Literature DB >> 15348087

Bone fracture analysis on the short rod chevron-notch specimens using the X-ray computer micro-tomography.

R De Santis1, P Anderson, K E Tanner, L Ambrosio, L Nicolais, W Bonfield, G R Davis.   

Abstract

Mechanical fatigue of bone leads to micro-cracking which is associated with remodeling, establishing a balance in the microcrack population of the living tissue, thus, in the steady-state, the microstructure of bone provides sites of discontinuity acting as stress raisers. Hence fracture toughness plays a decisive role in bone functionality by determining the level to which the material can be stressed in the presence of cracks, or, equivalently, the magnitude of cracking which can be tolerated at a given stress level. Cortical bone, which behaves as a quasi-brittle solid when fractured, was tested as short-rod chevron-notched tension specimens (CNT). The main features of the CNT specimen are its geometry and the V shaped notch. The notch leads to steady-state crack propagation whilst the requested geometry allows a diameter 40% smaller than the thickness of a standard compact tension specimens (CT). These features are essential to distinguish the inhomogeneties in the fracture properties of materials like bone. Bone structure and crack propagation of the CNT specimens were analyzed using X-ray computed micro-tomography (XMT), which is a non-invasive imaging technique. The unique feature of the micro-CT is the high resolution three-dimensional image which consists of multi-sliced tomographs taken in a fine pitch along the rotational axis. Fracture toughness (K(IC)) computed according to the peak load was 4.8 MNm(-3/2) while that derived from experimental calibration tests using XMT was 4.9 MNm(-3/2). Copyright 2000 Kluwer Academic Publishers

Entities:  

Year:  2000        PMID: 15348087     DOI: 10.1023/a:1008909830421

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  26 in total

1.  Description of a prototype emission-transmission computed tomography imaging system.

Authors:  T F Lang; B H Hasegawa; S C Liew; J K Brown; S C Blankespoor; S M Reilly; E L Gingold; C E Cann
Journal:  J Nucl Med       Date:  1992-10       Impact factor: 10.057

2.  Fracture toughness of compact bone.

Authors:  W Bonfield; P K Datta
Journal:  J Biomech       Date:  1976       Impact factor: 2.712

3.  Three-Dimensional X-ray Microtomography.

Authors:  B P Flannery; H W Deckman; W G Roberge; K L D'Amico
Journal:  Science       Date:  1987-09-18       Impact factor: 47.728

4.  Age-related differences in post-yield damage in human cortical bone. Experiment and model.

Authors:  A C Courtney; W C Hayes; L J Gibson
Journal:  J Biomech       Date:  1996-11       Impact factor: 2.712

Review 5.  X-ray microtomography of bones and teeth.

Authors:  G R Davis; F S Wong
Journal:  Physiol Meas       Date:  1996-08       Impact factor: 2.833

6.  Orientation dependence of the fracture mechanics of cortical bone.

Authors:  J C Behiri; W Bonfield
Journal:  J Biomech       Date:  1989       Impact factor: 2.712

7.  Resistance to crack growth in human cortical bone is greater in shear than in tension.

Authors:  T L Norman; S V Nivargikar; D B Burr
Journal:  J Biomech       Date:  1996-08       Impact factor: 2.712

Review 8.  Fracture mechanics of bone.

Authors:  J W Melvin
Journal:  J Biomech Eng       Date:  1993-11       Impact factor: 2.097

9.  Fracture mechanics of bone--the effects of density, specimen thickness and crack velocity on longitudinal fracture.

Authors:  J C Behiri; W Bonfield
Journal:  J Biomech       Date:  1984       Impact factor: 2.712

10.  Fracture toughness of human bone under tension.

Authors:  T L Norman; D Vashishth; D B Burr
Journal:  J Biomech       Date:  1995-03       Impact factor: 2.712

View more
  3 in total

1.  Mechanical and leakage behaviour of the dentin--adhesive interface.

Authors:  Francesco Mollica; Roberto De Santis; Luigi Ambrosio; Luigi Nicolais; Davide Prisco; Sandro Rengo
Journal:  J Mater Sci Mater Med       Date:  2004-04       Impact factor: 3.896

2.  Dynamic mechanical behavior of PMMA based bone cements in wet environment.

Authors:  R De Santis; F Mollica; L Ambrosio; L Nicolais; D Ronca
Journal:  J Mater Sci Mater Med       Date:  2003-07       Impact factor: 3.896

Review 3.  Finite element method (FEM), mechanobiology and biomimetic scaffolds in bone tissue engineering.

Authors:  A Boccaccio; A Ballini; C Pappalettere; D Tullo; S Cantore; A Desiate
Journal:  Int J Biol Sci       Date:  2011-01-26       Impact factor: 6.580

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.