Literature DB >> 15383968

Functional imaging of parotid glands: diffusion-weighted echo-planar MRI before and after stimulation.

C R Habermann1, M C Cramer, J Graessner, P Gossrau, F Reitmeier, J Fiehler, V Schoder, M Jaehne, G Adam.   

Abstract

PURPOSE: To investigate the feasibility of diffusion-weighted (DW) echo-planar imaging (EPI) for measuring different functional conditions of the parotid gland and to compare different measurement approaches.
MATERIALS AND METHODS: Parotid glands of 27 healthy volunteers were examined with a DW EPI sequence (TR 1,500 msec, TE 77 msec, field-of-view 250 x 250 mm, pixel size 2.10 x 1.95 mm, section thickness 5 mm) before and after oral stimulation with commercially available lemon juice. The b factors used were 0, 500, and 1,000 sec/mm (2). Apparent diffusion coefficient (ADC) maps were digitally transferred to MRIcro (Chris Rorden, University of Nottingham, Great Britain) and evaluated with a manually placed circular region of interest (ROI) containing 100 - 200 pixel. Additional ROIs including the entire parotid gland were placed on either side. The results of both measurements were compared, using the Student's t test based on the median ADC values for each person. A two-tailed p-value of less than.05 was determined to indicate statistical significance. To compare both measurement approaches, the Pearson's correlation coefficient (r) was calculated.
RESULTS: Diffusion-weighted echo-planar MR imaging successfully visualized the parotid glands of all volunteers. In a first step, the median ADC value per person was computed. Using ROIs of 100 - 200 pixels, the mean was calculated to be 1.08 x 10 (- 3) mm (2)/sec +/- 0.12 x 10 (- 3) mm (2)/sec for both parotid glands prior to stimulation. After stimulation, the mean ADC was measured at 1.15 x 10 (- 3) mm (2)/sec +/- 0.11 x 10 (- 3) mm (2)/sec for both parotid glands. Evaluating the entire parotid gland, the ADC was 1.12 x 10 (- 3) mm (2)/sec +/- 0.08 x 10 (- 3) mm (2)/sec prior to stimulation, whereas the ADC increased to 1.18 x 10 (- 3) mm (2)/sec +/- 0.09 x 10 (- 3) mm (2)/sec after stimulation with lemon juice. For both types of measurements, the increase in ADC after stimulation proved to be significant (p < 0.001). High correlations between both measurement types were found (r >.83).
CONCLUSION: Diffusion-weighted echo-planar MR imaging allows non-invasive quantification of functional changes in the parotid glands.

Entities:  

Mesh:

Year:  2004        PMID: 15383968     DOI: 10.1055/s-2004-813564

Source DB:  PubMed          Journal:  Rofo        ISSN: 1438-9010


  5 in total

1.  Dynamic contrast-enhanced MR in the diagnosis of lympho-associated benign and malignant lesions in the parotid gland.

Authors:  Ling Zhu; Chunye Zhang; Yi Hua; Jie Yang; Qiang Yu; Xiaofeng Tao; Jiawei Zheng
Journal:  Dentomaxillofac Radiol       Date:  2016-02-05       Impact factor: 2.419

Review 2.  Extracranial applications of diffusion-weighted magnetic resonance imaging.

Authors:  Harriet C Thoeny; Frederik De Keyzer
Journal:  Eur Radiol       Date:  2007-01-06       Impact factor: 5.315

3.  Value of apparent diffusion coefficient calculation before and after gustatory stimulation in the diagnosis of acute or chronic parotitis.

Authors:  T Ries; C Arndt; M Regier; J Graessner; M C Cramer; F Reitmeier; M Jaehne; G Adam; C R Habermann
Journal:  Eur Radiol       Date:  2008-05-06       Impact factor: 5.315

4.  Monitoring of gustatory stimulation of salivary glands by diffusion-weighted MR imaging: comparison of 1.5T and 3T.

Authors:  C R Habermann; P Gossrau; H Kooijman; J Graessner; M C Cramer; M G Kaul; F Reitmeier; M Jaehne; G Adam
Journal:  AJNR Am J Neuroradiol       Date:  2007-09       Impact factor: 3.825

5.  Evaluating Instantaneous Perfusion Responses of Parotid Glands to Gustatory Stimulation Using High-Temporal-Resolution Echo-Planar Diffusion-Weighted Imaging.

Authors:  T-W Chiu; Y-J Liu; H-C Chang; Y-H Lee; J-C Lee; K Hsu; C-W Wang; J-M Yang; H-H Hsu; C-J Juan
Journal:  AJNR Am J Neuroradiol       Date:  2016-06-23       Impact factor: 3.825

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.