Literature DB >> 15349733

[Oncologic screening with whole-body MRI: possibilities and limitations].

J F Schäfer1, A Fischmann, M Lichy, J Vollmar, M Fenchel, C D Claussen, H-P Schlemmer.   

Abstract

In the last decade the interest in radiological screening examination increased among informed laymen enormously. Independent from the evidence of whole-body examinations for cancer prevention the discussion about screening must again be considered again due to the newest technical developments, since MRI of the whole-body with high spatial resolution is feasible now within one single examination. The newest system permits simultaneous connection of up to 76 coil elements and signal reception from 32 independent receiving channels. Whole-body MRI including magnetic resonance colonography (MRC) is feasible within 60 min. In this review potential investigation protocols will be presented. Potentials, challenges and limitations of whole-body MRI in the prevention of the malignancies most frequently leading to death are discussed on the basis own experiences examples and the literature.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15349733     DOI: 10.1007/s00117-004-1104-y

Source DB:  PubMed          Journal:  Radiologe        ISSN: 0033-832X            Impact factor:   0.635


  49 in total

1.  [Whole-body MRA on a rolling table platform (AngioSURF)].

Authors:  S G Ruehm; M Goyen; H H Quick; M Schlepütz; H Schlepütz; S Bosk; J Barkhausen; M E Ladd; J F Debatin
Journal:  Rofo       Date:  2000-08

Review 2.  Screening with MRI: a new "all inclusive" protocol.

Authors:  Susanne C Goehde; Michael Forsting; Jörg F Debatin
Journal:  Semin Ultrasound CT MR       Date:  2003-02       Impact factor: 1.875

3.  [Early lung cancer detection with low-dose CT: an update].

Authors:  S Diederich; D Wormanns; W Heindel
Journal:  Radiologe       Date:  2002-08       Impact factor: 0.635

4.  Screening for early lung cancer with low-dose spiral CT: prevalence in 817 asymptomatic smokers.

Authors:  Stefan Diederich; Dag Wormanns; Michael Semik; Michael Thomas; Horst Lenzen; Nikolaus Roos; Walter Heindel
Journal:  Radiology       Date:  2002-03       Impact factor: 11.105

5.  Dark lumen MR-colonography: initial experience.

Authors:  T C Lauenstein; C U Herborn; F M Vogt; S C Göhde; J F Debatin; S G Ruehm
Journal:  Rofo       Date:  2001-09

6.  Turbo STIR magnetic resonance imaging as a whole-body screening tool for metastases in patients with breast carcinoma: preliminary clinical experience.

Authors:  R Walker; P Kessar; R Blanchard; M Dimasi; K Harper; V DeCarvalho; E K Yucel; L Patriquin; S Eustace
Journal:  J Magn Reson Imaging       Date:  2000-04       Impact factor: 4.813

7.  Lung cancer screening with CT: Mayo Clinic experience.

Authors:  Stephen J Swensen; James R Jett; Thomas E Hartman; David E Midthun; Jeff A Sloan; Anne-Marie Sykes; Gregory L Aughenbaugh; Medy A Clemens
Journal:  Radiology       Date:  2003-01-24       Impact factor: 11.105

8.  Whole-body MRI using a rolling table platform for the detection of bone metastases.

Authors:  Thomas C Lauenstein; Lutz S Freudenberg; Susanne C Goehde; Stefan G Ruehm; Mathias Goyen; Silke Bosk; Jörg F Debatin; Jörg Barkhausen
Journal:  Eur Radiol       Date:  2002-03-08       Impact factor: 5.315

Review 9.  Colon polyps and cancer.

Authors:  J H Bond
Journal:  Endoscopy       Date:  2003-01       Impact factor: 10.093

10.  Lung morphology: fast MR imaging assessment with a volumetric interpolated breath-hold technique: initial experience with patients.

Authors:  Jürgen Biederer; Marcus Both; Joachim Graessner; Carsten Liess; Peter Jakob; Michael Reuter; Martin Heller
Journal:  Radiology       Date:  2003-01       Impact factor: 11.105

View more
  3 in total

1.  [Cost considerations for whole-body MRI and PET/CT as part of oncologic staging].

Authors:  C Plathow; M Walz; M P Lichy; P Aschoff; C Pfannenberg; H Bock; S M Eschmann; C D Claussen; H P Schlemmer
Journal:  Radiologe       Date:  2008-04       Impact factor: 0.635

2.  MRI of respiratory dynamics with 2D steady-state free-precession and 2D gradient echo sequences at 1.5 and 3 Tesla: an observer preference study.

Authors:  M Fabel; B J Wintersperger; O Dietrich; M Eichinger; C Fink; M Puderbach; H-U Kauczor; S O Schoenberg; J Biederer
Journal:  Eur Radiol       Date:  2008-09-06       Impact factor: 5.315

3.  [Imaging of abdominal tumors in childhood and adolescence : Part II: relevant intra-abdominal and retroperitoneal tumor entities].

Authors:  D M Renz; H-J Mentzel
Journal:  Radiologe       Date:  2018-07       Impact factor: 0.635

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.