Literature DB >> 15365925

Relationship between peripheral and central venous pressures in different patient positions, catheter sizes, and insertion sites.

Mehmet Tugrul1, Emre Camci, Kamil Pembeci, Ayman Al-Darsani, Lütfi Telci.   

Abstract

OBJECTIVE: To investigate the relationship between peripheral and central venous pressures in different patient positions (supine, prone, lithotomy, Trendelenburg, and Fowler), different catheter diameters (18 G and 20 G), and catheterization sites (dorsal hand and forearm) during surgical procedures.
DESIGN: Prospective clinical study. SETTINGS: University hospital. PARTICIPANTS: Five hundred adult patients.
INTERVENTIONS: Peripheral over-the-needle intravenous catheters were placed in the dorsal hand or forearm. Central venous catheters were inserted via the internal jugular or subclavian vein after induction of anesthesia.
MEASUREMENTS AND MAIN RESULTS: Simultaneous measurements of central and peripheral venous pressures were made during stable conditions at random time points in surgery; 1953 paired measurements were performed. Mean central venous pressure was 11 +/- 3.7 mmHg and peripheral venous pressure was 13 +/- 4 mmHg (p = 0.0001). The overall correlation between central venous and peripheral venous pressures was found to be statistically significant (r = 0.89, r(2) = 0.8, p = 0.0001). Mean difference between peripheral and central venous pressure was 2 +/- 1.8 mmHg. Ninety-five percent limits of agreement were 5.6 to -1.6 mmHg.
CONCLUSION: It has been assumed that replacing central venous pressure by peripheral venous pressure would cause problems in clinical interpretation. If the validity of this data is confirmed by further studies, the authors suggest that central venous pressure could be estimated by using regression equations to compare the 2 methods.

Entities:  

Mesh:

Year:  2004        PMID: 15365925     DOI: 10.1053/j.jvca.2004.05.022

Source DB:  PubMed          Journal:  J Cardiothorac Vasc Anesth        ISSN: 1053-0770            Impact factor:   2.628


  9 in total

1.  Ocular changes over 60 min in supine and prone postures.

Authors:  Allison P Anderson; Gautam Babu; Jacob G Swan; Scott D Phillips; Darin A Knaus; Christine M Toutain-Kidd; Michael E Zegans; Abigail M Fellows; Jiang Gui; Jay C Buckey
Journal:  J Appl Physiol (1985)       Date:  2017-05-25

2.  Influence of tissue pressure on central venous pressure/peripheral venous pressure correlation: An experimental report.

Authors:  Martyn G Harvey; Grant Cave
Journal:  World J Emerg Med       Date:  2011

3.  Comparative utility of centrally versus peripherally transduced venous pressure monitoring in the perioperative period in spine surgery patients.

Authors:  Anna Maria Bombardieri; James Beckman; Pamela Shaw; Federico P Girardi; Yan Ma; Stavros G Memtsoudis
Journal:  J Clin Anesth       Date:  2012-09-20       Impact factor: 9.452

4.  Continuous measurement of cardiac output with the electrical velocimetry method in patients under spinal anesthesia for cesarean delivery.

Authors:  Yanhong Liu; May C M Pian-Smith; Lisa R Leffert; Rebecca D Minehart; Andrea Torri; Charles Coté; Robert M Kacmarek; Yandong Jiang
Journal:  J Clin Monit Comput       Date:  2014-12-16       Impact factor: 2.502

5.  Forehead reflectance oximetry: a clinical comparison with conventional digit sensors during laparotomic and laparoscopic abdominal surgery.

Authors:  Andrea Casati; Grazia Squicciarini; Marco Baciarello; Marta Putzu; Alessandra Salvadori; Guido Fanelli
Journal:  J Clin Monit Comput       Date:  2007-08-16       Impact factor: 2.502

6.  A Novel Non-Invasive Device for the Assessment of Central Venous Pressure in Hospital, Office and Home.

Authors:  Emanuela Marcelli; Laura Cercenelli; Barbara Bortolani; Saverio Marini; Luca Arfilli; Alessandro Capucci; Gianni Plicchi
Journal:  Med Devices (Auckl)       Date:  2021-05-13

7.  Peripheral venous pressure as a reliable predictor for monitoring central venous pressure in patients with burns.

Authors:  Lulu Sherif; Vikas S Joshi; Anjali Ollapally; Prithi Jain; Kishan Shetty; Karl Sa Ribeiro
Journal:  Indian J Crit Care Med       Date:  2015-04

8.  Peripheral venous pressure as a reliable predictor for monitoring central venous pressure in patients with burns.

Authors:  Shakti Bedanta Mishra; Afzal Azim
Journal:  Indian J Crit Care Med       Date:  2015-07

9.  Correlation between central venous pressure and peripheral venous pressure with passive leg raise in patients on mechanical ventilation.

Authors:  Dharmendra Kumar; Syed Moied Ahmed; Shahna Ali; Utpal Ray; Ankur Varshney; Kashmiri Doley
Journal:  Indian J Crit Care Med       Date:  2015-11
  9 in total