Technical note: output and energy fluctuations of the tomotherapy Hi-Art helical tomotherapy system.

Stephen L Mahan1, Daniel J Chase, Chester R Ramsey.   

Abstract

The output and energy calibrations for the first clinical Hi-Art 2.0 helical tomotherapy system have been reviewed. Fixed-gantry/fixed-couch and rotational-gantry/fixed-couch measurements were made on a daily basis over a period of 20 weeks to investigate system stability. Static gantry measurements were taken at 10 cm depth in a rectangular stack of Virtual Water at an SSD distance of 90 cm and a field size of 5 x 40 cm. Rotational gantry measurements were taken in a cylindrical phantom Virtual Water phantom for a field size of 5 x 40 cm. The Hi-Art 2.0 system has maintained its calibration to within +/-2% and energy to within +/- 1.5% over the initial 20 week period.

Entities:  

Mesh:

Year:  2004        PMID: 15305465     DOI: 10.1118/1.1763007

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

1.  The report of Task Group 100 of the AAPM: Application of risk analysis methods to radiation therapy quality management.

Authors:  M Saiful Huq; Benedick A Fraass; Peter B Dunscombe; John P Gibbons; Geoffrey S Ibbott; Arno J Mundt; Sasa Mutic; Jatinder R Palta; Frank Rath; Bruce R Thomadsen; Jeffrey F Williamson; Ellen D Yorke
Journal:  Med Phys       Date:  2016-07       Impact factor: 4.071

2.  Retrospective study on performance of constancy check device in Linac beam monitoring using Statistical Process Control.

Authors:  Bipasha Pal; Angshuman Pal; Suresh Das; Soura Palit; Papai Sarkar; Subhayan Mondal; Suman Mallik; Jyotirup Goswami; Sayan Das; Arijit Sen; Monidipa Mondol
Journal:  Rep Pract Oncol Radiother       Date:  2019-12-10

3.  Technical evaluation of TomoTherapy automatic roll correction.

Authors:  Steve Laub; Michael Snyder; Jay Burmeister
Journal:  J Appl Clin Med Phys       Date:  2015-05-08       Impact factor: 2.102

4.  Initial dosimetric experience with mega voltage computed tomography detectors and estimation of pre and post-repair dosimetric parameters of a first Helical Hi-Art II tomotherapy machine in India.

Authors:  Rajesh A Kinhikar; Zubin Master; Dipak S Dhote; Deepak D Deshpande
Journal:  J Med Phys       Date:  2009-04

5.  Out-of-field dosimetry measurements for a helical tomotherapy system.

Authors:  Chester Ramsey; Rebecca Seibert; Stephen L Mahan; Dharmin Desai; Daniel Chase
Journal:  J Appl Clin Med Phys       Date:  2006-08-24       Impact factor: 2.102

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.