Literature DB >> 15249999

[Cup placement in hip replacement surgery -- A comparison of free-hand and computer assisted cup placement in total hip arthroplasty -- a multi-center study].

G Saxler1, A Marx, D Vandevelde, U Langlotz, M Tannast, M Wiese, U Michaelis, G Kemper, P A Grützner, R Steffen, M von Knoch, T Holland-Letz, K Bernsmann.   

Abstract

AIM: The purpose of the current study was to determine the accuracy of free hand and computer-assisted (CAS) cup placement.
MATERIAL AND METHODS: Between June 1985 and August 2001, 105 free-hand and from March to November 1999 80 total hip arthroplasties under computer assistance were implanted in the above mentioned centers. To determine the accuracy of the cups, the inclination and anteversion angles were measured. In all cases the cup position was measured with a CT-investigation of the pelvis. Statistical analysis was performed with the F-test.
RESULTS: With regard to the inclination and anteversion angles the variability of the cup position was significantly higher in the group of free hand implanted cups. In the CAS group we could not find any "extreme" positions.
CONCLUSION: Using computer-assisted surgery a significantly higher reproducible cup position can be obtained. Long time survey may present a lowering of the rate of early and late complications caused by better prostheses alignment in the follow up.

Entities:  

Mesh:

Year:  2004        PMID: 15249999     DOI: 10.1055/s-2004-822696

Source DB:  PubMed          Journal:  Z Orthop Ihre Grenzgeb        ISSN: 0044-3220


  7 in total

1.  Improving cup positioning using a mechanical navigation instrument.

Authors:  Simon D Steppacher; Jens H Kowal; Stephen Barry Murphy
Journal:  Clin Orthop Relat Res       Date:  2011-02       Impact factor: 4.176

2.  Accuracy of acetabular cup placement in computer-assisted, minimally-invasive THR in a lateral decubitus position.

Authors:  Ernst Sendtner; Tibor Schuster; Michael Wörner; Thomas Kalteis; Joachim Grifka; Tobias Renkawitz
Journal:  Int Orthop       Date:  2010-05-21       Impact factor: 3.075

3.  Estimation of pelvic tilt on anteroposterior X-rays--a comparison of six parameters.

Authors:  M Tannast; S B Murphy; F Langlotz; S E Anderson; K A Siebenrock
Journal:  Skeletal Radiol       Date:  2005-12-20       Impact factor: 2.199

Review 4.  Evidence-based computer-navigated total hip arthroplasty: an updated analysis of randomized controlled trials.

Authors:  Yu-Lin Li; Jun Jia; Qiang Wu; Guang-Zhi Ning; Qiu-Li Wu; Shi-Qing Feng
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-04-16

5.  Pelvic tilt is minimally changed by total hip arthroplasty.

Authors:  William S Murphy; Greg Klingenstein; Stephen B Murphy; Guoyan Zheng
Journal:  Clin Orthop Relat Res       Date:  2013-02       Impact factor: 4.176

6.  Early postoperative clinical recovery of robotic arm-assisted vs. image-based navigated Total hip Arthroplasty.

Authors:  Nao Shibanuma; Kazunari Ishida; Tomoyuki Matsumoto; Koji Takayama; Yutaro Sanada; Masahiro Kurosaka; Ryosuke Kuroda; Shinya Hayashi
Journal:  BMC Musculoskelet Disord       Date:  2021-03-29       Impact factor: 2.362

Review 7.  Navigated cup implantation in hip arthroplasty.

Authors:  Johannes Beckmann; Dirk Stengel; Markus Tingart; Jürgen Götz; Joachim Grifka; Christian Lüring
Journal:  Acta Orthop       Date:  2009-10       Impact factor: 3.717

  7 in total