Literature DB >> 15389502

Predicting in vivo failure of pseudoelastic NiTi devices under low cycle, high amplitude fatigue.

Jeremy M Young1, Krystyn J Van Vliet.   

Abstract

Due to the large reversible strains achievable through the stress-induced austenite-martensite phase transformation in NiTi alloys, NiTi has replaced stainless steel in the majority of large-strain biomedical applications such as root canal enlargement. However, the pseudoelasticity of NiTi is currently overshadowed by the short fatigue life of NiTi wires used in this low cycle (200-2000 rpm), high amplitude (epsilon(a) > 2.5%) application, resulting in in vivo fracture or premature retirement of otherwise reusable NiTi-based wire devices. In this study, the failure of pseudoelastic 55.8 wt % Ni-Ti wire is investigated experimentally, as a function of experimental parameters that include the clinically relevant regime. The effects of radius of curvature, angle of curvature, wire diameter, strain amplitude, cyclic frequency, volume under strain, and specific heat of the surrounding environmental fluid are considered systematically. These data indicate that the lifetime or cycles to failure N(f) of a rotating NiTi wire can be predicted via a modified Coffin-Manson relation that is a strong function of both strain amplitude and volume under strain, and a weaker function of frequency and fluid specific heat. The resulting quantitative relation can be used to predict useful device lifetime under clinically relevant conditions and thereby reduce incidences of in vivo failure. Copyright 2004 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15389502     DOI: 10.1002/jbm.b.30113

Source DB:  PubMed          Journal:  J Biomed Mater Res B Appl Biomater        ISSN: 1552-4973            Impact factor:   3.368


  4 in total

1.  Performance of NiTi endodontic instrument under different temperatures.

Authors:  Ahmed Jamleh; Yoshio Yahata; Arata Ebihara; Amre R Atmeh; Turki Bakhsh; Hideaki Suda
Journal:  Odontology       Date:  2015-08-22       Impact factor: 2.634

2.  Comparison and evaluation of surface deformation of Hyflex controlled memory and Hyflex electric discharge machining nickel titanium rotary files and cyclic fatigue resistance after instrumentation and heat sterilization - An in vitro study.

Authors:  Paramarshi Das; D V Swapna; Roopa R Nadig
Journal:  J Conserv Dent       Date:  2020-08-04

3.  Evaluation of dynamic and static torsional resistances of nickel-titanium rotary instruments.

Authors:  Ibrahim H Abu-Tahun; Jung-Hong Ha; Sang Won Kwak; Hyeon-Cheol Kim
Journal:  J Dent Sci       Date:  2018-02-01       Impact factor: 2.080

4.  Shape Loss of Autoclaved, Machine-Bent Cobalt-Chrome and Titanium Spine Surgery Rods.

Authors:  Rob Willson; Haitao Zhou; Sadanand Fulzele; Sean M Mitchell; Norman Chutkan
Journal:  Global Spine J       Date:  2020-03-19
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.