Literature DB >> 29410158

Fluorescence anisotropy imaging in drug discovery.

Claudio Vinegoni1, Paolo Fumene Feruglio2, Ignacy Gryczynski3, Ralph Mazitschek4, Ralph Weissleder4.   

Abstract

Non-invasive measurement of drug-target engagement can provide critical insights in the molecular pharmacology of small molecule drugs. Fluorescence polarization/fluorescence anisotropy measurements are commonly employed in protein/cell screening assays. However, the expansion of such measurements to the in vivo setting has proven difficult until recently. With the advent of high-resolution fluorescence anisotropy microscopy it is now possible to perform kinetic measurements of intracellular drug distribution and target engagement in commonly used mouse models. In this review we discuss the background, current advances and future perspectives in intravital fluorescence anisotropy measurements to derive pharmacokinetic and pharmacodynamic measurements in single cells and whole organs.
Copyright © 2018 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Drug-target engagement; Fluorescence anisotropy imaging; Fluorescence polarization, fluorescence anisotropy; Fluorescently labeled drugs; Intravital imaging; Single-cell pharmacodynamics; Two photon microscopy

Year:  2018        PMID: 29410158      PMCID: PMC6072632          DOI: 10.1016/j.addr.2018.01.019

Source DB:  PubMed          Journal:  Adv Drug Deliv Rev        ISSN: 0169-409X            Impact factor:   15.470


  315 in total

Review 1.  FRET imaging.

Authors:  Elizabeth A Jares-Erijman; Thomas M Jovin
Journal:  Nat Biotechnol       Date:  2003-11       Impact factor: 54.908

Review 2.  Fluorescence lifetime measurements and biological imaging.

Authors:  Mikhail Y Berezin; Samuel Achilefu
Journal:  Chem Rev       Date:  2010-05-12       Impact factor: 60.622

3.  Fluorescence detection of the anticancer drug topotecan in plasma and whole blood by two-photon excitation.

Authors:  T G Burke; H Malak; I Gryczynski; Z Mi; J R Lakowicz
Journal:  Anal Biochem       Date:  1996-11-15       Impact factor: 3.365

4.  Analog single-photon counter for high-speed scanning microscopy.

Authors:  Sucbei Moon; Dug Young Kim
Journal:  Opt Express       Date:  2008-09-01       Impact factor: 3.894

5.  Spatially localized ballistic two-photon excitation in scattering media.

Authors:  H Szmacinski; I Gryczynski; J R Lakowicz
Journal:  Biospectroscopy       Date:  1998

6.  Dissection of molecular assembly dynamics by tracking orientation and position of single molecules in live cells.

Authors:  Shalin B Mehta; Molly McQuilken; Patrick J La Riviere; Patricia Occhipinti; Amitabh Verma; Rudolf Oldenbourg; Amy S Gladfelter; Tomomi Tani
Journal:  Proc Natl Acad Sci U S A       Date:  2016-09-27       Impact factor: 11.205

7.  Design and application of a confocal microscope for spectrally resolved anisotropy imaging.

Authors:  Alessandro Esposito; Arjen N Bader; Simon C Schlachter; Dave J van den Heuvel; Gabriele S Kaminski Schierle; Ashok R Venkitaraman; Clemens F Kaminski; Hans C Gerritsen
Journal:  Opt Express       Date:  2011-01-31       Impact factor: 3.894

8.  PARP1 expression in pediatric central nervous system tumors.

Authors:  Valerie N Barton; Andrew M Donson; B K Kleinschmidt-DeMasters; Lia Gore; Arthur K Liu; Nicholas K Foreman
Journal:  Pediatr Blood Cancer       Date:  2009-12-15       Impact factor: 3.167

9.  Associated Anisotropy Decays of Ethidium Bromide Interacting with DNA.

Authors:  Rahul Chib; Sangram Raut; Sarika Sabnis; Preeti Singhal; Zygmunt Gryczynski; Ignacy Gryczynski
Journal:  Methods Appl Fluoresc       Date:  2014-01-23       Impact factor: 3.009

10.  Super-resolution dipole orientation mapping via polarization demodulation.

Authors:  Karl Zhanghao; Long Chen; Xu-San Yang; Miao-Yan Wang; Zhen-Li Jing; Hong-Bin Han; Michael Q Zhang; Dayong Jin; Jun-Tao Gao; Peng Xi
Journal:  Light Sci Appl       Date:  2016-10-21       Impact factor: 17.782

View more
  11 in total

1.  Two-Photon Fluorescence Imaging.

Authors:  Fan Feng; Heng Mao; Aimin Wang; Liangyi Chen
Journal:  Adv Exp Med Biol       Date:  2021       Impact factor: 2.622

Review 2.  Near-Infrared-II Molecular Dyes for Cancer Imaging and Surgery.

Authors:  Shoujun Zhu; Rui Tian; Alexander L Antaris; Xiaoyuan Chen; Hongjie Dai
Journal:  Adv Mater       Date:  2019-04-26       Impact factor: 30.849

3.  High dynamic range fluorescence imaging.

Authors:  Claudio Vinegoni; Paolo Fumene Feruglio; Ralph Weissleder
Journal:  IEEE J Sel Top Quantum Electron       Date:  2018-11-19       Impact factor: 4.544

4.  Bright and stable luminescent probes for target engagement profiling in live cells.

Authors:  N Connor Payne; Alena S Kalyakina; Kritika Singh; Mark A Tye; Ralph Mazitschek
Journal:  Nat Chem Biol       Date:  2021-10-21       Impact factor: 15.040

Review 5.  Development of Integrated Systems for On-Site Infection Detection.

Authors:  Chang Yeol Lee; Ismail Degani; Jiyong Cheong; Ralph Weissleder; Jae-Hyun Lee; Jinwoo Cheon; Hakho Lee
Journal:  Acc Chem Res       Date:  2021-10-22       Impact factor: 24.466

6.  Multidimensional Fluorescence Microscopy for Simultaneous Functional and Structural Imaging.

Authors:  Klaus Suhling
Journal:  Biophys J       Date:  2019-04-22       Impact factor: 4.033

7.  Targeted fluorescence lifetime probes reveal responsive organelle viscosity and membrane fluidity.

Authors:  Ida Emilie Steinmark; Arjuna L James; Pei-Hua Chung; Penny E Morton; Maddy Parsons; Cécile A Dreiss; Christian D Lorenz; Gokhan Yahioglu; Klaus Suhling
Journal:  PLoS One       Date:  2019-02-14       Impact factor: 3.240

Review 8.  Improving nanotherapy delivery and action through image-guided systems pharmacology.

Authors:  Thomas S C Ng; Michelle A Garlin; Ralph Weissleder; Miles A Miller
Journal:  Theranostics       Date:  2020-01-01       Impact factor: 11.556

9.  A New Spectral Shift-Based Method to Characterize Molecular Interactions.

Authors:  Andreas Langer; Tanja Bartoschik; Ondrej Cehlar; Stefan Duhr; Philipp Baaske; Werner Streicher
Journal:  Assay Drug Dev Technol       Date:  2022-02-15       Impact factor: 1.738

10.  Fluorescence Anisotropy Sensor Comprising a Dual Hollow-Core Antiresonant Fiber Polarization Beam Splitter.

Authors:  Hanna Izabela Stawska; Maciej Andrzej Popenda
Journal:  Sensors (Basel)       Date:  2020-06-11       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.