Literature DB >> 15342071

Contact between 3 phakic intraocular lens models and the crystalline lens: an anterior chamber optical coherence tomography study.

Georges Baikoff1, Eric Lutun, Jay Wei, Caroline Ferraz.   

Abstract

Three phakic intraocular lens (IOL) models were implanted in 3 different patients. With the usual slitlamp examination, it was not possible to determine whether there was contact between the IOLs and the natural crystalline lens. Using the anterior chamber optical coherence tomography (AC OCT) scanner, direct contact between the natural crystalline lens and the 3 phakic IOLs was revealed. A dynamic study of the contact was performed during accommodation. These observations show that examination of the anterior segment with the AC OCT scanner provides new data about the status of the anterior segment after implantation of phakic IOLs.

Entities:  

Mesh:

Year:  2004        PMID: 15342071     DOI: 10.1016/j.jcrs.2004.05.018

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  10 in total

1.  Three-year follow-up of subjective vault following myopic implantable collamer lens implantation.

Authors:  José F Alfonso; Carlos Lisa; A Abdelhamid; Paulo Fernandes; Jorge Jorge; Robert Montés-Micó
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-03-24       Impact factor: 3.117

Review 2.  Recent advances in ophthalmic anterior segment imaging: a new era for ophthalmic diagnosis?

Authors:  Aristides Konstantopoulos; Parwez Hossain; David F Anderson
Journal:  Br J Ophthalmol       Date:  2007-04       Impact factor: 4.638

3.  [Can the implantable collamer lens with AquaPORT technology safely prevent an angle block? Early experiences in the Homburg/Saar refractive surgery center].

Authors:  T Tsintarakis; T Eppig; A Langenbucher; B Seitz; M El-Husseiny
Journal:  Ophthalmologe       Date:  2015-05       Impact factor: 1.059

4.  Full anterior segment biometry with extended imaging range spectral domain optical coherence tomography at 1340 nm.

Authors:  Peng Li; Murray Johnstone; Ruikang K Wang
Journal:  J Biomed Opt       Date:  2014-04       Impact factor: 3.170

5.  Anterior segment dimensions in Asian and Caucasian eyes measured by optical coherence tomography.

Authors:  Bing Qin; Maolong Tang; Yan Li; Xinbo Zhang; Renyuan Chu; David Huang
Journal:  Ophthalmic Surg Lasers Imaging       Date:  2012-02-09

6.  Role of anterior segment optical coherence tomogram in Descemet's membrane detachment.

Authors:  Sonia Kothari; Kulin Kothari; Rajul S Parikh
Journal:  Indian J Ophthalmol       Date:  2011 Jul-Aug       Impact factor: 1.848

Review 7.  Innovations in pediatric cataract surgery.

Authors:  Sudarshan Kumar Khokhar; Ganesh Pillay; Esha Agarwal; Manish Mahabir
Journal:  Indian J Ophthalmol       Date:  2017-03       Impact factor: 1.848

8.  Relative position of the central hole after EVO-ICL implantation for moderate to high myopia.

Authors:  Xiaojian He; Lingling Niu; Huamao Miao; Feng Zhao; Xingtao Zhou
Journal:  BMC Ophthalmol       Date:  2020-07-28       Impact factor: 2.209

9.  Assessment of anterior segment parameters under photopic and scotopic conditions in Indian eyes using anterior segment optical coherence tomography.

Authors:  Shaun Dacosta; Gitanjali Fernandes; Babu Rajendran; P Janakiraman
Journal:  Indian J Ophthalmol       Date:  2008 Jan-Feb       Impact factor: 1.848

10.  Endothelial distance after phakic iris-fixated intraocular lens implantation: a new safety reference.

Authors:  Tiago Bravo Ferreira; Joana Portelinha
Journal:  Clin Ophthalmol       Date:  2014-01-17
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.