Literature DB >> 15448446

Biomechanical comparison of sacroiliac screw techniques for unstable pelvic ring fractures.

C M A van Zwienen1, E W van den Bosch, C J Snijders, G J Kleinrensink, A B van Vugt.   

Abstract

OBJECTIVE: To determine the stiffness and strength of various sacroiliac screw fixations to compare different sacroiliac screw techniques.
DESIGN: Randomized comparative study on embalmed human pelvises.
MATERIALS AND METHODS: In 12 specimens, we created a symphysiolysis and sacral fractures on both sides. Each of these 24 sacral fractures was fixed with 1 of the following methods: 1 sacroiliac screw in the vertebral body of S1, 2 screws convergingly in S1, or 1 screw in S1 and 1 in S2. On the left and right side of a pelvis, different techniques were used. The pubic symphysis was not stabilized. We measured the translation and rotation stiffness of the fixations and the load to failure using a 3-dimensional video system.
RESULTS: The stiffness of the intact posterior pelvic ring was superior to any screw technique. Significant differences were found for the load to failure and rotation stiffness between the techniques with 2 screws and a single screw in S1. The techniques utilizing 2 screws showed no differences.
CONCLUSIONS: Based on the results of this study, we can conclude that a second sacroiliac screw in completely unstable pelvic fractures increases rotation stiffness and improves the load to failure. Copyright 2004 Lippincott Williams & Wilkins

Entities:  

Mesh:

Year:  2004        PMID: 15448446     DOI: 10.1097/00005131-200410000-00002

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  45 in total

1.  Analysis of sacro-iliac joint screw fixation: does quality of reduction and screw orientation influence joint stability? A biomechanical study.

Authors:  Gaston Camino Willhuber; Ivan Zderic; Florian Gras; Dieter Wahl; Carlos Sancineto; Jorge Barla; Markus Windolf; Robert Geoff Richards; Boyko Gueorguiev
Journal:  Int Orthop       Date:  2015-10-05       Impact factor: 3.075

2.  Parameters of lengthened sacroiliac screw fixation: a radiological anatomy study.

Authors:  Yong Zhao; Jianmin Li; Dan Wang; Wei Lian
Journal:  Eur Spine J       Date:  2012-05-18       Impact factor: 3.134

3.  Biomechanical evaluation of supplemental percutaneous lumbo-sacro-iliac screws for spinopelvic fixation following total sacrectomy.

Authors:  Vu H Le; Nathanael Heckmann; Nickul Jain; Lawrence Wang; Alexander W L Turner; Thay Q Lee; S Samuel Bederman
Journal:  J Spinal Disord Tech       Date:  2015-05

4.  Biomechanical comparison of three types of internal fixation in a type C zone II pelvic fracture model.

Authors:  Tao Wu; Wei Chen; Xu Li; Qi Zhang; Hong-Zhi Lv; Ying-Ze Zhang
Journal:  Int J Clin Exp Med       Date:  2015-02-15

5.  Triangular Titanium Implants for Minimally Invasive Sacroiliac Joint Fusion: 2-Year Follow-Up from a Prospective Multicenter Trial.

Authors:  Bradley S Duhon; Fabien Bitan; Harry Lockstadt; Don Kovalsky; Daniel Cher; Travis Hillen
Journal:  Int J Spine Surg       Date:  2016-04-20

6.  Biomechanical analysis of a transiliac internal fixator.

Authors:  Thomas Dienstknecht; Arne Berner; Andreas Lenich; Johannes Zellner; Michael Mueller; Michael Nerlich; Bernd Fuechtmeier
Journal:  Int Orthop       Date:  2011-04-08       Impact factor: 3.075

7.  Evaluation of 2D and 3D navigation for iliosacral screw fixation.

Authors:  Daniel Behrendt; Maria Mütze; Hanno Steinke; Martin Koestler; Christoph Josten; Jörg Böhme
Journal:  Int J Comput Assist Radiol Surg       Date:  2011-09-18       Impact factor: 2.924

8.  Functional outcome of unstable pelvic ring injuries after iliosacral screw fixation: single versus two screw fixation.

Authors:  S A Khaled; O Soliman; M A Wahed
Journal:  Eur J Trauma Emerg Surg       Date:  2014-10-21       Impact factor: 3.693

9.  Anterior internal fixator versus a femoral distractor and external fixation for sacroiliac joint compression and single stance gait testing: a mechanical study in synthetic bone.

Authors:  Jonathan M Vigdorchik; Amanda O Esquivel; Xin Jin; King H Yang; Rahul Vaidya
Journal:  Int Orthop       Date:  2013-05-04       Impact factor: 3.075

10.  Finite Element Analysis of Sacroiliac Joint Fixation under Compression Loads.

Authors:  Claire Bruna-Rosso; Pierre-Jean Arnoux; Rohan-Jean Bianco; Yves Godio-Raboutet; Léo Fradet; Carl-Éric Aubin