trauma       Date:  2000 Jun-Jul       Impact factor: 2.512

2.  Bicondylar tibial plateau fractures managed with the Sheffield Hybrid Fixator. Biomechanical study and operative technique.

Authors:  A M Ali; L Yang; M Hashmi; M Saleh
Journal:  Injury       Date:  2001-12       Impact factor: 2.586

3.  Single lateral locked screw plating of bicondylar tibial plateau fractures.

Authors:  T Gosling; P Schandelmaier; M Muller; S Hankemeier; M Wagner; C Krettek
Journal:  Clin Orthop Relat Res       Date:  2005-10       Impact factor: 4.176

4.  Treatment of high-energy proximal tibial fractures using the Monticelli-Spinelli external fixator: a preliminary report.

Authors:  S B Zecher; M B Danziger; D Segal; T Foster; G P Whitelaw; D J Covall
Journal:  Am J Orthop (Belle Mead NJ)       Date:  1996-01

5.  Tibial condylar fractures. Impairment of knee joint stability as an indication for surgical treatment.

Authors:  P S Rasmussen
Journal:  J Bone Joint Surg Am       Date:  1973-10       Impact factor: 5.284

6.  Stabilization of proximal tibial fractures with the LIS-System: early clinical experience in Berlin.

Authors:  M Schütz; M J Kääb; N Haas
Journal:  Injury       Date:  2003-08       Impact factor: 2.586

Review 7.  High-energy fractures of the tibial plateau.

Authors:  J T Watson
Journal:  Orthop Clin North Am       Date:  1994-10       Impact factor: 2.472

8.  The less invasive stabilization system in the treatment of complex fractures of the tibial plateau: short-term results.

Authors:  James P Stannard; Timothy C Wilson; David A Volgas; Jorge E Alonso
Journal:  J Orthop Trauma       Date:  2004-09       Impact factor: 2.512

9.  Open reduction and internal fixation compared with circular fixator application for bicondylar tibial plateau fractures. Surgical technique.

Authors:  Jeremy A Hall; Murray J Beuerlein; Michael D McKee
Journal:  J Bone Joint Surg Am       Date:  2009-03-01       Impact factor: 5.284

10.  Bicondylar tibial fractures: Internal or external fixation?

Authors:  Gunasekaran Kumar; Nicholas Peterson; Badri Narayan
Journal:  Indian J Orthop       Date:  2011-03       Impact factor: 1.251

View more
  6 in total

1.  Post-operative complications of tibial plateau fractures treated with screws or hybrid external fixation.

Authors:  F Stefanelli; I Cucurnia; A Grassi; N Pizza; S Di Paolo; M Casali; F Raggi; M Romagnoli; S Zaffagnini
Journal:  Musculoskelet Surg       Date:  2021-08-03

Review 2.  Surgical fixation methods for tibial plateau fractures.

Authors:  Iain R McNamara; Toby O Smith; Karen L Shepherd; Allan B Clark; Dominic M Nielsen; Simon Donell; Caroline B Hing
Journal:  Cochrane Database Syst Rev       Date:  2015-09-15

3.  Autograft transfer from the ipsilateral femoral condyle in depressed tibial plateau fractures.

Authors:  N K Sferopoulos
Journal:  Open Orthop J       Date:  2014-09-30

Review 4.  A Meta-analysis Comparing External Fixation against Open Reduction and Internal Fixation for the Management of Tibial Plateau Fractures.

Authors:  Ahmad S Naja; Nour Bouji; Mohamad Nasser Eddine; Humaid Alfarii; Rudolf Reindl; Yehia Tfayli; Mohamad Issa; Said Saghieh
Journal:  Strategies Trauma Limb Reconstr       Date:  2022 May-Aug

Review 5.  Complications of the surgical treatment of fractures of the tibial plateau: prevalence, causes, and management.

Authors:  Elena Gálvez-Sirvent; Aitor Ibarzábal-Gil; E Carlos Rodríguez-Merchán
Journal:  EFORT Open Rev       Date:  2022-08-04

6.  The distal femur is a reliable guide for tibial plateau fracture reduction: a study of measurements on 3D CT scans in 84 healthy knees.

Authors:  Sorawut Thamyongkit; Laura M Fayad; Lynne C Jones; Erik A Hasenboehler; Norachart Sirisreetreerux; Babar Shafiq
Journal:  J Orthop Surg Res       Date:  2018-09-04       Impact factor: 2.359

  6 in total