Literature DB >> 15282820

Off-resonance effects in the transient response of SSFP sequences.

Carl Ganter1.   

Abstract

A previously developed eigenvector formalism is adapted to off-resonance in the transient response of quasiperiodic steady-state free precession (SSFP) sequences, including TrueFISP as a special case. The effective relaxation rates for essentially parallel and perpendicular deviations from the steady state are determined analytically in leading order perturbation theory. The latter are a known cause of oscillatory artifacts and therefore constitute the main target of a variety of preparation techniques. In addition, the former also play a dominating role in applications such as inversion recovery (IR) TrueFISP, which intentionally measure far away from the equilibrium. For both components, the approach toward equilibrium turns out to depend sensitively on field inhomogeneities, especially for smaller ratios of T2/T1. For the perpendicular deviations, the calculations show that--except very close to banding artifacts, where the steady-state signal is almost zero--field inhomogeneities additionally increase their effective relaxation rate almost as much as in the free induction decay (FID). The analytical results are tested against numerical simulation and MR measurements.

Mesh:

Year:  2004        PMID: 15282820     DOI: 10.1002/mrm.20173

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  4 in total

1.  Optimized quantification of spin relaxation times in the hybrid state.

Authors:  Jakob Assländer; Riccardo Lattanzi; Daniel K Sodickson; Martijn A Cloos
Journal:  Magn Reson Med       Date:  2019-06-12       Impact factor: 4.668

2.  Prediction of myocardial signal during CINE balanced SSFP imaging.

Authors:  Kyunghyun Sung; Hsu-Lei Lee; Houchun H Hu; Krishna S Nayak
Journal:  MAGMA       Date:  2010-03-13       Impact factor: 2.310

3.  Balanced SSFP transient imaging using variable flip angles for a predefined signal profile.

Authors:  Pauline W Worters; Brian A Hargreaves
Journal:  Magn Reson Med       Date:  2010-11       Impact factor: 4.668

4.  Non-contrast-enhanced 4D MR angiography with STAR spin labeling and variable flip angle sampling: a feasibility study for the assessment of Dural Arteriovenous Fistula.

Authors:  Jinhee Jang; Peter Schmitt; Bom-yi Kim; Hyun Seok Choi; So-Lyung Jung; Kook-Jin Ahn; Inseong Kim; Munyoung Paek; Bum-soo Kim
Journal:  Neuroradiology       Date:  2014-02-14       Impact factor: 2.804

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.