Literature DB >> 15235333

Comparison of activity monitors to estimate energy cost of treadmill exercise.

George A King1, Nancy Torres, Charlie Potter, Toby J Brooks, Karen J Coleman.   

Abstract

PURPOSE: To evaluate the validity of five physical activity monitors available for research: the CSA, the TriTrac-R3D, the RT3, the SenseWear Armband, and the BioTrainer-Pro.
METHODS: A total of 10 healthy men and 11 healthy women performed 10 min of treadmill walking at 54, 80, and 107 mxmin and treadmill running at 134, 161, 188, and 214 mxmin. The CSA, TriTrac-R3D, RT3, and BioTrainer-Pro accelerometers were placed side by side bilaterally at the waist in the axillary position, and the SenseWear Armband monitors were placed bilaterally on the posterior portion of each arm in the mid-humeral position. Simultaneous measurements of body motion and indirect calorimetry were continuously recorded during all exercise. Data were analyzed with repeated measures ANOVA and pairwise Bonferroni-adjusted estimated marginal means.
RESULTS: : There was no significant difference in the mean energy expenditure (EE) recorded bilaterally by any of the monitors (P < 0.05) at any treadmill speed. The SenseWear Armband, the TriTrac-R3D, and the RT3 had significant increases in mean EE across all walking and running speeds (P < 0.05). Below 161 mxmin, the mean EE recorded by the BioTrainer-Pro and the CSA increased significantly (P < 0.001); however, there was no significant difference (P > 0.10) in mean EE recorded by either monitor for speeds above 161 mxmin. In general, all monitors overestimated EE at most treadmill speeds when compared with indirect calorimetry (P < 0.001), except for the CSA which underestimated EE at the lowest and highest speeds.
CONCLUSION: The CSA was the best estimate of total EE at walking and jogging speeds, the TriTrac-R3D was the best estimate of total EE at running speeds, and the SenseWear Armband was the best estimate of total EE at most speeds.

Entities:  

Mesh:

Year:  2004        PMID: 15235333     DOI: 10.1249/01.mss.0000132379.09364.f8

Source DB:  PubMed          Journal:  Med Sci Sports Exerc        ISSN: 0195-9131            Impact factor:   5.411


  53 in total

Review 1.  Measurement of human energy expenditure, with particular reference to field studies: an historical perspective.

Authors:  Roy J Shephard; Yukitoshi Aoyagi
Journal:  Eur J Appl Physiol       Date:  2011-12-11       Impact factor: 3.078

2.  Energy intake and expenditure during sedentary screen time and motion-controlled video gaming.

Authors:  Elizabeth J Lyons; Deborah F Tate; Dianne S Ward; Xiaoshan Wang
Journal:  Am J Clin Nutr       Date:  2012-07-03       Impact factor: 7.045

3.  Estimates of ventilation from measurements of rib cage and abdominal distances: a portable device.

Authors:  S Gastinger; H Sefati; G Nicolas; A Sorel; A Gratas-Delamarche; J Prioux
Journal:  Eur J Appl Physiol       Date:  2010-04-09       Impact factor: 3.078

4.  Validation of the SenseWear Armband at high intensity exercise.

Authors:  Clemens Drenowatz; Joey C Eisenmann
Journal:  Eur J Appl Physiol       Date:  2010-10-24       Impact factor: 3.078

5.  Choice of interactive dance and bicycle games in overweight and nonoverweight youth.

Authors:  Leonard H Epstein; Meghan D Beecher; Jennifer L Graf; James N Roemmich
Journal:  Ann Behav Med       Date:  2007-04

6.  Activity monitoring and energy expenditure in COPD patients: a validation study.

Authors:  Sanjay A Patel; Roberto P Benzo; William A Slivka; Frank C Sciurba
Journal:  COPD       Date:  2007-06       Impact factor: 2.409

7.  A comparison between ventilation and heart rate as indicator of oxygen uptake during different intensities of exercise.

Authors:  Steven Gastinger; Anthony Sorel; Guillaume Nicolas; Arlette Gratas-Delamarche; Jacques Prioux
Journal:  J Sports Sci Med       Date:  2010-03-01       Impact factor: 2.988

8.  Using three objective criteria to examine pedometer guidelines for free-living individuals.

Authors:  Duncan James Macfarlane; Dionise Chan; K L Chan; Edmond Y K Ho; Cherry C Y Lee
Journal:  Eur J Appl Physiol       Date:  2008-06-17       Impact factor: 3.078

9.  Validation of the Sensewear Armband during recreational in-line skating.

Authors:  Maroje Soric; Pavle Mikulic; Marjeta Misigoj-Durakovic; Lana Ruzic; Goran Markovic
Journal:  Eur J Appl Physiol       Date:  2011-06-17       Impact factor: 3.078

10.  A new method to estimate energy expenditure from abdominal and rib cage distances.

Authors:  S Gastinger; H Sefati; G Nicolas; A Sorel; A Gratas-Delamarche; J Prioux
Journal:  Eur J Appl Physiol       Date:  2011-03-18       Impact factor: 3.078

View more