Literature DB >> 11531037

Reproducibility of cardiac output measurements by Doppler echocardiography in prepubertal children and adults.

A Vinet1, S Nottin, A M Lecoq, P Guenon, P Obert.   

Abstract

The aim of this study was to examine reproducibility of stroke volume and cardiac output measurements by Doppler echocardiography during submaximal and maximal exercise in adults and children. Fourteen healthy children (8 girls and 6 boys aged 10.9 +/- 0.9yr) and eleven healthy young adults (1 female and 10 males aged 22.3 +/- 3.8 yr) underwent a progressive maximal upright cycle test until exhaustion with estimation of stroke volume and cardiac output by Doppler echocardiography on two separate occasions (one week apart). Maximal oxygen uptake and maximal heart rate were not significantly different between both tests in the children and adults indicating that similar exhaustive efforts were achieved at each test. No significant differences for mean values of stroke volume and cardiac output were observed at rest in the children and whatever the exercise intensity in the children and adults. No significant differences were observed between values of root mean square (precision and precision of error) in both groups. Thus we demonstrated that stroke volume and cardiac output values obtained by Doppler echocardiography at rest and during submaximal and maximal exercise were reproducible on test-retest measurements in children and adults.

Entities:  

Mesh:

Year:  2001        PMID: 11531037     DOI: 10.1055/s-2001-16241

Source DB:  PubMed          Journal:  Int J Sports Med        ISSN: 0172-4622            Impact factor:   3.118


  6 in total

Review 1.  Doppler echocardiography for the estimation of cardiac output with exercise.

Authors:  Thomas Rowland; Philippe Obert
Journal:  Sports Med       Date:  2002       Impact factor: 11.136

2.  Left ventricles of aging athletes: better untwisters but not more relaxed during exercise.

Authors:  Claire Maufrais; G Doucende; T Rupp; M Dauzat; P Obert; S Nottin; I Schuster
Journal:  Clin Res Cardiol       Date:  2017-06-24       Impact factor: 5.460

3.  Reliability of Peak Exercise Stroke Volume Assessment by Impedance Cardiography in Patients with Residual Right Outflow Tract Lesions After Congenital Heart Disease Repair.

Authors:  Antoine Legendre; D Bonnet; L Bosquet
Journal:  Pediatr Cardiol       Date:  2017-09-25       Impact factor: 1.655

4.  Reliability of peak VO(2) and maximal cardiac output assessed using thoracic bioimpedance in children.

Authors:  Joanne Welsman; Katie Bywater; Colin Farr; Deborah Welford; Neil Armstrong
Journal:  Eur J Appl Physiol       Date:  2005-05-26       Impact factor: 3.078

5.  Evaluation of cardiac output from a tidally ventilated homogeneous lung model.

Authors:  Habib Benallal; Kenneth C Beck; Bruce D Johnson; Thierry Busso
Journal:  Eur J Appl Physiol       Date:  2005-07-20       Impact factor: 3.078

6.  Temporal stability of twenty-four-hour ambulatory hemodynamic bioimpedance measures in African American adolescents.

Authors:  Vernon A Barnes; Maribeth H Johnson; Frank A Treiber
Journal:  Blood Press Monit       Date:  2004-08       Impact factor: 1.444