Literature DB >> 15459146

Bench testing of auto-adjusting positive airway pressure devices.

F Abdenbi1, B Chambille, P Escourrou.   

Abstract

Continuous positive airway pressure devices are routinely used to treat sleep breathing disorders. Automated devices that adjust the therapeutic pressure have recently been proposed. The utility of such devices is still controversial, as rigorous clinical comparisons are difficult to perform as a result of patient and device differences. The current authors studied automated devices in a respiratory model that was able to mimic upper airway mechanics and to interact with pressure adjustment in a closed loop. Five auto-adjusted devices were submitted to this model, in order to determine their ability to detect respiratory events and adjust pressure accordingly. All apnoeas were suppressed, whilst the reaction to repetitive hypopnoeas was dependent on the airflow shape. In some devices, repetitive hypopnoeas were changed to flow limitation. Artificial snoring caused a pressure increase in four devices, and constant mask leak was not systematically compensated. Only one device did not raise pressure in response to central apnoeas with opened upper airways. These findings show that, in some devices, event classification failed and normal airflow was not fully restored, resulting in elevated residual event indices. In conclusion, this model is useful in order to reproducibly compare diagnostic and therapeutic capacities of commercial devices as a first step, before costly clinical studies.

Entities:  

Mesh:

Year:  2004        PMID: 15459146     DOI: 10.1183/09031936.04.00133703

Source DB:  PubMed          Journal:  Eur Respir J        ISSN: 0903-1936            Impact factor:   16.671


  11 in total

1.  Bench test evaluation of adaptive servoventilation devices for sleep apnea treatment.

Authors:  Kaixian Zhu; Haissam Kharboutly; Jianting Ma; Mourad Bouzit; Pierre Escourrou
Journal:  J Clin Sleep Med       Date:  2013-09-15       Impact factor: 4.062

2.  Randomised short-term trial of high-span versus low-span APAP for treating sleep apnoea.

Authors:  Helder Novais Bastos; Ana Verónica Cardoso; Ana Sofia Castro; Rita Gomes; Tiago Pinto; Anabela Marinho; Maria Sucena; João Almeida; Marta Drummond; João Carlos Winck
Journal:  Sleep Breath       Date:  2015-06-12       Impact factor: 2.816

3.  Auto bi-level pressure relief-PAP is as effective as CPAP in OSA patients--a pilot study.

Authors:  Alexander Blau; Mihaela Minx; Jan Giso Peter; Martin Glos; Thomas Penzel; Gert Baumann; Ingo Fietze
Journal:  Sleep Breath       Date:  2011-08-27       Impact factor: 2.816

Review 4.  APAP, BPAP, CPAP, and New Modes of Positive Airway Pressure Therapy.

Authors:  Karin G Johnson
Journal:  Adv Exp Med Biol       Date:  2022       Impact factor: 3.650

5.  All APAPs Are Not Equivalent for the Treatment of Sleep Disordered Breathing: A Bench Evaluation of Eleven Commercially Available Devices.

Authors:  Kaixian Zhu; Gabriel Roisman; Sami Aouf; Pierre Escourrou
Journal:  J Clin Sleep Med       Date:  2015-07-15       Impact factor: 4.062

6.  Pressure-Relief Features of Fixed and Autotitrating Continuous Positive Airway Pressure May Impair Their Efficacy: Evaluation with a Respiratory Bench Model.

Authors:  Kaixian Zhu; Sami Aouf; Gabriel Roisman; Pierre Escourrou
Journal:  J Clin Sleep Med       Date:  2016-03       Impact factor: 4.062

Review 7.  Adherence to continuous positive airway pressure therapy: the challenge to effective treatment.

Authors:  Terri E Weaver; Ronald R Grunstein
Journal:  Proc Am Thorac Soc       Date:  2008-02-15

Review 8.  Technology for noninvasive mechanical ventilation: looking into the black box.

Authors:  Ramon Farré; Daniel Navajas; Josep M Montserrat
Journal:  ERJ Open Res       Date:  2016-03-11

9.  Comparative assessment of several automatic CPAP devices' responses: a bench test study.

Authors:  Valentina Isetta; Daniel Navajas; Josep M Montserrat; Ramon Farré
Journal:  ERJ Open Res       Date:  2015-08-21

10.  Reliability of home CPAP titration with different automatic CPAP devices.

Authors:  Frédéric Sériès; Julie Plante; Yves Lacasse
Journal:  Respir Res       Date:  2008-07-24
View more