In-vivo validation of on-line and off-line geometric coronary measurements using insertion of stenosis phantoms in porcine coronary arteries.

J Haase1, C Di Mario, C J Slager, W J van der Giessen, A den Boer, P J de Feyter, J H Reiber, P D Verdouw, P W Serruys.   

Abstract

Geometric coronary artery measurements with the Phillips Digital Cardiac Imaging System (DCI) and the Cardiovascular Angiography Analysis System (CAAS) were validated using percutaneous insertion of radiolucent stenosis phantoms in swine coronary arteries. Angiographic visualization of the stenosis lumens (phi 0.5, 0.7, 1.0, 1.4, 1.9 mm) was simultaneously recorded on DCI and cinefilm. The acquisition systems were calibrated by either the diameter of the guiding catheter (catheter CAL) or the isocenter method (isocenter CAL). Minimal luminal diameters (MLD) obtained with CAAS and DCI on 20 corresponding cineframes were compared with the true phantom diameters (PD). The accuracy of MLD measurements with the CAAS using isocenter CAL was -0.07mm, the precision 0.21 mm (r = 0.91; y = 0.30 + 0.79x; SEE = 0.19), with catheter CAL the accuracy was 0.09 mm, the precision 0.23 mm (r = 0.89; y = 0.19 + 0.74x; SEE = 0.19). The accuracy of MLD measurements using the DCI with isocenter CAL was 0.08 mm, the precision 0.15 min (r = 0.96; y = 0.08 + 0.86x; SEE = 0.14), with catheter CAL the accuracy was 0.18 mm, the precision 0.21 mm (r = 0.92; y = 0.09 + 0.76x; SEE = 0.17). DCI underestimated PD with isocenter CAL (p less than 0.05) and with catheter CAL (p less than 0.001). MLD can be measured with high accuracy, both applying on-line digital as well as off-line cineangiographic analysis. The results of digital measurements demonstrate high reliability of the new digital software package.

Entities:  

Mesh:

Year:  1992        PMID: 1525805     DOI: 10.1002/ccd.1810270106

Source DB:  PubMed          Journal:  Cathet Cardiovasc Diagn        ISSN: 0098-6569


  9 in total

1.  Coronary flow reserve in hypertrophic cardiomyopathy: relation with microvascular dysfunction and pathophysiological characteristics.

Authors:  M J Kofflard; M Michels; R Krams; M Kliffen; M L Geleijnse; F J Ten Cate; P W Serruys
Journal:  Neth Heart J       Date:  2007       Impact factor: 2.380

2.  Reproducibility of quantitative coronary analysis, Assessment of variability due to frame selection, different observers, and different cinefilmless laboratories.

Authors:  P A Sirnes; Y Myreng; P Mølstad; S Golf
Journal:  Int J Card Imaging       Date:  1996-09

3.  Myocardial performance index for assessment of left ventricular outcome in successfully recanalised anterior myocardial infarction.

Authors:  M Kato; K Dote; S Sasaki; K Goto; H Takemoto; S Habara; D Hasegawa
Journal:  Heart       Date:  2005-05       Impact factor: 5.994

Review 4.  New concepts for interpretation of intracoronary velocity and pressure tracings.

Authors:  C Di Mario; R Gil; M Sunamura; P W Serruys
Journal:  Br Heart J       Date:  1995-11

5.  Automated extraction, labelling and analysis of the coronary vasculature from arteriograms.

Authors:  A C Dumay; J J Gerbrands; J H Reiber
Journal:  Int J Card Imaging       Date:  1994-09

6.  Postmortem validation of the automated coronary analysis (ACA) software package.

Authors:  R J van der Geest; K G Morris; J T Cusma; J H Reiber
Journal:  Int J Card Imaging       Date:  1994-06

7.  Uncomplicated moderate coronary artery dissections after balloon angioplasty: good outcome without stenting.

Authors:  M Albertal; G Van Langenhove; E Regar; I P Kay; D Foley; G Sianos; K Kozuma; T Beijsterveldt; S G Carlier; J A Belardi; E Boersma; J E Sousa; B de Bruyne; P W Serruys
Journal:  Heart       Date:  2001-08       Impact factor: 5.994

8.  Calibration-free coronary artery measurements for interventional device sizing using inverse geometry x-ray fluoroscopy: in vivo validation.

Authors:  Michael T Tomkowiak; Amish N Raval; Michael S Van Lysel; Tobias Funk; Michael A Speidel
Journal:  J Med Imaging (Bellingham)       Date:  2014-10

9.  Mechanical features and in vivo imaging of a polymer stent.

Authors:  W J van der Giessen; C J Slager; E J Gussenhoven; H M van Beusekom; R A Huijts; J C Schuurbiers; R A Wilson; P W Serruys; P D Verdouw
Journal:  Int J Card Imaging       Date:  1993-09
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.