Parallel acquisition techniques in cardiac cine magnetic resonance imaging using TrueFISP sequences: comparison of image quality and artifacts.

Peter Hunold1, Stefan Maderwald, Mark E Ladd, Vladimir Jellus, Jörg Barkhausen.   

Abstract

PURPOSE: To compare image quality, artifacts, and signal-to-noise ratio (SNR) in cardiac cine TrueFISP magnetic resonance imaging (MRI) with and without parallel acquisition techniques (PAT).
MATERIALS AND METHODS: MRI was performed in 16 subjects with a TrueFISP sequence (1.5 T; Magnetom Sonata, Siemens): TR, 3.0 msec; TE, 1.5 msec; flip angle (FA), 60 degrees. Three axes were scanned without PAT (no PAT) and using the generalized autocalibrating partially parallel acquisition (GRAPPA) and modified sensitivity encoding (mSENSE) reconstruction algorithms with an autocalibration mode to reduce scan time. A conventional spine array and a body flex array were used. Artifacts, image noise, and overall image quality were classified on a 4-point scale by an observer blinded to the implemented technique; for quantitative comparison, SNR was measured.
RESULTS: With a PAT factor of two, acquisition time could be reduced by 39%. No PAT did not show artifacts, and GRAPPA revealed fewer artifacts than mSENSE. PAT provided inferior-quality scores concerning image noise and overall image quality. In quantitative measurements, GRAPPA and mSENSE (20.1 +/- 6.2 and 15.6 +/- 6.2, respectively) yielded lower SNR than no PAT (30.6 +/- 20.1; P < 0.05) and P < 0.001).
CONCLUSION: Time savings in PAT are accompanied by artifacts and an increase in image noise. The GRAPPA algorithm was superior to mSENSE concerning image quality, noise, and SNR. Copyright 2004 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2004        PMID: 15332260     DOI: 10.1002/jmri.20125

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  13 in total

1.  Dual breath-hold magnetic resonance cine evaluation of global and regional cardiac function.

Authors:  Bernd J Wintersperger; Spencer Sincleair; Val M Runge; Olaf Dietrich; Armin Huber; Maximilian F Reiser; Stefan O Schoenberg
Journal:  Eur Radiol       Date:  2006-04-22       Impact factor: 5.315

2.  Single breath-hold magnetic resonance cine imaging for fast assessment of global and regional left ventricular function in clinical routine.

Authors:  Kai Nassenstein; Holger Eberle; Stefan Maderwald; Christoph J Jensen; Christina Heilmaier; Thomas Schlosser; Oliver Bruder
Journal:  Eur Radiol       Date:  2010-06-09       Impact factor: 5.315

3.  A radial self-calibrated (RASCAL) generalized autocalibrating partially parallel acquisition (GRAPPA) method using weight interpolation.

Authors:  Noel C F Codella; Pascal Spincemaille; Martin Prince; Yi Wang
Journal:  NMR Biomed       Date:  2010-12-28       Impact factor: 4.044

4.  Comparison of generalized autocalibrating partially parallel acquisitions and modified sensitivity encoding for diffusion tensor imaging.

Authors:  Y A Bhagat; D J Emery; S Naik; T Yeo; C Beaulieu
Journal:  AJNR Am J Neuroradiol       Date:  2007-02       Impact factor: 3.825

5.  A study of in vitro and in vivo MR of free-breathing whole-heart 3D coronary angiography using parallel imaging.

Authors:  Hang Jin; Meng-Su Zeng; Mei-Ying Ge; Shan Yang; Cai-Zhong Chen; Ji-Zhang Shen; Ren-Chen Li
Journal:  Int J Cardiovasc Imaging       Date:  2009-01-15       Impact factor: 2.357

Review 6.  Recent advances in parallel imaging for MRI.

Authors:  Jesse Hamilton; Dominique Franson; Nicole Seiberlich
Journal:  Prog Nucl Magn Reson Spectrosc       Date:  2017-05-02       Impact factor: 9.795

7.  A new perceptual difference model for diagnostically relevant quantitative image quality evaluation: a preliminary study.

Authors:  Jun Miao; Feng Huang; Sreenath Narayan; David L Wilson
Journal:  Magn Reson Imaging       Date:  2012-12-05       Impact factor: 2.546

8.  Detection of infragenual arterial disease using non-contrast-enhanced MR angiography in patients with diabetes.

Authors:  Xin Liu; Na Zhang; Zhaoyang Fan; Fei Feng; Qi Yang; Hairong Zheng; Pengcheng Liu; Debiao Li
Journal:  J Magn Reson Imaging       Date:  2013-11-08       Impact factor: 4.813

9.  Non-Contrast Enhanced MR Angiography (NCE-MRA) of the Calf: A Direct Comparison between Flow-Sensitive Dephasing (FSD) Prepared Steady-State Free Precession (SSFP) and Quiescent-Interval Single-Shot (QISS) in Patients with Diabetes.

Authors:  Na Zhang; Liqiu Zou; Yi Huang; Dexiang Liu; Yukuan Tang; Zhaoyang Fan; Hanwei Chen; Xin Liu
Journal:  PLoS One       Date:  2015-06-02       Impact factor: 3.240

Review 10.  Accelerated CMR using zonal, parallel and prior knowledge driven imaging methods.

Authors:  Sebastian Kozerke; Sven Plein
Journal:  J Cardiovasc Magn Reson       Date:  2008-06-05       Impact factor: 5.364

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.