Literature DB >> 20632411

Balanced SSFP transient imaging using variable flip angles for a predefined signal profile.

Pauline W Worters1, Brian A Hargreaves.   

Abstract

Variable flip angles are used in steady-state free precession (SSFP) acquisitions (e.g., time-of-flight) but to a lesser extent than in spin echo acquisitions. In balanced steady-state free precession, imaging is often assumed to occur during the steady state, which has been well described in the literature. However, in many cases, imaging occurs during the transient stage, and the use of variable flip angles can improve signal and thus image quality. Here, we present the calculation of flip angles in transient balanced steady-state free precession to generate a predefined signal profile. The signal profile was iteratively optimized to maximize the integral of the signal versus time curve. The key contribution of this work is the formulation of the flip angle as a deterministic function of the preceding and desired magnetization. Catalyzation schemes, e.g., Kaiser-windowed ramp, can be combined with variable flip angles balanced steady-state free precession to reduce signal oscillations. A uniform signal profile was used as an example to demonstrate the variable flip angle algorithm. Accuracy of the algorithm and Bloch simulations were verified with MRI phantom acquisitions. Renal angiograms were acquired using an inflow-based balanced steady-state free precession MR angiography technique; improved small-vessel depiction was observed in volunteer examinations.
Copyright © 2010 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2010        PMID: 20632411      PMCID: PMC2965793          DOI: 10.1002/mrm.22541

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  20 in total

1.  Characterization and reduction of the transient response in steady-state MR imaging.

Authors:  B A Hargreaves; S S Vasanawala; J M Pauly; D G Nishimura
Journal:  Magn Reson Med       Date:  2001-07       Impact factor: 4.668

2.  Multiecho sequences with variable refocusing flip angles: optimization of signal behavior using smooth transitions between pseudo steady states (TRAPS).

Authors:  Juergen Hennig; Matthias Weigel; Klaus Scheffler
Journal:  Magn Reson Med       Date:  2003-03       Impact factor: 4.668

3.  On the transient phase of balanced SSFP sequences.

Authors:  Klaus Scheffler
Journal:  Magn Reson Med       Date:  2003-04       Impact factor: 4.668

4.  Calculation of flip angles for echo trains with predefined amplitudes with the extended phase graph (EPG)-algorithm: principles and applications to hyperecho and TRAPS sequences.

Authors:  Juergen Hennig; Matthias Weigel; Klaus Scheffler
Journal:  Magn Reson Med       Date:  2004-01       Impact factor: 4.668

5.  Reduction of transient signal oscillations in true-FISP using a linear flip angle series magnetization preparation.

Authors:  Vibhas S Deshpande; Yiu-Cho Chung; Qiang Zhang; Steven M Shea; Debiao Li
Journal:  Magn Reson Med       Date:  2003-01       Impact factor: 4.668

Review 6.  Principles and applications of balanced SSFP techniques.

Authors:  Klaus Scheffler; Stefan Lehnhardt
Journal:  Eur Radiol       Date:  2003-08-20       Impact factor: 5.315

7.  Reduced RF power without blurring: correcting for modulation of refocusing flip angle in FSE sequences.

Authors:  Reed F Busse
Journal:  Magn Reson Med       Date:  2004-05       Impact factor: 4.668

8.  Multiple-readout selective inversion recovery angiography.

Authors:  S J Wang; D G Nishimura; A Macovski
Journal:  Magn Reson Med       Date:  1991-01       Impact factor: 4.668

9.  A simple geometrical description of the TrueFISP ideal transient and steady-state signal.

Authors:  P Schmitt; M A Griswold; V Gulani; A Haase; M Flentje; P M Jakob
Journal:  Magn Reson Med       Date:  2006-01       Impact factor: 4.668

Review 10.  Nonenhanced MR angiography.

Authors:  Mitsue Miyazaki; Vivian S Lee
Journal:  Radiology       Date:  2008-07       Impact factor: 11.105

View more
  4 in total

1.  Rapid B1 mapping using orthogonal, equal-amplitude radio-frequency pulses.

Authors:  Yulin V Chang
Journal:  Magn Reson Med       Date:  2011-06-28       Impact factor: 4.668

2.  Magnetic resonance imaging with gradient sound respiration guide.

Authors:  Naoharu Kobayashi
Journal:  PLoS One       Date:  2021-07-19       Impact factor: 3.240

3.  Optimization of 4D vessel-selective arterial spin labeling angiography using balanced steady-state free precession and vessel-encoding.

Authors:  Thomas W Okell; Peter Schmitt; Xiaoming Bi; Michael A Chappell; Rob H N Tijssen; Fintan Sheerin; Karla L Miller; Peter Jezzard
Journal:  NMR Biomed       Date:  2016-04-13       Impact factor: 4.044

4.  Optimal control design of turbo spin-echo sequences with applications to parallel-transmit systems.

Authors:  Alessandro Sbrizzi; Hans Hoogduin; Joseph V Hajnal; Cornelis A T van den Berg; Peter R Luijten; Shaihan J Malik
Journal:  Magn Reson Med       Date:  2016-01-22       Impact factor: 4.668

  4 in total