Literature DB >> 15348305

X-ray diffraction characterization of dental gold alloy-ceramic interfaces.

Z Cai1, I Watanabe, J C Mitchell, W A Brantley, T Okabe.   

Abstract

X-ray diffraction (XRD) was employed to study dental alloy-ceramic interfaces. A Au-Pd-In alloy, which requires oxidation before porcelain firing, and a Au-Pt-Pd-In alloy, which does not require oxidation before porcelain firing, were selected in this study. Alloy specimens were centrifugally cast. Specimen surfaces were metallographically polished through 0.05 microm Al2O3 slurries. A thin layer (< 50 microm) of a dental opaque porcelain was fired on the alloy surfaces with and without initial oxidation. XRD was conducted at room temperature on four types of alloy specimens: polished, oxidized, porcelain fired after alloy oxidation, and porcelain fired without initial alloy oxidation. XRD was also performed on fired opaque porcelain without an alloy substrate. The detection of prominent gold solid solution peaks from alloy-ceramic specimens indicated that the incident X-ray beam reached the alloy-ceramic interface. In2O3 and beta-Ga2O3 were identified on the oxidized Au-Pd-In alloy, while In2O3 and SnO2 were detected on the oxidized Au-Pt-Pd-In alloy. Preferred orientation was observed for all the oxides formed on the alloys. Minimum lattice parameter changes (<1%) for the gold solid solutions were observed for both alloys before and after oxidation and porcelain firing. Leucite (KAlSi2O6, TiO2, ZrO2 and SnO2 were detected on the fired opaque porcelain. For both alloys, no additional oxides were identified at the metal-ceramic interfaces beyond those present in the oxidized alloys and the opaque porcelain. Similar results were obtained from alloy-ceramic interfaces where there was no prior alloy oxidation. The results indicate the critical role of alloy surface oxides in metal-ceramic bonding and support the chemical bonding mechanism for porcelain adherence. Copyright 2001 Kluwer Academic Publishers

Entities:  

Year:  2001        PMID: 15348305     DOI: 10.1023/a:1008906930748

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  28 in total

1.  The effect of oxidation heat treatment of porcelain bond strength in selected base metal alloys.

Authors:  Y Wu; J B Moser; L M Jameson; W F Malone
Journal:  J Prosthet Dent       Date:  1991-10       Impact factor: 3.426

Review 2.  Designs of bond strength tests for metal-ceramic complexes: review of the literature.

Authors:  I A Hammad; Y F Talic
Journal:  J Prosthet Dent       Date:  1996-06       Impact factor: 3.426

3.  A comparative strength study of metal ceramic and all-ceramic esthetic materials: modulus of rupture.

Authors:  S D Campbell
Journal:  J Prosthet Dent       Date:  1989-10       Impact factor: 3.426

4.  X-ray diffraction studies of oxidized high-palladium alloys.

Authors:  W A Brantley; Z Cai; E Papazoglou; J C Mitchell; S J Kerber; G P Mann; T L Barr
Journal:  Dent Mater       Date:  1996-11       Impact factor: 5.304

5.  A rapid heating and cooling rate dilatometer for measuring thermal expansion in dental porcelain.

Authors:  S W Twiggs; J R Searle; R D Ringle; C W Fairhurst
Journal:  J Dent Res       Date:  1989-09       Impact factor: 6.116

6.  Effect of varying surface texture on bond strength of one semiprecious and one nonprecious ceramo-alloy.

Authors:  M A Carpenter; R J Goodkind
Journal:  J Prosthet Dent       Date:  1979-07       Impact factor: 3.426

7.  [Experimental study on the nature of the ceramic-metallic bonding].

Authors:  J N Nally; J M Meyer
Journal:  SSO Schweiz Monatsschr Zahnheilkd       Date:  1970

Review 8.  Coatings of ceramics on metals.

Authors:  D W Jones
Journal:  Ann N Y Acad Sci       Date:  1988       Impact factor: 5.691

9.  A clinical evaluation of two base metal alloys and a gold alloy for use in fixed prosthodontics: a five-year study.

Authors:  J P Moffa; W A Jenkins; J A Ellison; J C Hamilton
Journal:  J Prosthet Dent       Date:  1984-10       Impact factor: 3.426

10.  An x-ray spectrometric technique for measuring porcelain-metal adherence.

Authors:  R D Ringle; J R Mackert; C W Fairhurst
Journal:  J Dent Res       Date:  1983-08       Impact factor: 6.116

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.