Literature DB >> 15230872

Imaging enzyme activity with polarization-sensitive confocal fluorescence microscopy.

Chad E Bigelow1, Harshad D Vishwasrao, John G Frelinger, Thomas H Foster.   

Abstract

We describe a technique for imaging enzyme activity through steady-state fluorescence anisotropy measurements on a per-pixel basis with a confocal microscope. With this method, enzyme activity is reported by changes in the fluorescence anisotropy of a fluorescently labelled substrate. Enzymatic cleavage of the substrate yields smaller labelled fragments that tumble more readily than the intact substrate and therefore yield a lower anisotropy. Anisotropy is recovered to an accuracy of 7% or better on and off the optical axis to depths of 210 microm using objective numerical apertures as high as 0.75. Enzyme imaging experiments were performed with Bodipy-FL-labelled bovine serum albumin (BSA) attached to sepharose beads as a substrate for trypsin and proteinase K. Anisotropy images acquired up to 1 h after enzyme addition revealed more rapid digestion of BSA with proteinase K than with trypsin, but in both cases anisotropy decreased by at least five-fold. Fluorescence lifetime and time-resolved anisotropy decay measurements were made on the construct in fluid solution to reveal the effects of enzyme activity. The Bodipy-FL lifetime increased from 1.34 ns for the construct without enzyme to 5.98 ns after 1 h in the presence of proteinase K. Anisotropy decays yielded average rotational correlation times of 1.13 ns before enzymatic action and 0.27 ns after enzymatic action, consistent with the presence of smaller Bodipy-containing protein fragments. These results suggest wide applicability of the technique in biological systems when used in conjunction with appropriately designed constructs.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15230872     DOI: 10.1111/j.0022-2720.2004.01357.x

Source DB:  PubMed          Journal:  J Microsc        ISSN: 0022-2720            Impact factor:   1.758


  4 in total

Review 1.  Imaging enzymes at work: metabolic mapping by enzyme histochemistry.

Authors:  Cornelis J F Van Noorden
Journal:  J Histochem Cytochem       Date:  2010-02-01       Impact factor: 2.479

2.  Measurement of drug-target engagement in live cells by two-photon fluorescence anisotropy imaging.

Authors:  Claudio Vinegoni; Paolo Fumene Feruglio; Christian Brand; Sungon Lee; Antoinette E Nibbs; Shawn Stapleton; Sunil Shah; Ignacy Gryczynski; Thomas Reiner; Ralph Mazitschek; Ralph Weissleder
Journal:  Nat Protoc       Date:  2017-06-29       Impact factor: 13.491

Review 3.  Fluorescence anisotropy imaging in drug discovery.

Authors:  Claudio Vinegoni; Paolo Fumene Feruglio; Ignacy Gryczynski; Ralph Mazitschek; Ralph Weissleder
Journal:  Adv Drug Deliv Rev       Date:  2018-02-02       Impact factor: 15.470

4.  Increased signals from short-wavelength-excited fluorescent molecules using sub-Ti:Sapphire wavelengths.

Authors:  G Norris; R Amor; J Dempster; W B Amos; G McConnell
Journal:  J Microsc       Date:  2012-11       Impact factor: 1.758

  4 in total