Literature DB >> 15262547

Contrast enhancement of short T2 tissues using ultrashort TE (UTE) pulse sequences.

M D Robson1, P D Gatehouse, P W So, J D Bell, G M Bydder.   

Abstract

AIM: To review the effects of contrast administration on tissues with short T2s using a pulse ultrashort echo time (UTE) sequence.
MATERIALS AND METHODS: Pulse sequences were implemented with echo times of 0.08 ms and three later gradient echoes. A fat-suppression option was used and later echo images were subtracted from the first echo image. Contrast enhancement with gadodiamide (0.3 mmol/kg) was used for serial studies in a volunteer. The images of 10 patients were reviewed for evidence of contrast enhancement in short T2 tissues.
RESULTS: Contrast enhancement was seen in normal meninges, falx, tendons, ligaments, menisci, periosteum and cortical bone. In addition more extensive enhancement than with conventional pulse sequences was seen in meningeal disease, intervertebral disc disease, periligamentous scar tissue and periosteum after fracture. Subtraction of an image taken with a longer TE from the first image was of value in differentiating enhancement in short T2 tissues from that in long T2 tissues or blood.
CONCLUSION: Contrast enhancement can be identified in tissues with short T2s using UTE pulse sequences in health and disease. Copyright 2004 The Royal College of Radiologists

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15262547     DOI: 10.1016/j.crad.2003.09.025

Source DB:  PubMed          Journal:  Clin Radiol        ISSN: 0009-9260            Impact factor:   2.350


  16 in total

1.  Review. The Agfa Mayneord lecture: MRI of short and ultrashort T₂ and T₂* components of tissues, fluids and materials using clinical systems.

Authors:  G M Bydder
Journal:  Br J Radiol       Date:  2011-12       Impact factor: 3.039

2.  UTE-T2∗ mapping detects sub-clinical meniscus injury after anterior cruciate ligament tear.

Authors:  A Williams; Y Qian; S Golla; C R Chu
Journal:  Osteoarthritis Cartilage       Date:  2012-01-18       Impact factor: 6.576

3.  Designing long-T2 suppression pulses for ultrashort echo time imaging.

Authors:  Peder E Z Larson; Paul T Gurney; Krishna Nayak; Garry E Gold; John M Pauly; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2006-07       Impact factor: 4.668

4.  Using adiabatic inversion pulses for long-T2 suppression in ultrashort echo time (UTE) imaging.

Authors:  Peder E Z Larson; Steven M Conolly; John M Pauly; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2007-11       Impact factor: 4.668

5.  Tendon and ligament imaging.

Authors:  R J Hodgson; P J O'Connor; A J Grainger
Journal:  Br J Radiol       Date:  2012-05-02       Impact factor: 3.039

6.  UTE MRI of the Osteochondral Junction.

Authors:  Won C Bae; Reni Biswas; Karen Chen; Eric Y Chang; Christine B Chung
Journal:  Curr Radiol Rep       Date:  2014-02-01

Review 7.  Quantitative magnetic resonance imaging of the lumbar intervertebral discs.

Authors:  Dosik Hwang; Sewon Kim; Nirusha A Abeydeera; Sheronda Statum; Koichi Masuda; Christine B Chung; Palanan Siriwanarangsun; Won C Bae
Journal:  Quant Imaging Med Surg       Date:  2016-12

Review 8.  Rapid gradient-echo imaging.

Authors:  Brian A Hargreaves
Journal:  J Magn Reson Imaging       Date:  2012-10-23       Impact factor: 4.813

Review 9.  Challenges and current methods for attenuation correction in PET/MR.

Authors:  Vincent Keereman; Pieter Mollet; Yannick Berker; Volkmar Schulz; Stefaan Vandenberghe
Journal:  MAGMA       Date:  2012-08-09       Impact factor: 2.310

10.  Correlation of meniscal T2* with multiphoton microscopy, and change of articular cartilage T2 in an ovine model of meniscal repair.

Authors:  M F Koff; P Shah; S Pownder; B Romero; R Williams; S Gilbert; S Maher; L A Fortier; S A Rodeo; H G Potter
Journal:  Osteoarthritis Cartilage       Date:  2013-05-13       Impact factor: 6.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.