Literature DB >> 15354078

Outflow resistance of the Baerveldt glaucoma drainage implant and modifications for early postoperative intraocular pressure control.

R Reid Breckenridge1, Luanna R Bartholomew, Craig E Crosson, Alexander R Kent.   

Abstract

PURPOSE: To determine outflow resistance of the Baerveldt glaucoma implant using different tube configurations.
METHODS: Outflow resistance of 6 tube configurations (C1- C6) of Baerveldt implants was measured under conditions of constant pressure perfusion. Pressures ranged from 2 to 55 mm Hg. Venting slits were created using a 7-0 Vicryl, spatulated suture-needle. Seton tubes were occluded by threading a retrograde suture approximately 1.5 cm into the lumen.
RESULTS: At pressures between 2 and 55 mm Hg, mean outflow resistance of the normally configured seton (ie, open tube; C1) was 0.41 (+/- 0.6) mm Hg/microL/min. Resistance was unchanged (mean 0.41 (+/- 0.4) mm Hg/microL/min) by the addition of 4 venting slits (C2) to the seton tube. Occlusion of the open seton tube with a 3-0 Supramid suture (C3) significantly increased (P < 0.001) mean outflow resistance to 14.99 (+/- 0.6) mm Hg/microL/min. Occlusion of the tube with a 4-0 Supramid suture (C4) significantly increased (P < 0.001) mean outflow resistance to 1.09 (+/- 0.5) mm Hg/microL/min. In implants where tubes were occluded with a 3-0 Supramid suture, the addition of venting slits (C5) significantly decreased (P = 0.038) mean outflow resistance to 8.98 (+/- 0.4) mm Hg/microL/min. In tubes occluded with a 4-0 Supramid suture, the addition of venting slits (C6) decreased mean outflow resistance to 0.98 (+/- 0.6) mm Hg/microL/min.
CONCLUSIONS: Although these results cannot be directly correlated to the clinical setting, they do show that outflow resistance can be modified at the time of surgery by changing tube configuration of the Baerveldt glaucoma implant. Configuration C5 (3-0 Supramid with venting slits) closely approximates the outflow rate in the normal intraocular pressure range.

Entities:  

Mesh:

Year:  2004        PMID: 15354078     DOI: 10.1097/01.ijg.0000131759.48295.5c

Source DB:  PubMed          Journal:  J Glaucoma        ISSN: 1057-0829            Impact factor:   2.503


  4 in total

Review 1.  [Revision surgery in episcleral glaucoma drainage devices].

Authors:  A Rosentreter; T S Dietlein
Journal:  Ophthalmologe       Date:  2016-11       Impact factor: 1.059

Review 2.  Modern concepts in antiglaucomatous implant surgery.

Authors:  T S Dietlein; J Jordan; C Lueke; G K Krieglstein
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2008-08-06       Impact factor: 3.117

3.  Comparison of Two Tube-Modification Techniques in Baerveldt Glaucoma Implantation in Refractory Glaucoma.

Authors:  Purit Petpiroon; Thanyathorn Vijittrakarnrung; Wasu Supakontanasan; Apichat Tantraworasin; Yanin Suwan
Journal:  Clin Ophthalmol       Date:  2020-06-19

4.  One-year Outcomes Following Internal Ligation Suture Removal in 350 mm2 Baerveldt Tube Implant Surgery.

Authors:  Francesco Stringa; Ruth Chen; Pavi Agrawal
Journal:  J Curr Glaucoma Pract       Date:  2022 Jan-Apr
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.