Literature DB >> 15237815

1-3 piezoelectric composite transducers for swept-frequency calibration of hydrophones from 100 kHz to 2 MHz.

Gerald R Harris1, Paul M Gammell.   

Abstract

Rapid calibration of hydrophones used in biomedical ultrasound is possible with swept frequency techniques such as time delay spectrometry. However, calibrations below 2 MHz largely have been neglected because of insufficient transmitting transducer bandwidth, even though important medical applications operate in this range. To address this deficiency, several transmitting transducer designs were developed and tested, and two 1-3 piezoelectric composite designs were found to have the requisite bandwidth and uniformity of response. In one the element has a plane front face and spherically concave back face (plano-concave), and in the second both faces are concave, but with different radii of curvature (biconcave). The nonuniform thickness disperses the thickness resonance, and the composite structure suppresses radial-mode resonances. Also, the composite's lower acoustic impedance provides a more efficient match to water. The piezoelectric composite transducers were found to have transmitting pressure sensitivities superior to ceramic single-element and segmented designs having similar dimensions, and their responses were significantly more uniform (< 25 dB variation from 0.1-2 MHz, with < 1 dB fine structure variation), likely due to decreased contributions from radial modes.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15237815     DOI: 10.1121/1.1707090

Source DB:  PubMed          Journal:  J Acoust Soc Am        ISSN: 0001-4966            Impact factor:   1.840


  3 in total

1.  Improved measurement of acoustic output using complex deconvolution of hydrophone sensitivity.

Authors:  Keith A Wear; Paul M Gammell; Subha Maruvada; Yunbo Liu; Gerald R Harris
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2014-01       Impact factor: 2.725

2.  Pressure Pulse Distortion by Needle and Fiber-Optic Hydrophones due to Nonuniform Sensitivity.

Authors:  Keith A Wear; Yunbo Liu; Gerald R Harris
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-02       Impact factor: 2.725

3.  Broadband characterization of plastic and high intensity therapeutic ultrasound phantoms using time delay spectrometry-With validation using Kramers-Kronig relations.

Authors:  Subha Maruvada; Yunbo Liu; Paul Gammell; Keith Wear
Journal:  J Acoust Soc Am       Date:  2018-06       Impact factor: 1.840

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.