Literature DB >> 15448482

Structural analysis of the cornea using scanning-slit corneal topography in eyes undergoing excimer laser refractive surgery.

Kazutaka Kamiya1, Kazunori Miyata, Tadatoshi Tokunaga, Takahiro Kiuchi, Takahiro Hiraoka, Tetsuro Oshika.   

Abstract

PURPOSE: To review the time course of corneal anteroposterior shift and refractive stability after myopic excimer laser keratorefractive surgery.
METHODS: We examined 65 eyes undergoing photorefractive keratectomy (PRK) and 45 eyes undergoing laser in situ keratomileusis (LASIK). Corneal elevation maps and pachymetry were obtained by scanning-slit corneal topography before; 1 week; and 1, 3, 6, and 12 months after surgery.
RESULTS: Both PRK and LASIK induced significant forward shifts of the cornea. Corneal forward shift was progressive up to 6 months after PRK, but no progression was seen after LASIK. Progressive thinning and expansion of the cornea were not observed after either procedure. The amount of corneal forward shift showed a significant negative correlation with preoperative corneal thickness (r = -0.586; P < 0.01) and a significant positive correlation with the amount of myopic correction (r = 0.504; P < 0.01). A significant correlation was found between the amount of forward shift and the degree of myopic regression after surgery (r = -0.347; P < 0.05).
CONCLUSION: Myopic PRK and LASIK induce significant forward shifts of the cornea, which are not true corneal ectasia. Eyes with thinner corneas and higher myopia requiring greater ablation are more predisposed to anterior protrusion of the cornea. Corneal forward shift was progressive up to 6 months after PRK but not progressive after LASIK. Forward shift of the cornea can be one of the factors responsible for myopic regression after surgery.

Entities:  

Mesh:

Year:  2004        PMID: 15448482     DOI: 10.1097/01.ico.0000136673.35530.e3

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  10 in total

1.  The change in internal aberrations following myopic corneal laser refractive surgery.

Authors:  Colm McAlinden; Jonathan E Moore
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-07-31       Impact factor: 3.117

2.  Ten-year follow-up of photorefractive keratectomy for myopia.

Authors:  Junko Koshimizu; Raksha Dhanuka; Tatsuo Yamaguchi
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-03-19       Impact factor: 3.117

3.  Comparison of central corneal thickness measurements by Orbscan II and Pentacam after corneal refractive surgery.

Authors:  Jumpei Matsuda; Osamu Hieda; Shigeru Kinoshita
Journal:  Jpn J Ophthalmol       Date:  2008-09-05       Impact factor: 2.447

4.  Predictors affecting myopic regression in - 6.0D to - 10.0D myopia after laser-assisted subepithelial keratomileusis and laser in situ keratomileusis flap creation with femtosecond laser-assisted or mechanical microkeratome-assisted.

Authors:  Jihong Zhou; Wei Gu; Shaowei Li; Lijuan Wu; Yan Gao; Xiuhua Guo
Journal:  Int Ophthalmol       Date:  2019-09-30       Impact factor: 2.031

5.  Factors affecting corneal hysteresis in normal eyes.

Authors:  Kazutaka Kamiya; Mana Hagishima; Fusako Fujimura; Kimiya Shimizu
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2008-06-11       Impact factor: 3.117

6.  Twelve-Year Follow-Up of Laser In Situ Keratomileusis for Moderate to High Myopia.

Authors:  Tetsuya Ikeda; Kimiya Shimizu; Akihito Igarashi; Sumie Kasahara; Kazutaka Kamiya
Journal:  Biomed Res Int       Date:  2017-05-17       Impact factor: 3.411

7.  Normative values and contralateral comparison of anterior chamber parameters measured by Pentacam and its correlation with corneal biomechanical factors.

Authors:  Mohammad Reza Sedaghat; Vahid Mohammad Zadeh; Kaveh Fadakar; Sakineh Kadivar; Mojtaba Abrishami
Journal:  Saudi J Ophthalmol       Date:  2016-12-01

8.  The corneal volume and biomechanical corneal factors: Is there any orrelation?

Authors:  Mohammad Reza Sedaghat; Maria Sharepoor; Samira Hassanzadeh; Mojtaba Abrishami
Journal:  J Res Med Sci       Date:  2012-01       Impact factor: 1.852

9.  Corneal biomechanics in iatrogenic ectasia and keratoconus: A review of the literature.

Authors:  Majid Moshirfar; Jason N Edmonds; Nicholas L Behunin; Steven M Christiansen
Journal:  Oman J Ophthalmol       Date:  2013-01

Review 10.  Efficacy and Safety of Topical Timolol Eye Drops in the Treatment of Myopic Regression after Laser In Situ Keratomileusis: A Systematic Review and Meta-Analysis.

Authors:  Xiaochen Wang; Guiqiu Zhao; Jing Lin; Nan Jiang; Qian Wang; Qiang Xu
Journal:  J Ophthalmol       Date:  2015-12-21       Impact factor: 1.909

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.