Literature DB >> 15466635

Heparin and air filters reduce embolic events caused by intra-arterial cerebral angiography: a prospective, randomized trial.

Martin Bendszus1, Martin Koltzenburg, Andreas J Bartsch, Roland Goldbrunner, Thomas Günthner-Lengsfeld, Franz X Weilbach, Klaus Roosen, Klaus V Toyka, László Solymosi.   

Abstract

BACKGROUND: Intra-arterial cerebral angiography is associated with a low risk for neurological complications, but clinically silent ischemic events after angiography have been seen in a substantial number of patients. METHODS AND
RESULTS: In a prospective study, diffusion-weighted magnetic resonance imaging (DW-MRI) before and after intra-arterial cerebral angiography and transcranial Doppler sonography during angiography were used to evaluate the frequency of cerebral embolism. One hundred fifty diagnostic cerebral angiographies were randomized into 50 procedures, each using conventional angiographic technique, or systemic heparin treatment throughout the procedure, or air filters between the catheter and both the contrast medium syringe and the catheter flushing. There was no neurological complication during or after angiography. Overall, DW-MRI revealed 26 new ischemic lesions in 17 patients (11%). In the control group, 11 patients showed a total of 18 lesions. In the heparin group, 3 patients showed a total of 4 lesions. In the air filter group, 3 patients exhibited a total of 4 lesions. The reduced incidence of ischemic events in the heparin and air filter groups compared with the control group was significantly different (P=0.002). Transcranial Doppler sonography demonstrated a large number of microembolic signals that was significantly lower in the air filter group compared with the heparin and control groups (P<0.01), which did not differ from each other.
CONCLUSIONS: Air filters and heparin both reduce the incidence of silent ischemic events detected by DW-MRI after intra-arterial cerebral angiography and can potentially lower clinically overt ischemic complications. This may apply to any intra-arterial angiographic procedure.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15466635     DOI: 10.1161/01.CIR.0000144301.82391.85

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  20 in total

1.  In vitro observation of air bubbles during delivery of various detachable aneurysm embolization coils.

Authors:  Deok Hee Lee; Seon Moon Hwang; Ok Kyun Lim; Jae Kyun Kim
Journal:  Korean J Radiol       Date:  2012-06-18       Impact factor: 3.500

2.  Diffusion-weighted MR imaging lesions after filter-protected stenting of high-grade symptomatic carotid artery stenoses.

Authors:  R du Mesnil de Rochemont; S Schneider; B Yan; A Lehr; M Sitzer; J Berkefeld
Journal:  AJNR Am J Neuroradiol       Date:  2006 Jun-Jul       Impact factor: 3.825

3.  Occlusion of the middle cerebral artery due to synthetic fibers.

Authors:  R Chapot; M Wassef; A Bisdorff; A Rogopoulos; J-J Merland; E Houdart
Journal:  AJNR Am J Neuroradiol       Date:  2006-01       Impact factor: 3.825

Review 4.  Targeting the brain: rationalizing the novel methods of drug delivery to the central nervous system.

Authors:  Shailendra Joshi; Eugene Ornstein; Jeffrey N Bruce
Journal:  Neurocrit Care       Date:  2007       Impact factor: 3.210

5.  The influence of carotid artery catheterization technique on the incidence of thromboembolism during carotid artery stenting.

Authors:  H J Kim; H J Lee; J H Yang; I S Yeo; J S Yi; I W Lee; S B Lee; S Y Ryu; J K Kim; P S Yang
Journal:  AJNR Am J Neuroradiol       Date:  2010-07-01       Impact factor: 3.825

6.  Acetylsalicylic acid does not prevent digital subtraction angiography-related high signal intensity lesions in diffusion-weighted imaging in cerebrovascular patients. A retrospective analysis.

Authors:  C Brockmann; F Seker; C Weiss; C Groden; J Scharf
Journal:  Clin Neuroradiol       Date:  2011-05-25       Impact factor: 3.649

7.  Endovascular treatment of extracranial vertebral artery stenosis.

Authors:  Burak Kocak; Bora Korkmazer; Civan Islak; Naci Kocer; Osman Kizilkilic
Journal:  World J Radiol       Date:  2012-09-28

8.  Silent microemboli related to diagnostic cerebral angiography: a matter of operator's experience and patient's disease.

Authors:  T Krings; K Willmes; R Becker; I G Meister; F J Hans; M H T Reinges; M Mull; A Thron
Journal:  Neuroradiology       Date:  2006-04-04       Impact factor: 2.804

9.  Prospective Study of Early MRI Appearances following Flow-Diverting Stent Placement for Intracranial Aneurysms.

Authors:  B J McGuinness; S Memon; J K Hope
Journal:  AJNR Am J Neuroradiol       Date:  2015-03-12       Impact factor: 3.825

10.  Symptomatic cerebral air embolism during neuro-angiographic procedures: incidence and problem avoidance.

Authors:  Rishi Gupta; Nirav Vora; Ajith Thomas; Donald Crammond; Ronald Roth; Tudor Jovin; Michael Horowitz
Journal:  Neurocrit Care       Date:  2007       Impact factor: 3.210