Literature DB >> 15227647

The reproducibility of urodynamic findings in healthy female volunteers: results of repeated studies in the same setting and after short-term follow-up.

Amit Gupta1, Gina Defreitas, Gary E Lemack.   

Abstract

AIM: To assess the immediate (same testing period) and short-term (within 6 months) repeatability of urodynamic (UD) testing in asymptomatic healthy female volunteers.
MATERIALS AND METHODS: Twenty asymptomatic women with a mean age of 41.8 years (30-55) agreed to undergo a UD assessment which consisted of noninvasive uroflowmetry, post-void residual (PVR) measurement, medium-fill cystometry, and pressure flow study with perineal surface electromyographic (EMG) electrodes. The UDS evaluation was repeated immediately without removing the catheters (a two-fill and void study). Sixteen women returned for an identical UD assessment 1-5 months later. Immediate and short-term repeatability of UD parameters was assessed by calculating the coefficient of repeatability (COR).
RESULTS: The repeatability of certain parameters of immediate UD testing could not be calculated since there was an apparent influence of the first test on the second (i.e., an apparent accommodation noted in bladder filling volumes). Other immediate UD values (maximum flow, detrusor pressure at maximum flow, voided volume) had high COR values, as did all UD values on short-term testing, indicating relatively poor repeatability. Picking the 'best' pressure flow value (highest flow rate with accompanying detrusor pressure) did not consistently improve the COR values.
CONCLUSIONS: The lack of repeatability of UD studies likely stems from a combination of the true physiological fluctuations in bladder function and the inherent relative insensitivity of our instruments in conducting these testing. Knowledge of the limitations of current technology is essential in allowing us to better utilize these studies in evaluating our patients and further improving diagnostic strategies. Copyright 2004 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2004        PMID: 15227647     DOI: 10.1002/nau.20039

Source DB:  PubMed          Journal:  Neurourol Urodyn        ISSN: 0733-2467            Impact factor:   2.696


  14 in total

1.  Implantable wireless battery recharging system for bladder pressure chronic monitoring.

Authors:  Darrin J Young; Peng Cong; Michael A Suster; Margot Damaser
Journal:  Lab Chip       Date:  2015-11-21       Impact factor: 6.799

2.  Wireless, Ultra-Low-Power Implantable Sensor for Chronic Bladder Pressure Monitoring.

Authors:  Steve J A Majerus; Steven L Garverick; Michael A Suster; Paul C Fletter; Margot S Damaser
Journal:  ACM J Emerg Technol Comput Syst       Date:  2012-06-01       Impact factor: 1.420

3.  Urodynamics and stress urinary incontinence: the dark side of a gold standard.

Authors:  Paulo Palma; Viviane Herrmann
Journal:  Int Urogynecol J Pelvic Floor Dysfunct       Date:  2007-07-27

4.  A pilot study to measure dynamic elasticity of the bladder during urodynamics.

Authors:  Andrew F Colhoun; Adam P Klausner; Anna S Nagle; Ashley W Carroll; Robert W Barbee; Paul H Ratz; John E Speich
Journal:  Neurourol Urodyn       Date:  2016-05-31       Impact factor: 2.696

5.  Validation of a real-time bladder sensation meter during oral hydration in healthy adults: Repeatability and effects of fill rate and ultrasound probe pressure.

Authors:  Derek Sheen; Hiren Kolli; Anna S Nagle; Zachary Cullingsworth; Naomi N Vinod; Hameeda A Naimi; Stefan G De Wachter; Suzanne E Mazzeo; Lynn Stothers; John E Speich; Adam P Klausner
Journal:  Low Urin Tract Symptoms       Date:  2019-07-12       Impact factor: 1.592

6.  Is submucosal bladder pressure monitoring feasible?

Authors:  Anisha S Basu; Steve Majerus; Elizabeth Ferry; Iryna Makovey; Hui Zhu; Margot S Damaser
Journal:  Proc Inst Mech Eng H       Date:  2018-01-29       Impact factor: 1.617

Review 7.  Current trends in the evaluation and management of female urinary incontinence.

Authors:  Phillip P Smith; Rebecca J McCrery; Rodney A Appell
Journal:  CMAJ       Date:  2006-11-07       Impact factor: 8.262

8.  Development of an Implantable Wireless and Batteryless Bladder Pressure Monitor System for Lower Urinary Tract Dysfunction.

Authors:  Yihua Zhong; Bolin Qian; Yaguang Zhu; Zhaohui Ren; Junming Deng; Jinghua Liu; Qianrui Bai; Xu Zhang
Journal:  IEEE J Transl Eng Health Med       Date:  2019-10-14       Impact factor: 3.316

9.  Non-invasive characterization of real-time bladder sensation using accelerated hydration and a novel sensation meter: An initial experience.

Authors:  Anna S Nagle; John E Speich; Stefan G De Wachter; Peter P Ghamarian; David M Le; Andrew F Colhoun; Paul H Ratz; Robert W Barbee; Adam P Klausner
Journal:  Neurourol Urodyn       Date:  2016-09-21       Impact factor: 2.696

10.  Reliability testing of urodynamics, pressure flow studies and cough leak point pressure in women with urodynamic stress incontinence with and without detrusor overactivity.

Authors:  Philip Rahmanou; Charlotte Chaliha; Elena Kulinskaya; Vik Khullar
Journal:  Int Urogynecol J Pelvic Floor Dysfunct       Date:  2008-02-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.