A 12 month clinical study of bond failures of recycled versus new stainless steel orthodontic brackets.

Vittorio Cacciafesta1, Maria Francesca Sfondrini, Birte Melsen, Andrea Scribante.   

Abstract

The purpose of this prospective longitudinal randomized study was to compare the clinical performance of recycled brackets with that of new stainless steel brackets (Orthos). Twenty patients treated with fixed appliances were included in the investigation. Using a 'split-mouth' design, the dentition of each patient was divided into four quadrants. In 11 randomly selected patients, the maxillary left and mandibular right quadrants were bonded with recycled brackets, and the remaining quadrants with new stainless steel brackets. In the other nine patients the quadrants were inverted. Three hundred and ten stainless steel brackets were examined: 156 were recycled and the remaining 154 were new. All the brackets were bonded with a self-cured resin-modified glass ionomer (GC Fuji Ortho). The number, cause, and date of bracket failures were recorded over 12 months. Statistical analysis was performed by means of a paired t-test, Kaplan-Meier survival estimates, and the log-rank test. No statistically significant differences were found between: (a) the total bond failure rate of recycled and new stainless steel brackets; (b) the upper and lower arches; (c) the anterior and posterior segments. These findings demonstrate that recycling metallic orthodontic brackets can be of benefit to the profession, both economically and ecologically, as long as the orthodontist is aware of the various aspects of the recycling methods, and that patients are informed about the type of bracket that will be used for their treatment.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15366391     DOI: 10.1093/ejo/26.4.449

Source DB:  PubMed          Journal:  Eur J Orthod        ISSN: 0141-5387            Impact factor:   3.075


  10 in total

1.  Repeated bonding of fixed retainer increases the risk of enamel fracture.

Authors:  Netrporn Chinvipas; Yuh Hasegawa; Kazuto Terada
Journal:  Odontology       Date:  2012-12-14       Impact factor: 2.634

2.  Reconditioning of self-ligating brackets.

Authors:  Maria Francesca Sfondrini; Esmeralda Xheka; Andrea Scribante; Paola Gandini; Giuseppe Sfondrini
Journal:  Angle Orthod       Date:  2011-08-01       Impact factor: 2.079

3.  Clinical effect of reducing curing times with high-intensity LED lights.

Authors:  Justin D Ward; Bethany J Wolf; Luis P Leite; Jing Zhou
Journal:  Angle Orthod       Date:  2015-03-11       Impact factor: 2.079

4.  Comparison of shear bond strength of brackets recycled using micro sandblasting and industrial methods.

Authors:  Manuela M Haro Montero; Ascensión Vicente; Noelia Alfonso-Hernández; Manuel Jiménez-López; Luis-Alberto Bravo-González
Journal:  Angle Orthod       Date:  2014-09-17       Impact factor: 2.079

5.  Effect of multiple debonding sequences on shear bond strength of new stainless steel brackets.

Authors:  Ladan Eslamian; Ali Borzabadi-Farahani; Pegah Tavakol; Ali Tavakol; Nazila Amini; Edward Lynch
Journal:  J Orthod Sci       Date:  2015 Apr-Jun

6.  Evaluation of the effect of three innovative recyling methods on the shear bond strength of stainless steel brackets-an in vitro study.

Authors:  Neeraj Gupta; Dilip Kumar; Aparna Palla
Journal:  J Clin Exp Dent       Date:  2017-04-01

7.  Reliability of Orthodontic Miniscrews: Bending and Maximum Load of Different Ti-6Al-4V Titanium and Stainless Steel Temporary Anchorage Devices (TADs).

Authors:  Andrea Scribante; Mona A Montasser; Eman Saad Radwan; Luisa Bernardinelli; Roberto Alcozer; Paola Gandini; Maria Francesca Sfondrini
Journal:  Materials (Basel)       Date:  2018-07-05       Impact factor: 3.623

8.  Evaluation of Bond Failure Rate of Orthodontic Brackets Bonded with Green Gloo-Two Way Color Changes Adhesive: A Clinical Study.

Authors:  Zuber Ahamed Naqvi; Saleem Shaikh; Zameer Pasha
Journal:  Ethiop J Health Sci       Date:  2019-03

9.  Comparison of Streptococcus mutans Adhesion on New and Recycled Metal Brackets: An In Vitro Study.

Authors:  Vasumathi Thiruvengadam; Arun B Chitharanjan; Kennedy Kumar; Venkatesan Singaram
Journal:  Cureus       Date:  2022-03-28

Review 10.  Incidence of orthodontic brackets detachment during orthodontic treatment: A systematic review.

Authors:  Naif Almosa; Hamayun Zafar
Journal:  Pak J Med Sci       Date:  2018 May-Jun       Impact factor: 1.088