Literature DB >> 15253628

Buffer loading for counteracting metal salt-induced signal suppression in electrospray ionization.

Anthony T Iavarone1, Osita A Udekwu, Evan R Williams.   

Abstract

The decrease in the sensitivity of electrospray ionization mass spectrometry caused by the presence of metal salts, such as sodium chloride, in the sample matrix is well known and is particularly problematic for biological samples. We report here that addition of high levels of ammonium acetate can improve analyte signal in aqueous electrospray solutions and counteracts the signal suppression caused by sodium chloride. A approximately 3-fold improvement in S/N is obtained by adding 8 M ammonium acetate to aqueous solutions of cytochrome c without added sodium chloride. No organic solvents or acids are added into the electrospray solutions. The signal-to-noise ratios of cytochrome c and ubiquitin (10(-)(5) M) ions formed from aqueous solutions containing 2.0 x 10(-)(2) M sodium chloride are improved by factors of approximately 7 and 11, respectively, by adding 7 M ammonium acetate to the solution. We propose that this effect is a result of the precipitation of Na(+) and Cl(-) from solution within the evaporating electrospray droplets prior to the formation of gas-phase protein ions. This method is potentially useful for improving the abundance of protein ions formed from solutions in which the molecules have a nativelike conformation and is particularly advantageous for such solutions that have high levels of sodium.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15253628      PMCID: PMC1343452          DOI: 10.1021/ac049724+

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  28 in total

1.  Reduction in matrix-related signal suppression effects in electrospray ionization mass spectrometry using on-line two-dimensional liquid chromatography.

Authors:  R Pascoe; J P Foley; A I Gusev
Journal:  Anal Chem       Date:  2001-12-15       Impact factor: 6.986

2.  Global analysis of the Deinococcus radiodurans proteome by using accurate mass tags.

Authors:  Mary S Lipton; Ljiljana Pasa-Tolic'; Gordon A Anderson; David J Anderson; Deanna L Auberry; John R Battista; Michael J Daly; Jim Fredrickson; Kim K Hixson; Heather Kostandarithes; Christophe Masselon; Lye Meng Markillie; Ronald J Moore; Margaret F Romine; Yufeng Shen; Eric Stritmatter; Nikola Tolic'; Harold R Udseth; Amudhan Venkateswaran; Kwong-Kwok Wong; Rui Zhao; Richard D Smith
Journal:  Proc Natl Acad Sci U S A       Date:  2002-08-12       Impact factor: 11.205

3.  A highly efficient and automated method of purifying and desalting PCR products for analysis by electrospray ionization mass spectrometry.

Authors:  Yun Jiang; Steven A Hofstadler
Journal:  Anal Biochem       Date:  2003-05-01       Impact factor: 3.365

4.  Effects of charge state and cationizing agent on the electron capture dissociation of a peptide.

Authors:  Anthony T Iavarone; Kolja Paech; Evan R Williams
Journal:  Anal Chem       Date:  2004-04-15       Impact factor: 6.986

5.  Tandem FTMS of Large Biomolecules.

Authors:  E R Williams
Journal:  Anal Chem       Date:  1998-03-01       Impact factor: 6.986

6.  Mechanism of signal suppression by anionic surfactants in capillary electrophoresis-electrospray ionization mass spectrometry.

Authors:  K L Rundlett; D W Armstrong
Journal:  Anal Chem       Date:  1996-10-01       Impact factor: 6.986

7.  Analytical properties of the nanoelectrospray ion source.

Authors:  M Wilm; M Mann
Journal:  Anal Chem       Date:  1996-01-01       Impact factor: 6.986

8.  On-line immunoaffinity extraction-coupled column capillary liquid chromatography/tandem mass spectrometry: trace analysis of LSD analogs and metabolites in human urine.

Authors:  J Cai; J Henion
Journal:  Anal Chem       Date:  1996-01-01       Impact factor: 6.986

9.  Effects of charge state on fragmentation pathways, dynamics, and activation energies of ubiquitin ions measured by blackbody infrared radiative dissociation.

Authors:  R A Jockusch; P D Schnier; W D Price; E F Strittmatter; P A Demirev; E R Williams
Journal:  Anal Chem       Date:  1997-03-15       Impact factor: 6.986

10.  Enhanced sensitivity for peptide mapping with electrospray liquid chromatography-mass spectrometry in the presence of signal suppression due to trifluoroacetic acid-containing mobile phases.

Authors:  A Apffel; S Fischer; G Goldberg; P C Goodley; F E Kuhlmann
Journal:  J Chromatogr A       Date:  1995-09-29       Impact factor: 4.759

View more
  45 in total

1.  The use of chromium(III) to supercharge peptides by protonation at low basicity sites.

Authors:  Changgeng Feng; Juliette J Commodore; Carolyn J Cassady
Journal:  J Am Soc Mass Spectrom       Date:  2014-11-14       Impact factor: 3.109

2.  Electrothermal supercharging of proteins in native electrospray ionization.

Authors:  Harry J Sterling; Catherine A Cassou; Anna C Susa; Evan R Williams
Journal:  Anal Chem       Date:  2012-03-19       Impact factor: 6.986

3.  Reliable determinations of protein-ligand interactions by direct ESI-MS measurements. Are we there yet?

Authors:  Elena N Kitova; Amr El-Hawiet; Paul D Schnier; John S Klassen
Journal:  J Am Soc Mass Spectrom       Date:  2012-01-21       Impact factor: 3.109

4.  Anion effects on sodium ion and acid molecule adduction to protein ions in electrospray ionization mass spectrometry.

Authors:  Tawnya G Flick; Samuel I Merenbloom; Evan R Williams
Journal:  J Am Soc Mass Spectrom       Date:  2011-08-09       Impact factor: 3.109

5.  Effects of select anions from the Hofmeister series on the gas-phase conformations of protein ions measured with traveling-wave ion mobility spectrometry/mass spectrometry.

Authors:  Samuel I Merenbloom; Tawnya G Flick; Michael P Daly; Evan R Williams
Journal:  J Am Soc Mass Spectrom       Date:  2011-09-13       Impact factor: 3.109

6.  Direct correlation of the crystal structure of proteins with the maximum positive and negative charge states of gaseous protein ions produced by electrospray ionization.

Authors:  Halan Prakash; Shyamalava Mazumdar
Journal:  J Am Soc Mass Spectrom       Date:  2005-09       Impact factor: 3.109

7.  Addressing a Common Misconception: Ammonium Acetate as Neutral pH "Buffer" for Native Electrospray Mass Spectrometry.

Authors:  Lars Konermann
Journal:  J Am Soc Mass Spectrom       Date:  2017-07-14       Impact factor: 3.109

8.  Analysis of protein mixtures by electrospray mass spectrometry: effects of conformation and desolvation behavior on the signal intensities of hemoglobin subunits.

Authors:  Mark C Kuprowski; Brian L Boys; Lars Konermann
Journal:  J Am Soc Mass Spectrom       Date:  2007-04-15       Impact factor: 3.109

9.  Enhancing the response of alkyl methylphosphonic acids in negative electrospray ionization liquid chromatography tandem mass spectrometry by post-column addition of organic solvents.

Authors:  Douglas B Mawhinney; Rayman D Stanelle; Elizabeth I Hamelin; Robert J Kobelski
Journal:  J Am Soc Mass Spectrom       Date:  2007-07-29       Impact factor: 3.109

10.  Ammonium Bicarbonate Addition Improves the Detection of Proteins by Desorption Electrospray Ionization Mass Spectrometry.

Authors:  Elahe Honarvar; Andre R Venter
Journal:  J Am Soc Mass Spectrom       Date:  2017-03-17       Impact factor: 3.109

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.