Literature DB >> 15311143

Temporal stability of twenty-four-hour ambulatory hemodynamic bioimpedance measures in African American adolescents.

Vernon A Barnes1, Maribeth H Johnson, Frank A Treiber.   

Abstract

BACKGROUND: The reliability of ambulatory impedance cardiography has not been evaluated.
OBJECTIVE: The purpose of this study was to determine the reproducibility of daytime and night-time ambulatory bioimpedance-derived measures of hemodynamic function in youth.
METHODS: Thirty-five African American adolescents (ages 16.2+/-1.4 years, 14 girls, 21 boys) with high normal systolic resting blood pressure (BP) were evaluated twice, separated by a 2-month interval. Measures were collected using the AIM-8-V3 Wearable Cardiac Performance Monitor (Bio-impedance Technology, Inc., Chapel Hill, North Carolina, USA) and the Spacelabs ambulatory BP monitor 90207 (Spacelabs Inc., Redmond, Washington, USA) from 0600 h to midnight every 20 min and from midnight to 0600 h every 30 min in the natural environment.
RESULTS: There were no significantly different means (P>0.15) between the two visits for daytime ambulatory heart rate (HR, r = 0.81), stroke volume (SV, r = 0.54), cardiac output (CO, r = 0.56), pre-ejection period (PEP, r = 0.59), left ventricular ejection time (LVET, r = 0.74), Heather Index (HI, r = 0.79), systolic BP (SBP, r = 0.79), diastolic BP (DBP, r = 0.66), mean arterial pressure (MAP, r = 0.65) and total peripheral resistance (TPR, r = 0.47). Overall means for night-time ambulatory HR (r = 0.76), SV (r = 0.49), CO (r = 0.45), LVET (r = 0.43), HI (r = 0.82), SBP (r = 0.65), DBP (r = 0.62), MAP (r = 0.63) and TPR (r = 0.20) were not significantly different between visits (P > 0.06). Mean differences (P < 0.01) were observed for PEP (r = 0.57).
CONCLUSIONS: The findings demonstrate that across 2 months in youth daytime and night-time ambulatory bioimpedance-derived measures of HR, HI, SBP, DBP and MAP are highly repeatable and SV, CO, PEP and LVET are moderately repeatable. This methodology should prove useful in cardiovascular research and clinical care.

Entities:  

Mesh:

Year:  2004        PMID: 15311143      PMCID: PMC3292177          DOI: 10.1097/00126097-200408000-00001

Source DB:  PubMed          Journal:  Blood Press Monit        ISSN: 1359-5237            Impact factor:   1.444


  27 in total

1.  A meta-analysis of published studies concerning the validity of thoracic impedance cardiography.

Authors:  E Raaijmakers; T J Faes; R J Scholten; H G Goovaerts; R M Heethaar
Journal:  Ann N Y Acad Sci       Date:  1999-04-20       Impact factor: 5.691

2.  Ambulatory impedance cardiography: new possibilities.

Authors:  G Cybulski
Journal:  J Appl Physiol (1985)       Date:  2000-04

3.  Pediatric impedance cardiography: temporal stability and intertask consistency.

Authors:  J J McGrath; W H O'Brien
Journal:  Psychophysiology       Date:  2001-05       Impact factor: 4.016

4.  Reproducibility of ambulatory blood pressure measures in African-American adolescents.

Authors:  Vernon A Barnes; Maribeth H Johnson; J Caroline Dekkers; Frank A Treiber
Journal:  Ethn Dis       Date:  2002       Impact factor: 1.847

5.  Large-scale ensemble averaging of ambulatory impedance cardiograms.

Authors:  Harriëtte Riese; Paul F C Groot; Mireille van den Berg; Nina H M Kupper; Ellis H B Magnee; Ellen J Rohaan; Tanja G M Vrijkotte; Gonneke Willemsen; Eco J C de Geus
Journal:  Behav Res Methods Instrum Comput       Date:  2003-08

6.  Impact of transcendental meditation on ambulatory blood pressure in African-American adolescents.

Authors:  Vernon A Barnes; Frank A Treiber; Maribeth H Johnson
Journal:  Am J Hypertens       Date:  2004-04       Impact factor: 2.689

7.  Motion artifact from spot and band electrodes during impedance cardiography.

Authors:  M H Qu; Y J Zhang; J G Webster; W J Tompkins
Journal:  IEEE Trans Biomed Eng       Date:  1986-11       Impact factor: 4.538

8.  Variability of thoracic impedance cardiograms in man.

Authors:  W M de Souza; R B Panerai
Journal:  Med Biol Eng Comput       Date:  1981-07       Impact factor: 2.602

9.  Reproducibility of cardiac output measurements by Doppler echocardiography in prepubertal children and adults.

Authors:  A Vinet; S Nottin; A M Lecoq; P Guenon; P Obert
Journal:  Int J Sports Med       Date:  2001-08       Impact factor: 3.118

10.  Impact of Transcendental Meditation on cardiovascular function at rest and during acute stress in adolescents with high normal blood pressure.

Authors:  V A Barnes; F A Treiber; H Davis
Journal:  J Psychosom Res       Date:  2001-10       Impact factor: 3.006

View more
  4 in total

1.  The reproducibility of heart rate recovery after treadmill exercise test.

Authors:  Erol Tulumen; Indira Khalilayeva; Kudret Aytemir; F E S C Ergun Baris Kaya; Onur Sinan Deveci; Hakan Aksoy; Ugur Kocabas; Sercan Okutucu; Lale Tokgozoglu; Giray Kabakci; Hilmi Ozkutlu; Ali Oto
Journal:  Ann Noninvasive Electrocardiol       Date:  2011-10       Impact factor: 1.468

2.  Clinical and Pre-clinical Applications of the Transcendental Meditation Program in the Prevention and Treatment of Essential Hypertension and Cardiovascular Disease in Youth and Adults.

Authors:  Vernon A Barnes; David W Orme-Johnson
Journal:  Curr Hypertens Rev       Date:  2006-08-01

3.  Prevention and Treatment of Cardiovascular Disease in Adolescents and Adults through the Transcendental Meditation(®) Program: A Research Review Update.

Authors:  Vernon A Barnes; David W Orme-Johnson
Journal:  Curr Hypertens Rev       Date:  2012-08

4.  Differential Impact of Stress Reduction Programs upon Ambulatory Blood Pressure among African American Adolescents: Influences of Endothelin-1 Gene and Chronic Stress Exposure.

Authors:  Mathew J Gregoski; Vernon A Barnes; Martha S Tingen; Yanbin Dong; Haidong Zhu; Frank A Treiber
Journal:  Int J Hypertens       Date:  2011-11-24       Impact factor: 2.420

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.