Literature DB >> 1537909

Cross-infection risks associated with current procedures for using high-speed dental handpieces.

D L Lewis1, R K Boe.   

Abstract

When a dye solution used to simulate patient material was either injected into high-speed dental handpiece (drill) waterlines or applied to the equipment externally, internal air turbine chambers became contaminated. These chambers served as a reservoir of the material, which was slowly dislodged by air expelled during subsequent handpiece operation and which was diluted by water spray used for cooling the drilling surface. Considering the fact that patient materials could reside in internal parts of the equipment that are not usually disinfected and that the material may be subsequently sprayed into cuts and abrasions in the oral cavity, the common approach to reprocessing handpieces (external wiping in combination with flushing) may pose unacceptably high risks to those individuals treated soon after infected patients. Therefore, unless reliable data on cross-infection frequencies are obtained and prove it unnecessary, heat-treating high-speed handpieces between each patient should be considered an essential component of standard procedures whenever universal precautions are practiced in dentistry.

Entities:  

Mesh:

Year:  1992        PMID: 1537909      PMCID: PMC265068          DOI: 10.1128/jcm.30.2.401-406.1992

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  19 in total

1.  Management considerations for an HIV positive dental student.

Authors:  R W Comer; D R Myers; C D Steadman; M J Carter; J P Rissing; F J Tedesco
Journal:  J Dent Educ       Date:  1991-03       Impact factor: 2.264

2.  The dentist and infectious diseases: a national survey of attitudes and behavior.

Authors:  A C Verrusio; E A Neidle; K D Nash; S Silverman; A M Horowitz; K S Wagner
Journal:  J Am Dent Assoc       Date:  1989-05       Impact factor: 3.634

Review 3.  State-of-the-art infection control in dentistry.

Authors:  J A Cottone; J A Molinari
Journal:  J Am Dent Assoc       Date:  1991-08       Impact factor: 3.634

4.  Evaluation of a dental unit designed to prevent retraction of oral fluids.

Authors:  J J Crawford; C Broderius
Journal:  Quintessence Int       Date:  1990-01       Impact factor: 1.677

5.  Control of cross-contamination.

Authors:  N Neugeboren; R J Nisengard; E H Beutner; G W Ferguson
Journal:  J Am Dent Assoc       Date:  1972-07       Impact factor: 3.634

6.  Hepatitis B transmission by dentists.

Authors:  M L Levin; W C Maddrey; J R Wands; A L Mendeloff
Journal:  JAMA       Date:  1974-05-27       Impact factor: 56.272

7.  Transmission of HBV from dental personnel to patients.

Authors:  M A Kane; L A Lettau
Journal:  J Am Dent Assoc       Date:  1985-04       Impact factor: 3.634

8.  Control of cross-infection risks in the dental operatory: prevention of water retraction by bur cooling spray systems.

Authors:  J J Crawford; C Broderius
Journal:  J Am Dent Assoc       Date:  1988-05       Impact factor: 3.634

9.  Studies on dental aerobiology. IV. Bacterial contamination of water delivered by dental units.

Authors:  L C Abel; R L Miller; R E Micik; G Ryge
Journal:  J Dent Res       Date:  1971 Nov-Dec       Impact factor: 6.116

10.  Hepatitis in dental professionals.

Authors:  R E Feldman; E R Schiff
Journal:  JAMA       Date:  1975-06-23       Impact factor: 56.272

View more
  4 in total

1.  Development of a validated process for manual preparation of dental transmission instruments.

Authors:  Andre Büchter; Birgit Kruse-Loesler
Journal:  Clin Oral Investig       Date:  2010-05-19       Impact factor: 3.573

2.  Cross-infection risks associated with high-speed dental drills.

Authors:  S D Carter
Journal:  J Clin Microbiol       Date:  1992-07       Impact factor: 5.948

3.  Breaking the Chain of Infection: Dental Unit Water Quality Control.

Authors:  Amrita Pawar; Sandeep Garg; Sonia Mehta; Rajat Dang
Journal:  J Clin Diagn Res       Date:  2016-07-01

4.  Pilot study: Internally cooled orthopedic drills - standard sterilization is not enough?

Authors:  Tomislav Bruketa; Goran Augustin; Selma Pintarić; Branka Šeol-Martinec; Ivan Dobrić; Bore Bakota
Journal:  Acta Clin Croat       Date:  2019-06       Impact factor: 0.780

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.