Literature DB >> 15269958

Image construction methods for phased array magnetic resonance imaging.

Deniz Erdogmus1, Rui Yan, Erik G Larsson, Jose C Principe, Jeffrey R Fitzsimmons.   

Abstract

PURPOSE: To study image construction in phased array magnetic resonance imaging (MRI) systems from a statistical signal processing point of view.
MATERIALS AND METHODS: Three new approaches for image combination with multiple coils are proposed: 1) one based on the singular value decomposition of the measurement matrix, which is asymptotically optimal in the signal-to-noise ratio sense; 2) one based on a maximum-likelihood formulation, incorporating a priori information on the coil sensitivities in a Bayesian manner; and 3) one based on a least-squares formulation, which incorporates a smoothness constraint on the coil sensitivities.
RESULTS: Numerical examples using synthetic and real data are presented to illustrate the performance of these new approaches. Results on the synthetic data show improvement in signal-to-error ratio, while results on the real data (a 4.7 T four-coil image of a cat spinal cord) show that the proposed methods can improve the SNR in the final image by up to 3 dB in the regions of interest compared to conventional sum-of-squares processing.
CONCLUSION: It is demonstrated that phased array MRI reconstruction performance can be improved by the use of more elaborate statistical signal processing algorithms. Copyright 2004 Wiley-Liss, Inc.

Mesh:

Year:  2004        PMID: 15269958     DOI: 10.1002/jmri.20115

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  7 in total

1.  Optimization of the number of selectable channels for spine phased array coils for transverse imaging.

Authors:  Susumu Moriya; Yukio Miki; Tsuneo Yokobayashi; Akira Yamamoto; Mitsunori Kanagaki; Yoshiaki Komori; Koji Fujimoto; Mitsunori Ishikawa
Journal:  Jpn J Radiol       Date:  2011-04-26       Impact factor: 2.374

2.  Phase reconstruction from multiple coil data using a virtual reference coil.

Authors:  Dennis L Parker; Allison Payne; Nick Todd; J Rock Hadley
Journal:  Magn Reson Med       Date:  2013-09-04       Impact factor: 4.668

3.  A Review of Non-1H RF Receive Arrays in Magnetic Resonance Imaging and Spectroscopy.

Authors:  Matthew Wilcox; Steven M Wright; Mary McDougall
Journal:  IEEE Open J Eng Med Biol       Date:  2020-10-13

4.  Effects of proximity and noise level of phased array coil elements on overall signal-to-noise in parallel MR spectroscopy.

Authors:  Candace C Fleischer; Xiaodong Zhong; Hui Mao
Journal:  Magn Reson Imaging       Date:  2017-12-05       Impact factor: 2.546

5.  Model-based iterative reconstruction for single-shot EPI at 7T.

Authors:  Uten Yarach; Myung-Ho In; Itthi Chatnuntawech; Berkin Bilgic; Frank Godenschweger; Hendrik Mattern; Alessandro Sciarra; Oliver Speck
Journal:  Magn Reson Med       Date:  2017-02-10       Impact factor: 4.668

6.  Phased-array combination for MR spectroscopic imaging using a water reference.

Authors:  Abas Abdoli; Andrew A Maudsley
Journal:  Magn Reson Med       Date:  2015-09-28       Impact factor: 4.668

7.  Optimized truncation to integrate multi-channel MRS data using rank-R singular value decomposition.

Authors:  Dongsuk Sung; Benjamin B Risk; Maame Owusu-Ansah; Xiaodong Zhong; Hui Mao; Candace C Fleischer
Journal:  NMR Biomed       Date:  2020-04-06       Impact factor: 4.044

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.