Literature DB >> 8779437

On-line immunoaffinity extraction-coupled column capillary liquid chromatography/tandem mass spectrometry: trace analysis of LSD analogs and metabolites in human urine.

J Cai1, J Henion.   

Abstract

An on-line immunoaffinity extraction-coupled column capillary liquid chromatography/tandem mass spectrometry (IAE/LC/LC/MS/MS) method is described. The system involves three columns, a 2.1-mm-i.d. protein G immunoaffinity column with noncovalently immobilized antibody specific to the analytes of interest, a packed capillary trapping column, and a packed capillary analytical column. With use of a short packed capillary trapping column, the protein G column could be operated at flow rates of 2.5-4 mL/min while the packed capillary analytical column was maintained at a flow rate of 3.5 microL/min. Human urine diluted 1:1 with phosphate-buffered saline was pumped directly onto the immunoaffinity column without pretreatment and was analyzed by electrospray mass spectrometry following the column switching process. Sample handling and transfer procedures were eliminated. The system was optimized and evaluated for the determination of LSD, its analogs, and metabolites in spiked human urine at low part-per-trillion (ppt) levels using mass spectrometric detection. LSD-positive human urine specimens from LSD users were also analyzed. Concentrations as low as 2.5 ppt of LSD and several of its analogs were detected in spiked human urine using IAE/LC/LC/MS/MS/. This is 20-fold below our previous limit of detection using solid phase extraction and LC/MS/MS.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8779437     DOI: 10.1021/ac950763i

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  6 in total

1.  Mass spectrometry and immobilized enzymes for the screening of inhibitor libraries.

Authors:  M T Cancilla; M D Leavell; J Chow; J A Leary
Journal:  Proc Natl Acad Sci U S A       Date:  2000-10-24       Impact factor: 11.205

2.  Mass spectrometry and non-covalent protein-ligand complexes: confirmation of binding sites and changes in tertiary structure.

Authors:  Sharon J Shields; Olayinka Oyeyemi; Felice C Lightstone; Rod Balhorn
Journal:  J Am Soc Mass Spectrom       Date:  2003-05       Impact factor: 3.109

3.  Buffer loading for counteracting metal salt-induced signal suppression in electrospray ionization.

Authors:  Anthony T Iavarone; Osita A Udekwu; Evan R Williams
Journal:  Anal Chem       Date:  2004-07-15       Impact factor: 6.986

4.  Multidimensional chromatography coupled with mass spectrometry for target-based screening.

Authors:  Y F Hsieh; N Gordon; F Regnier; N Afeyan; S A Martin; G J Vella
Journal:  Mol Divers       Date:  1997       Impact factor: 2.943

5.  Quantification of 1α,25-dihydroxy vitamin D by immunoextraction and liquid chromatography-tandem mass spectrometry.

Authors:  Frederick G Strathmann; Thomas J Laha; Andrew N Hoofnagle
Journal:  Clin Chem       Date:  2011-07-18       Impact factor: 8.327

6.  LC-ESI-MS/MS on an ion trap for the determination of LSD, iso-LSD, nor-LSD and 2-oxo-3-hydroxy-LSD in blood, urine and vitreous humor.

Authors:  Donata Favretto; Giampietro Frison; Sergio Maietti; Santo Davide Ferrara
Journal:  Int J Legal Med       Date:  2006-02-23       Impact factor: 2.791