Literature DB >> 15291029

A biomechanical comparison of supplementary posterior translaminar facet and transfacetopedicular screw fixation after anterior lumbar interbody fusion.

Sung-Min Kim1, T Jesse Lim, Josemaria Paterno, Daniel H Kim.   

Abstract

OBJECT: Facet screw fixation is the lowest profile lumbar stabilization method. In this study the immediate biomechanical stability provided by the two different types of fixation are compared: translaminar facet screw (TLFS) and transfacetopedicular screw (TFPS) placement after anterior lumbar interbody fusion (ALIF) using a femoral ring allograft. Both facet screw fixation types were also compared with the gold standard, transpedicular screw and rod (TSR) fixation.
METHODS: Twenty-four human lumbosacral spines were tested in the following sequence: intact state, after discectomy, after ALIF, and after TLFS, TFPS, or TSR fixation. Intervertebral motions were measured by a video-based motion capture system. The range of motion (ROM) and neutral zone (NZ) were compared for each loading to a maximum of 7.5 Nm. The ROMs for stand-alone ALIFs were less than but similar to those of the intact spine, but NZs were slightly increased in all modes. The ROMs for both TLFS and TFPS fixation were significantly decreased from those of the intact spine in all modes and those of the stand-alone ALIF in flexion and extension. The TLFS and TFPS fixations significantly reduced NZs to below that of the intact spine in all modes. Compared with NZs for ALIF, both types of fixation revealed significantly lower values, except for TLFS placement in lateral bending and TFPS fixation in lateral bending and rotation. There were no significant differences between TLFS and TFPS fixation. There were also no significant differences among both TLFS and TFPS and TSR fixations, except that TFPS was inferior to TSR in lateral bending.
CONCLUSIONS: Stand-alone ALIF may not provide sufficient stability. Both facet fixations produced significant additional stability and both are comparable to TSR fixation. Although TFPS fixation revealed a slightly inferior result, TFPSs can be placed percutaneously with the assistance of fluoroscopic guidance and it makes the posterior facet fixation minimally invasive. Therefore, the TFPS fixation can be considered as a good alternative to TLFS fixation.

Entities:  

Mesh:

Year:  2004        PMID: 15291029     DOI: 10.3171/spi.2004.1.1.0101

Source DB:  PubMed          Journal:  J Neurosurg Spine        ISSN: 1547-5646


  9 in total

1.  The combined use of unilateral pedicle screw and contralateral facet joint screw fixation in transforaminal lumbar interbody fusion.

Authors:  Yuanwu Cao; Zixian Chen; Chun Jiang; Shengcheng Wan; Xiaoxing Jiang; Zhenzhou Feng
Journal:  Eur Spine J       Date:  2015-07-15       Impact factor: 3.134

2.  Prospective evaluation of 1-year outcomes in single-level percutaneous lumbar transfacet screw fixation in the lateral decubitus position following lateral transpsoas interbody fusion.

Authors:  Jay W Rhee; Rory J Petteys; Amjad N Anaizi; Faheem A Sandhu; Jean-Marc Voyadzis
Journal:  Eur Spine J       Date:  2015-04-18       Impact factor: 3.134

3.  Transfacet screws using spinal navigation in addition to anterior or oblique lumbar interbody fusion: technical note and preliminary results.

Authors:  Antoine Gennari; Amandine Gavotto; Fabien Almairac; Yann Pelletier; Philippe Paquis; Stéphane Litrico
Journal:  Eur J Orthop Surg Traumatol       Date:  2021-02-01

4.  Biomechanical assessment of unilateral pedicle screws plus contralateral transfacetopedicular screws after transforaminal lumbar interbody fusion with two cages.

Authors:  Zhong-Lin Xue; Zhong-Xian Chen; Chao-Hua Fu; Hong-Jun Lei; Xiang-Wei Yuan
Journal:  Orthop Surg       Date:  2013-11       Impact factor: 2.071

5.  Non-fusion instrumentation of the lumbar spine with a hinged pedicle screw rod system: an in vitro experiment.

Authors:  Werner Schmoelz; U Onder; A Martin; A von Strempel
Journal:  Eur Spine J       Date:  2009-06-06       Impact factor: 3.134

6.  CT- and fluoroscopy-guided percutaneous screw fixation of a "carrot-stick" spinal fracture in an elderly man with ankylosing spondylitis.

Authors:  Laurent Huwart; Nicolas Amoretti
Journal:  Skeletal Radiol       Date:  2013-07-11       Impact factor: 2.199

7.  Oblique lateral interbody fusion combined with different internal fixations for the treatment of degenerative lumbar spine disease: a finite element analysis.

Authors:  Shuyi Zhang; Zhengpeng Liu; Chenshui Lu; Li Zhao; Chao Feng; Yahui Wang; Yilong Zhang
Journal:  BMC Musculoskelet Disord       Date:  2022-03-04       Impact factor: 2.362

8.  Trans-Endplate Pedicle Pillar System in Unstable Spinal Burst Fractures: Design, Technique, and Mechanical Evaluation.

Authors:  Chunfeng Zhao; Michio Hongo; Brice Ilharreborde; Kristin D Zhao; Bradford L Currier; Kai-Nan An
Journal:  PLoS One       Date:  2015-10-26       Impact factor: 3.240

9.  Trajectory of Lumbar Translaminar Facet Screw Under Navigation: A Cadaveric Study.

Authors:  Weerasak Singhatanadgige; Kittisak Songthong; Phattareeya Pholprajug; Wicharn Yingsakmongkol; Vit Kotheeranurak; Worawat Limthongkul
Journal:  Global Spine J       Date:  2020-10-14
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.