A constrained liner cemented into a secure cementless acetabular shell.

John J Callaghan1, Javad Parvizi, Clifford C Novak, Barron Bremner, Wade Shrader, David G Lewallen, Richard C Johnston, Devon D Goetz.   

Abstract

BACKGROUND: Constrained acetabular components have been used to treat hips with recurrent instability following total hip arthroplasty and hips that demonstrate instability during revision surgery. In such hips, when a secure cementless acetabular shell is present, the surgeon can cement a constrained liner into the existing shell. The purpose of this study was to evaluate the clinical and radiographic outcome of this technique with use of a tripolar constrained liner that was cemented into a well-fixed cementless acetabular shell.
METHODS: Between 1988 and 2000, constrained liners were cemented into thirty-one well-fixed cementless acetabular shells at three centers. The average age of the patients at the time of the index surgery was 72.1 years, and the indications for the procedure were recurrent hip instability in sixteen hips and intraoperative instability in fifteen hips. The patients were evaluated with respect to the clinical outcome and radiographic evidence of shell loosening and osteolysis.
RESULTS: At an average duration of follow-up of 3.9 years, twenty-nine liners (94%) were securely fixed in the cementless shells and two constrained liners had failed. One liner failed because it separated from the cement, and one failed because of fracture of the capturing mechanism. Both hips were successfully revised with another cemented tripolar constrained liner. No acetabular component demonstrated radiographic evidence of progressive loosening or osteolysis.
CONCLUSIONS: A constrained tripolar liner cemented into a secure, well-positioned cementless acetabular shell provides stability and durability at short-term follow-up. Careful attention to the preparation of the liner, the sizing of the component, and the cementing technique are likely to reduce the failure of this construct, which can be used for difficult cases of total hip instability.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15466729     DOI: 10.2106/00004623-200410000-00011

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  16 in total

Review 1.  [Partial exchange in total hip arthroplasty : What can we combine?]

Authors:  P Weber; A Steinbrück; A C Paulus; M Woiczinski; F Schmidutz; A Fottner; V Jansson
Journal:  Orthopade       Date:  2017-02       Impact factor: 1.087

2.  Cementing acetabular liners into secure cementless shells for polyethylene wear provides durable mid-term fixation.

Authors:  John J Callaghan; David W Hennessy; Steve S Liu; Kirsten E Goetz; Anneliese D Heiner
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

3.  Are abductor muscle quality and previous revision surgery predictors of constrained liner failure in hip arthroplasty?

Authors:  Michael G Zywiel; Loi'y H Mustafa; Peter M Bonutti; Michael A Mont
Journal:  Int Orthop       Date:  2010-02-20       Impact factor: 3.075

Review 4.  Impingement and dislocation in total hip arthroplasty: mechanisms and consequences.

Authors:  Thomas D Brown; Jacob M Elkins; Douglas R Pedersen; John J Callaghan
Journal:  Iowa Orthop J       Date:  2014

Review 5.  [Hip dislocation after revision arthroplasty : Risk assessment and treatment strategies].

Authors:  P M Prodinger; J Schauwecker; H Mühlhofer; N Harrasser; F Pohlig; C Suren; R von Eisenhart-Rothe
Journal:  Orthopade       Date:  2017-02       Impact factor: 1.087

6.  Instability after total hip arthroplasty.

Authors:  Brian C Werner; Thomas E Brown
Journal:  World J Orthop       Date:  2012-08-18

Review 7.  Constrained components for the unstable hip following total hip arthroplasty: a literature review.

Authors:  J T Williams; P S Ragland; S Clarke
Journal:  Int Orthop       Date:  2006-08-23       Impact factor: 3.075

Review 8.  Total hip arthroplasty instability in Italy.

Authors:  Francesco Falez; Matteo Papalia; Fabio Favetti; Gabriele Panegrossi; Filippo Casella; Gianluca Mazzotta
Journal:  Int Orthop       Date:  2016-12-20       Impact factor: 3.075

9.  The unstable total hip replacement.

Authors:  F D'Angelo; L Murena; G Zatti; P Cherubino
Journal:  Indian J Orthop       Date:  2008-07       Impact factor: 1.251

Review 10.  Risk of revision and dislocation in single, dual mobility and large femoral head total hip arthroplasty: systematic review and network meta-analysis.

Authors:  Kwanchai Pituckanotai; Alisara Arirachakaran; Harit Tuchinda; Chinundorn Putananon; Nitiphol Nualsalee; Kittipong Setrkraising; Jatupon Kongtharvonskul
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-11-08
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.