Literature DB >> 24149394

A comparison between ventilation and heart rate as indicator of oxygen uptake during different intensities of exercise.

Steven Gastinger1, Anthony Sorel, Guillaume Nicolas, Arlette Gratas-Delamarche, Jacques Prioux.   

Abstract

The aim of this study is to compare the relation between ventilation (VE) and oxygen uptake (VO2) [VO2=ƒ(VE)] and between heart rate (HR) and VO2 [VO2=ƒ(HR)]. Each one of the subjects performed three types of activities of different intensities (walking without load, walking with load and intermittent work). VO2, VE, and HR were measured continuously by using indirect calorimetry and an electrocardiogram. Linear regressions and coefficients of determination (r(2)) were calculated to compare the relation VO2 =ƒ(VE) and VO2 =ƒ(HR) for two different regroupings: by session duration (r(2) session) and by subject (r(2) subject). Results showed that r(2) session of the relation VO2 =ƒ(VE) were significantly higher than those of the relation VO2 =ƒ(HR) for steady state activities (walking with or without load during 3 or 6 min, p < 0.01) and for activities without oxygen consumption steady state (walking with or without load during 1 min, p < 0.01 and intermittent work, p < 0.05). VE is more strongly correlated with VO2 than with HR. This is a very promising approach to develop a new method to estimate energy expenditure. Key pointsVentilation is more strongly correlated with oxygen uptake than heart rate during physical activities of different intensities.This study shows the interest to looking for ventilation to estimate energy expenditure.This study is a promising approach to develop a new method to estimate energy expenditureAn interesting perspective could be to develop a light and portable device to measure ventilation based on the coupling of four magnetometers.

Entities:  

Keywords:  Physical activities; light to moderate intensities; non-steady state activities.; steady state activities

Year:  2010        PMID: 24149394      PMCID: PMC3737974     

Source DB:  PubMed          Journal:  J Sports Sci Med        ISSN: 1303-2968            Impact factor:   2.988


  36 in total

1.  Tidal volume and respiratory timing derived from a portable ventilation monitor.

Authors:  F Dennis McCool; John Wang; Kristi L Ebi
Journal:  Chest       Date:  2002-08       Impact factor: 9.410

2.  Estimating relative physical workload using heart rate monitoring: a validation by whole-body indirect calorimetry.

Authors:  Martin Garet; Gil Boudet; Christophe Montaurier; Michel Vermorel; Jean Coudert; Alain Chamoux
Journal:  Eur J Appl Physiol       Date:  2004-12-18       Impact factor: 3.078

3.  A simple method of measuring total daily energy expenditure and physical activity level from the heart rate in adult men.

Authors:  A V Kurpad; R Raj; K N Maruthy; M Vaz
Journal:  Eur J Clin Nutr       Date:  2006-01       Impact factor: 4.016

Review 4.  Comparison of cardioprotective benefits of vigorous versus moderate intensity aerobic exercise.

Authors:  David P Swain; Barry A Franklin
Journal:  Am J Cardiol       Date:  2005-11-16       Impact factor: 2.778

5.  Maximal oxygen uptake in athletes.

Authors:  B Saltin; P O Astrand
Journal:  J Appl Physiol       Date:  1967-09       Impact factor: 3.531

6.  Validity of four motion sensors in measuring moderate intensity physical activity.

Authors:  D R Bassett; B E Ainsworth; A M Swartz; S J Strath; W L O'Brien; G A King
Journal:  Med Sci Sports Exerc       Date:  2000-09       Impact factor: 5.411

7.  Neural control of cardiovascular responses and of ventilation during dynamic exercise in man.

Authors:  S Strange; N H Secher; J A Pawelczyk; J Karpakka; N J Christensen; J H Mitchell; B Saltin
Journal:  J Physiol       Date:  1993-10       Impact factor: 5.182

8.  Comparison of PAEE from combined and separate heart rate and movement models in children.

Authors:  Kirsten Corder; Søren Brage; Nicholas J Wareham; Ulf Ekelund
Journal:  Med Sci Sports Exerc       Date:  2005-10       Impact factor: 5.411

9.  Energy expenditure from minute-by-minute heart-rate recording: comparison with indirect calorimetry.

Authors:  G B Spurr; A M Prentice; P R Murgatroyd; G R Goldberg; J C Reina; N T Christman
Journal:  Am J Clin Nutr       Date:  1988-09       Impact factor: 7.045

Review 10.  Accelerometers and pedometers: methodology and clinical application.

Authors:  Kirsten Corder; Søren Brage; Ulf Ekelund
Journal:  Curr Opin Clin Nutr Metab Care       Date:  2007-09       Impact factor: 4.294

View more
  10 in total

1.  The facemask produces higher peak minute ventilation and respiratory rate measurements compared to the mouthpiece.

Authors:  Kirsten Bell; Megan Bedbrook; Tri-Tue Nguyen; Marina Mourtzakis
Journal:  J Sports Sci Med       Date:  2012-09-01       Impact factor: 2.988

2.  A new method to estimate energy expenditure from abdominal and rib cage distances.

Authors:  S Gastinger; H Sefati; G Nicolas; A Sorel; A Gratas-Delamarche; J Prioux
Journal:  Eur J Appl Physiol       Date:  2011-03-18       Impact factor: 3.078

3.  Estimation of respiratory volume from thoracoabdominal breathing distances: comparison of two models of machine learning.

Authors:  Rémy Dumond; Steven Gastinger; Hala Abdul Rahman; Alexis Le Faucheur; Patrice Quinton; Haitao Kang; Jacques Prioux
Journal:  Eur J Appl Physiol       Date:  2017-06-13       Impact factor: 3.078

4.  Respiratory dysfunction in two rodent models of chronic epilepsy and acute seizures and its link with the brainstem serotonin system.

Authors:  Hayet Kouchi; Michaël Ogier; Gabriel Dieuset; Anne Morales; Béatrice Georges; Jean-Louis Rouanet; Benoît Martin; Philippe Ryvlin; Sylvain Rheims; Laurent Bezin
Journal:  Sci Rep       Date:  2022-06-17       Impact factor: 4.996

5.  Measured by the oxygen uptake in the field, the work of refuse collectors is particularly hard work: Are the limit values for physical endurance workload too low?

Authors:  Alexandra M Preisser; Linfei Zhou; Marcial Velasco Garrido; Volker Harth
Journal:  Int Arch Occup Environ Health       Date:  2015-06-19       Impact factor: 3.015

6.  Enhancing instantaneous oxygen uptake estimation by non-linear model using cardio-pulmonary physiological and motion signals.

Authors:  Zhao Wang; Qiang Zhang; Ke Lan; Zhicheng Yang; Xiaolin Gao; Anshuo Wu; Yi Xin; Zhengbo Zhang
Journal:  Front Physiol       Date:  2022-08-25       Impact factor: 4.755

7.  Estimation of Respiratory Frequency in Women and Men by Kubios HRV Software Using the Polar H10 or Movesense Medical ECG Sensor during an Exercise Ramp.

Authors:  Bruce Rogers; Marcelle Schaffarczyk; Thomas Gronwald
Journal:  Sensors (Basel)       Date:  2022-09-21       Impact factor: 3.847

8.  Comparison of physiological and perceptual responses between continuous and intermittent cycling.

Authors:  Roxana M Brasil; Ana C Barreto; Leandro Nogueira; Edil Santos; Jefferson S Novaes; Victor M Reis
Journal:  J Hum Kinet       Date:  2011-10-04       Impact factor: 2.193

9.  Energy expenditure estimation from respiration variables.

Authors:  Rahel Gilgen-Ammann; Marcel Koller; Céline Huber; Riikka Ahola; Topi Korhonen; Thomas Wyss
Journal:  Sci Rep       Date:  2017-11-22       Impact factor: 4.379

10.  Fusion of Heart Rate, Respiration and Motion Measurements from a Wearable Sensor System to Enhance Energy Expenditure Estimation.

Authors:  Ke Lu; Liyun Yang; Fernando Seoane; Farhad Abtahi; Mikael Forsman; Kaj Lindecrantz
Journal:  Sensors (Basel)       Date:  2018-09-14       Impact factor: 3.576

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.