Temperature threshold for burn injury: an oximeter safety study.

David G Greenhalgh1, Mary Beth Lawless, Bradford B Chew, Willem A Crone, Michael E Fein, Tina L Palmieri.   

Abstract

Pulse oximeters have become essential devices for evaluating and monitoring patient oxygenation. The probe emits a small amount of heat into the skin in the process of signal detection. Regulations set by the Food and Drug Administration currently limit the maximum allowable temperature of an oximeter probe to 41 degrees C. As a result of the prolonged exposure of extremities to these devices, we sought to determine the actual temperature threshold for burn injury in patients. Eighteen patients undergoing surgery for removal of redundant skin (abdominoplasty, breast reduction) consented to the application of a temperature-controlled custom probe with four light-emitting diodes that had temperatures set randomly at the expected threshold for burn injury (42.5 degrees C, 43 degrees C, 43.5 degrees C, and 44 degrees C). The probe was left in place for 8 hours (or less if significant pain was noted). The sites covered by the probes were then checked for signs of injury. On the next day, the redundant skin was removed as a scheduled procedure, and histopathology was performed to detect the extent of burn injury. The study was approved by the local institutional research board. Two patients were excluded because of technical problems with the probe, one of whom had the probe turned off because of pain. The only observed sign of injury was either erythema or a superficial blister that was usually unobservable or slightly red at operation. These subtle signs of a burn were noted in one patient at 43 degrees C, four at 43.5 degrees C, and nine at 44 degrees C. No burns were noted in two patients. Minimal or no signs of injury frequently were noted by histopathology. Pulse oximeter probes are safe up to a temperature of 43 degrees C for at least 8 hours in well-perfused skin. Above that temperature, there is a risk of burn injury. Performing temperature threshold tests in redundant skin that is planned for excision is a potential method for testing the safety of devices or materials.

Entities:  

Mesh:

Year:  2004        PMID: 15353932     DOI: 10.1097/01.bcr.0000138295.63830.90

Source DB:  PubMed          Journal:  J Burn Care Rehabil        ISSN: 0273-8481


  6 in total

1.  Faster in and faster out: accelerating insulin absorption and action by insulin infusion site warming.

Authors:  Eda Cengiz; Stuart A Weinzimer; Jennifer L Sherr; Eileen M Tichy; Lori Carria; Darryll Cappiello; Amy Steffen; William V Tamborlane
Journal:  Diabetes Technol Ther       Date:  2013-12-24       Impact factor: 6.118

Review 2.  Thresholds for thermal damage to normal tissues: an update.

Authors:  Pavel S Yarmolenko; Eui Jung Moon; Chelsea Landon; Ashley Manzoor; Daryl W Hochman; Benjamin L Viglianti; Mark W Dewhirst
Journal:  Int J Hyperthermia       Date:  2011       Impact factor: 3.914

3.  Systemic and Local Effects of Warm Oxygen Exposure to the Lower Extremities in Healthy Volunteers.

Authors:  Vidya Sunil Joshi; Sunil Subhash Joshi
Journal:  J Clin Diagn Res       Date:  2017-04-01

4.  CEM43°C thermal dose thresholds: a potential guide for magnetic resonance radiofrequency exposure levels?

Authors:  Gerard C van Rhoon; Theodoros Samaras; Pavel S Yarmolenko; Mark W Dewhirst; Esra Neufeld; Niels Kuster
Journal:  Eur Radiol       Date:  2013-04-04       Impact factor: 5.315

5.  Thermal burns on lower limb resulting from laptop use: A case report and review of literature.

Authors:  Nebu C Jacob; Adel Zarugh; Khushroo H Suraliwala
Journal:  Indian J Plast Surg       Date:  2014 Sep-Dec

6.  Wearable and modular functional near-infrared spectroscopy instrument with multidistance measurements at four wavelengths.

Authors:  Dominik Wyser; Olivier Lambercy; Felix Scholkmann; Martin Wolf; Roger Gassert
Journal:  Neurophotonics       Date:  2017-08-18       Impact factor: 3.593

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.