Literature DB >> 15465354

Charge competition and the linear dynamic range of detection in electrospray ionization mass spectrometry.

Keqi Tang1, Jason S Page1, Richard D Smith2.   

Abstract

An experimental investigation and theoretical analysis are reported on charge competition in electrospray ionization (ESI) and its effects on the linear dynamic range of ESI mass spectrometric (MS) measurements. The experiments confirmed the expected increase of MS sensitivities as the ESI flow rate decreases. However, different compounds show somewhat different mass spectral peak intensities even at the lowest flow rates, at the same concentration and electrospray operating conditions. MS response for each compound solution shows good linearity at lower concentrations and levels off at high concentration, consistent with analyte "saturation" in the ESI process. The extent of charge competition leading to saturation in the ESI process is consistent with the relative magnitude of excess charge in the electrospray compared to the total number of analyte molecules in the solution. This ESI capacity model allows one to predict the sample concentration limits for charge competition and the on-set of ionization suppression effects, as well as the linear dynamic range for ESI-MS. The implications for quantitative MS analysis and possibilities for effectively extending the dynamic range of ESI measurements are discussed.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15465354      PMCID: PMC1829300          DOI: 10.1016/j.jasms.2004.04.034

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  14 in total

1.  Nanoelectrospray--more than just a minimized-flow electrospray ionization source.

Authors:  R Juraschek; T Dülcks; M Karas
Journal:  J Am Soc Mass Spectrom       Date:  1999-04       Impact factor: 3.109

2.  Relating electrospray ionization response to nonpolar character of small peptides.

Authors:  N B Cech; C G Enke
Journal:  Anal Chem       Date:  2000-07-01       Impact factor: 6.986

3.  Independent control of ion transmission in a jet disrupter dual-channel ion funnel electrospray ionization MS interface.

Authors:  Keqi Tang; Aleksey V Tolmachev; Evgueni Nikolaev; Rui Zhang; Mikhail E Belov; Harold R Udseth; Richard D Smith
Journal:  Anal Chem       Date:  2002-10-15       Impact factor: 6.986

4.  Ultrasensitive proteomics using high-efficiency on-line micro-SPE-nanoLC-nanoESI MS and MS/MS.

Authors:  Yufeng Shen; Nikola Tolić; Christophe Masselon; Ljiljana Pasa-Tolić; David G Camp; Kim K Hixson; Rui Zhao; Gordon A Anderson; Richard D Smith
Journal:  Anal Chem       Date:  2004-01-01       Impact factor: 6.986

5.  Effect of different solution flow rates on analyte ion signals in nano-ESI MS, or: when does ESI turn into nano-ESI?

Authors:  Andrea Schmidt; Michael Karas; Thomas Dülcks
Journal:  J Am Soc Mass Spectrom       Date:  2003-05       Impact factor: 3.109

6.  Advantages and drawbacks of nanospray for studying noncovalent protein-DNA complexes by mass spectrometry.

Authors:  Valérie Gabelica; Christelle Vreuls; Patrice Filée; Valérie Duval; Bernard Joris; Edwin De Pauw
Journal:  Rapid Commun Mass Spectrom       Date:  2002       Impact factor: 2.419

Review 7.  Ultrasensitive and quantitative analyses from combined separations-mass spectrometry for the characterization of proteomes.

Authors:  Richard D Smith; Yufeng Shen; Keqi Tang
Journal:  Acc Chem Res       Date:  2004-04       Impact factor: 22.384

8.  A predictive model for matrix and analyte effects in electrospray ionization of singly-charged ionic analytes.

Authors:  C G Enke
Journal:  Anal Chem       Date:  1997-12-01       Impact factor: 6.986

9.  Analytical properties of the nanoelectrospray ion source.

Authors:  M Wilm; M Mann
Journal:  Anal Chem       Date:  1996-01-01       Impact factor: 6.986

10.  Physical/chemical separations in the break-up of highly charged droplets from electrosprays.

Authors:  K Tang; R D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2001-03       Impact factor: 3.262

View more
  52 in total

1.  A study of electrospray ionization emitters with differing geometries with respect to flow rate and electrospray voltage.

Authors:  Brent R Reschke; Aaron T Timperman
Journal:  J Am Soc Mass Spectrom       Date:  2011-10-12       Impact factor: 3.109

2.  Direct detection of pharmaceuticals and personal care products from aqueous samples with thermally-assisted desorption electrospray ionization mass spectrometry.

Authors:  Ian S Campbell; Alain T Ton; Christopher C Mulligan
Journal:  J Am Soc Mass Spectrom       Date:  2011-05-05       Impact factor: 3.109

3.  Differential Mobility Spectrometry-Mass Spectrometry (DMS-MS) in Radiation Biodosimetry: Rapid and High-Throughput Quantitation of Multiple Radiation Biomarkers in Nonhuman Primate Urine.

Authors:  Zhidan Chen; Stephen L Coy; Evan L Pannkuk; Evagelia C Laiakis; Albert J Fornace; Paul Vouros
Journal:  J Am Soc Mass Spectrom       Date:  2018-05-07       Impact factor: 3.109

4.  Optimization of the design and operation of FAIMS analyzers.

Authors:  Alexandre A Shvartsburg; Keqi Tang; Richard D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2005-01       Impact factor: 3.109

5.  High-sensitivity ion mobility spectrometry/mass spectrometry using electrodynamic ion funnel interfaces.

Authors:  Keqi Tang; Alexandre A Shvartsburg; Hak-No Lee; David C Prior; Michael A Buschbach; Fumin Li; Aleksey V Tolmachev; Gordon A Anderson; Richard D Smith
Journal:  Anal Chem       Date:  2005-05-15       Impact factor: 6.986

Review 6.  Advances and challenges in liquid chromatography-mass spectrometry-based proteomics profiling for clinical applications.

Authors:  Wei-Jun Qian; Jon M Jacobs; Tao Liu; David G Camp; Richard D Smith
Journal:  Mol Cell Proteomics       Date:  2006-08-03       Impact factor: 5.911

7.  Normalization approaches for removing systematic biases associated with mass spectrometry and label-free proteomics.

Authors:  Stephen J Callister; Richard C Barry; Joshua N Adkins; Ethan T Johnson; Wei-Jun Qian; Bobbie-Jo M Webb-Robertson; Richard D Smith; Mary S Lipton
Journal:  J Proteome Res       Date:  2006-02       Impact factor: 4.466

8.  Dynamic range of mass accuracy in LTQ Orbitrap hybrid mass spectrometer.

Authors:  Alexander Makarov; Eduard Denisov; Oliver Lange; Stevan Horning
Journal:  J Am Soc Mass Spectrom       Date:  2006-06-05       Impact factor: 3.109

9.  Chemically etched open tubular and monolithic emitters for nanoelectrospray ionization mass spectrometry.

Authors:  Ryan T Kelly; Jason S Page; Quanzhou Luo; Ronald J Moore; Daniel J Orton; Keqi Tang; Richard D Smith
Journal:  Anal Chem       Date:  2006-11-15       Impact factor: 6.986

10.  Quantitative peptidomics for discovery of circadian-related peptides from the rat suprachiasmatic nucleus.

Authors:  Ji Eun Lee; Leonid Zamdborg; Bruce R Southey; Norman Atkins; Jennifer W Mitchell; Mingxi Li; Martha U Gillette; Neil L Kelleher; Jonathan V Sweedler
Journal:  J Proteome Res       Date:  2013-01-11       Impact factor: 4.466

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.