PURPOSE: To facilitate assessing brain tumor growth and progression of stroke lesions by reproducible slice positioning in human head magnetic resonance (MR) images, a method for prospective registration is proposed that adjusts the image slice position without moving the patient and with no additional scans. MATERIALS AND METHODS: The gradient reference frame of follow-up examinations was adjusted to achieve the same image slice positioning relative to the patient as in the previous examination. The three-dimensional geometrical transformation parameters for the gradients were determined using two-dimensional image registration of three orthogonal localizer images. The method was developed and evaluated using a phantom with arbitrarily adjustable position. Feasibility for in vivo applications was demonstrated with brain MR imaging (MRI) of healthy volunteers. RESULTS: Standard retrospective registration was used for assessing the quality of the method. The accuracy of the realignment was 0.0 mm +/- 1.2 mm and -0.2 degrees +/- 0.9 degrees (mean +/- SD) in phantom experiments. In 10 examinations of volunteers, misalignments up to 49.2 mm and 21 degrees were corrected. The accuracy of the realignment after prospective registration was 0.1 mm +/- 1.5 mm and 0.2 degrees +/- 1.5 degrees. CONCLUSION: Image-based prospective registration using localizer images of the pre- and postexaminations is a robust method for reproducible slice positioning. Copyright 2004 Wiley-Liss, Inc.
PURPOSE: To facilitate assessing brain tumor growth and progression of stroke lesions by reproducible slice positioning in human head magnetic resonance (MR) images, a method for prospective registration is proposed that adjusts the image slice position without moving the patient and with no additional scans. MATERIALS AND METHODS: The gradient reference frame of follow-up examinations was adjusted to achieve the same image slice positioning relative to the patient as in the previous examination. The three-dimensional geometrical transformation parameters for the gradients were determined using two-dimensional image registration of three orthogonal localizer images. The method was developed and evaluated using a phantom with arbitrarily adjustable position. Feasibility for in vivo applications was demonstrated with brain MR imaging (MRI) of healthy volunteers. RESULTS: Standard retrospective registration was used for assessing the quality of the method. The accuracy of the realignment was 0.0 mm +/- 1.2 mm and -0.2 degrees +/- 0.9 degrees (mean +/- SD) in phantom experiments. In 10 examinations of volunteers, misalignments up to 49.2 mm and 21 degrees were corrected. The accuracy of the realignment after prospective registration was 0.1 mm +/- 1.5 mm and 0.2 degrees +/- 1.5 degrees. CONCLUSION: Image-based prospective registration using localizer images of the pre- and postexaminations is a robust method for reproducible slice positioning. Copyright 2004 Wiley-Liss, Inc.
Authors: Weiqiang Dou; Oliver Speck; Thomas Benner; Jörn Kaufmann; Meng Li; Kai Zhong; Martin Walter Journal: MAGMA Date: 2014-11-20 Impact factor: 2.310
Authors: Daniel Forsberg; Amit Gupta; Christopher Mills; Brett MacAdam; Beverly Rosipko; Barbara A Bangert; Michael D Coffey; Christos Kosmas; Jeffrey L Sunshine Journal: Int J Comput Assist Radiol Surg Date: 2016-11-26 Impact factor: 2.924
Authors: Bradley J Erickson; Julia Patriarche; Christopher Wood; Norbert Campeau; E Paul Lindell; Vladimir Savcenko; Norman Arslanlar; Liqin Wang Journal: Cancer Inform Date: 2007-05-12