Literature DB >> 15332397

Automatic CPAP titration with different self-setting devices in patients with obstructive sleep apnoea.

A Stammnitz1, A Jerrentrup, T Penzel, J H Peter, C Vogelmeier, H F Becker.   

Abstract

Autotitrating continuous positive airway pressure (CPAP) devices automatically adjust the pressure according to upper airway obstructions. The aim of this study was to compare the treatment effects of different automatic CPAP devices (AutoSet, Horizon and Virtuoso) with conventional CPAP in patients with obstructive sleep apnoea independently of financial manufacturer support. Twelve male patients with obstructive sleep apnoea were submitted to a crossover study protocol with overnight polysomnography for 6 consecutive nights. After diagnostic polysomnography, the CPAP pressure was manually titrated. Over the next 4 nights, the patients were treated with any one of the three automatic CPAP devices or fixed CPAP in random order. The apnoea/hypopnoea index on the diagnostic night was 67.3+/-21.7 events h(-1), and was significantly reduced to 0.7+/-1.2, 3.0+/-2.9, 2.3+/-2.5 and 12.0+/-13.6 events x h(-1) with the fixed CPAP, AutoSet, Horizon and Virtuoso devices respectively. An apnoea/ hypopnoea index of <5 events h(-1), an indicator of optimal treatment, was achieved in all patients with fixed CPAP and in 10 patients using the Autoset and Horizon devices, but in only six of the 12 using the Virtuoso. The mean pressure was significantly lower with the AutoSet and Virtuoso devices, but not with the Horizon as compared to fixed CPAP. The maximum pressure was significantly higher with the Horizon. It is concluded that automatic continuous positive airway pressure devices produce a significant reduction in apnoea/hypopnoea index; however, there is considerable difference in the efficacy of the various devices.

Entities:  

Mesh:

Year:  2004        PMID: 15332397     DOI: 10.1183/09031936.04.00074304

Source DB:  PubMed          Journal:  Eur Respir J        ISSN: 0903-1936            Impact factor:   16.671


  11 in total

Review 1.  Canadian Thoracic Society 2011 guideline update: diagnosis and treatment of sleep disordered breathing.

Authors:  John Fleetham; Najib Ayas; Douglas Bradley; Michael Fitzpatrick; Thomas K Oliver; Debra Morrison; Frank Ryan; Frederick Series; Robert Skomro; Willis Tsai
Journal:  Can Respir J       Date:  2011 Jan-Feb       Impact factor: 2.409

2.  CPAP pressure requirements for obstructive sleep apnea patients at varying altitudes.

Authors:  David S Patz; Bruce Swihart; David P White
Journal:  Sleep       Date:  2010-05       Impact factor: 5.849

3.  Autoadjusting positive pressure trial in adults with sleep apnea assessed by a simplified diagnostic approach.

Authors:  Luis Torre-Bouscoulet; María Sonia Meza-Vargas; Armando Castorena-Maldonado; Margarita Reyes-Zúñeiga; Rogelio Pérez-Padilla
Journal:  J Clin Sleep Med       Date:  2008-08-15       Impact factor: 4.062

4.  Accuracy of autotitrating CPAP to estimate the residual Apnea-Hypopnea Index in patients with obstructive sleep apnea on treatment with autotitrating CPAP.

Authors:  Himanshu Desai; Anil Patel; Pinal Patel; Brydon J B Grant; M Jeffery Mador
Journal:  Sleep Breath       Date:  2009-05-01       Impact factor: 2.816

5.  Practice parameters for the use of autotitrating continuous positive airway pressure devices for titrating pressures and treating adult patients with obstructive sleep apnea syndrome: an update for 2007. An American Academy of Sleep Medicine report.

Authors:  Timothy I Morgenthaler; R Nisha Aurora; Terry Brown; Rochelle Zak; Cathy Alessi; Brian Boehlecke; Andrew L Chesson; Leah Friedman; Vishesh Kapur; Rama Maganti; Judith Owens; Jeffrey Pancer; Todd J Swick
Journal:  Sleep       Date:  2008-01       Impact factor: 5.849

6.  Polysomnographic parameters during non-rapid eye movement sleep predict continuous positive airway pressure adherence.

Authors:  Tetsurou Hoshino; Ryujiro Sasanabe; Kenta Murotani; Mariko Arimoto; Shuntaro Inagawa; Tohru Tanigawa; Yasue Uchida; Tetsuya Ogawa; Hiromi Ueda; Toshiaki Shiomi
Journal:  Nagoya J Med Sci       Date:  2016-05       Impact factor: 1.131

7.  Pressure modification or humidification for improving usage of continuous positive airway pressure machines in adults with obstructive sleep apnoea.

Authors:  Barry Kennedy; Toby J Lasserson; Dariusz R Wozniak; Ian Smith
Journal:  Cochrane Database Syst Rev       Date:  2019-12-02

8.  Reliability of home CPAP titration with different automatic CPAP devices.

Authors:  Frédéric Sériès; Julie Plante; Yves Lacasse
Journal:  Respir Res       Date:  2008-07-24

9.  Obstructive sleep apnea - management update.

Authors:  Craig A Hukins
Journal:  Neuropsychiatr Dis Treat       Date:  2006-09       Impact factor: 2.570

Review 10.  Treatment of sleep-disordered breathing with positive airway pressure devices: technology update.

Authors:  Karin Gardner Johnson; Douglas Clark Johnson
Journal:  Med Devices (Auckl)       Date:  2015-10-23
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.