Influence of the use of Er:YAG laser for cavity preparation and surface treatment in microleakage of resin-modified glass ionomer restorations.

Michelle A Chinelatti1, Renata P Ramos, Daniela T Chimello, Maria C Borsatto, Jesus D Pécora, Regina G Palma-Dibb.   

Abstract

This study quantitatively assessed the amount of microleakage on Class V cavities prepared by Er:YAG laser and high-speed handpiece, varying the surface treatment and restoring with a resin-modified glass ionomer cement. Fifty cavities were prepared using either an Er:YAG laser device or a carbide bur at high speed. The surface treatment was performed as follows: Er:YAG laser irradiation (G1); 40% polyacrylic acid (G2); laser + acid (G3); finishing with low speed + laser + acid (G4); conventional bur preparation + acid (G5-control). The samples were restored with Fuji II LC, thermocycled, isolated and immersed in a 50% AgNO3 solution. The restorations were serially sectioned and the extent of dye penetration was measured in milimeters using specific computer software. Data were analyzed by two-way ANOVA and Tukey test. The lowest degree of microleakage was observed for G5, which was statistically similar (p>0.05) to G4 but different (p<0.05) from all the other experiental groups. Lesser microleakage was observed at the occlusal margins than at the cervical margins (p<0.05). It may be concluded that the use of Er:YAG laser for cavity preparation and surface treatment negatively affected the marginal sealing of resin-modified glass ionomer restorations.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15279483

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  15 in total

1.  Comparison of the Er,Cr:YSGG laser with a chemical vapour deposition bur and conventional techniques for cavity preparation: a microleakage study.

Authors:  A Rüya Yazici; Zeren Yıldırım; Sibel A Antonson; Evren Kilinc; Daniele Koch; Donald E Antonson; Berrin Dayangaç; Gül Ozgünaltay
Journal:  Lasers Med Sci       Date:  2010-09-15       Impact factor: 3.161

2.  Evaluation of the Morphological Characteristics of Laser-Irradiated Dentin.

Authors:  Barbara Cvikl; Bledar Lilaj; Alexander Franz; Daniela Degendorfer; Andreas Moritz
Journal:  Photomed Laser Surg       Date:  2015-09-21       Impact factor: 2.796

3.  Effect of erbium:yttrium-aluminum-garnet laser energies on superficial and deep dentin microhardness.

Authors:  Michelle Alexandra Chinelatti; Walter Raucci-Neto; Silmara Aparecida Milori Corona; Regina Guenka Palma-Dibb
Journal:  Lasers Med Sci       Date:  2008-11-04       Impact factor: 3.161

4.  Comparison of Micro-Leakage from Resin-Modified Glass Ionomer Restorations in Cavities Prepared by Er:YAG (Erbium-Doped Yttrium Aluminum Garnet) Laser and Conventional Method in Primary Teeth.

Authors:  Zahra Bahrololoomi; Forooghosadat Razavi; Ali Asghar Soleymani
Journal:  J Lasers Med Sci       Date:  2014

5.  Assessment of Microleakage of a Composite Resin Restoration in Primary Teeth Following Class III Cavity Preparation Using Er, Cr: YSGG laser: An In Vitro Study.

Authors:  Priya Subramaniam; Annu Pandey
Journal:  J Lasers Med Sci       Date:  2016-07-18

6.  Microleakage of Er:YAG laser and dental bur prepared cavities in primary teeth restored with different adhesive restorative materials.

Authors:  Ali Baghalian; Yahya B Nakhjavani; Tabassom Hooshmand; Pouria Motahhary; Hoda Bahramian
Journal:  Lasers Med Sci       Date:  2012-11-08       Impact factor: 3.161

7.  Effect of the erbium:yttrium-aluminum-garnet laser or diamond bur cavity preparation on the marginal microleakage of class V cavities restored with different adhesives and composite systems.

Authors:  Batu Can Yaman; Begum Efes Guray; Can Dorter; Yavuz Gomeç; Oktay Yazıcıoglu; Dina Erdilek
Journal:  Lasers Med Sci       Date:  2011-08-16       Impact factor: 3.161

8.  Vibrations produced during erbium:yttrium-aluminum-garnet laser irradiation.

Authors:  Ivica Anic; Ivana Miletic; Silvana Jukic Krmek; Josipa Borcic; Sonja Pezelj-Ribaric
Journal:  Lasers Med Sci       Date:  2008-08-12       Impact factor: 3.161

9.  Microleakage and scanning electron microscopy evaluation of all-in-one self-etch adhesives and their respective nanocomposites prepared by erbium:yttrium-aluminum-garnet laser and bur.

Authors:  Yonca Korkmaz; Emre Ozel; Nuray Attar; Ceren Ozge Bicer; Erhan Firatli
Journal:  Lasers Med Sci       Date:  2009-04-27       Impact factor: 3.161

10.  Microleakage of glass ionomer formulations after erbium:yttrium-aluminium-garnet laser preparation.

Authors:  Katleen I M Delmé; Peter J Deman; Mieke A A De Bruyne; Samir Nammour; Roeland J G De Moor
Journal:  Lasers Med Sci       Date:  2008-08-21       Impact factor: 3.161

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.