R Chapot1, M Wassef, A Bisdorff, A Rogopoulos, J-J Merland, E Houdart.
Abstract
We report an unusual etiology for a thromboembolic complication. Occlusion of the middle cerebral artery occurred before embolization of an intracranial aneurysm. Attempts to recanalize the artery failed by using both fibrinolytics and IIb/IIIa inhibitors but succeeded with mechanical thrombectomy with a micro-snare. Pathologic analysis of the thrombus showed numerous synthetic fibers that were determined to have originated from unsealed gauze that was used during the procedure.Entities:
Mesh:
Year: 2006 PMID: 16418375 PMCID: PMC7976100
Source DB: PubMed Journal: AJNR Am J Neuroradiol ISSN: 0195-6108 Impact factor: 3.825