Derek Sheen1, Hiren Kolli1, Anna S Nagle2, Zachary Cullingsworth2, Naomi N Vinod1, Hameeda A Naimi1, Stefan G De Wachter3,4, Suzanne E Mazzeo5, Lynn Stothers6, John E Speich2, Adam P Klausner1. 1. Department of Surgery/Division of Urology, Virginia Commonwealth University School of Medicine, Richmond, Virginia. 2. Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University College of Engineering, Richmond, Virginia. 3. Department of Urology, University Hospital Antwerpen, Edegem, Belgium. 4. Department of Urology, University of Antwerpen, Wilrijk, Belgium. 5. Department of Psychology, Virginia Commonwealth University, College of Humanities and Sciences, Richmond, Virginia. 6. Department of Urologic Sciences, University of British Columbia, Vancouver, British Columbia, Canada.
Abstract
OBJECTIVES: A non-invasive protocol was previously developed using three-dimensional ultrasound and a sensation meter to characterize real-time bladder sensation. This study the protocol by measuring the effects of fill rateand ultrasound probe pressure during oral hydration. METHODS: Healthy volunteers with no urinary symptoms (based on International Consultation on Incontinence Questionnaire on Overactive Bladder surveys) were recruited into an oral hydration study. Throughout two complete fill-void cycles, participants drank 2 L Gatorade G2 (The Gatorade Company, Inc., Chicago, Illinois) and used a touch-screen sensation meter to record real-time bladder sensation (0%-100%). The study was repeated three times, once per week (Visits A, B, and C). In Visits A and B, ultrasound was used to measure bladder volume every 5 minutes. Ultrasound was not used in Visit C except at 100% capacity. Volume data from Visit B were used to estimate volumes throughout the fills in Visit C. Sensation-capacity curves were generated for each fill for comparative analysis. RESULTS: Ten participants completed three visits (60 total fills). Increased fill rate led to decreased sensation throughout filling, andultrasound probe pressure led to increased sensation. Participants reported higher sensation at low volumes during Fill 1 of Visit A before training with the sensation meter. Sensation curves with intermittent ultrasound showed repeatability for Fill 2 in Visits A and B. Fill rate and ultrasound probe pressure affect real-time bladder sensation during oral hydration. CONCLUSIONS: This study demonstrated repeatability of real-time bladder sensation during a two-fill oral hydration protocol with ultrasound.
OBJECTIVES: A non-invasive protocol was previously developed using three-dimensional ultrasound and a sensation meter to characterize real-time bladder sensation. This study the protocol by measuring the effects of fill rateand ultrasound probe pressure during oral hydration. METHODS: Healthy volunteers with no urinary symptoms (based on International Consultation on Incontinence Questionnaire on Overactive Bladder surveys) were recruited into an oral hydration study. Throughout two complete fill-void cycles, participants drank 2 L Gatorade G2 (The Gatorade Company, Inc., Chicago, Illinois) and used a touch-screen sensation meter to record real-time bladder sensation (0%-100%). The study was repeated three times, once per week (Visits A, B, and C). In Visits A and B, ultrasound was used to measure bladder volume every 5 minutes. Ultrasound was not used in Visit C except at 100% capacity. Volume data from Visit B were used to estimate volumes throughout the fills in Visit C. Sensation-capacity curves were generated for each fill for comparative analysis. RESULTS: Ten participants completed three visits (60 total fills). Increased fill rate led to decreased sensation throughout filling, andultrasound probe pressure led to increased sensation. Participants reported higher sensation at low volumes during Fill 1 of Visit A before training with the sensation meter. Sensation curves with intermittent ultrasound showed repeatability for Fill 2 in Visits A and B. Fill rate and ultrasound probe pressure affect real-time bladder sensation during oral hydration. CONCLUSIONS: This study demonstrated repeatability of real-time bladder sensation during a two-fill oral hydration protocol with ultrasound.
Authors: Firdaweke G Habteyes; S Omid Komari; Anna S Nagle; Adam P Klausner; Rebecca L Heise; Paul H Ratz; John E Speich Journal: J Mech Behav Biomed Mater Date: 2017-02-20
Authors: Stefan G G De Wachter; Rhea Heeringa; Gommert A Van Koeveringe; Bjorn Winkens; Philip E V Van Kerrebroeck; James I Gillespie Journal: Neurourol Urodyn Date: 2013-06-21 Impact factor: 2.696
Authors: Stephanie Glass Clark; Anna S Nagle; Rachel Bernardo; Naomi Vinod; Laura Carucci; Ashley Carroll; John Speich; Adam P Klausner Journal: Female Pelvic Med Reconstr Surg Date: 2020-10 Impact factor: 2.091
Authors: Hiren Kolli; Anna S Nagle; Derek Sheen; Hameeda A Naimi; Naomi N Vinod; Zachary E Cullingsworth; Rui Li; Adam P Klausner; John E Speich Journal: Am J Clin Exp Urol Date: 2022-02-15
Authors: Rui Li; Anna S Nagle; Kaitlyn M Maddra; Naomi Vinod; Suzanne A Prince; Sarah I Tensen; Devina Thapa; Blessan Sebastian; Dhruv Sethi; Abraham Alattar; Laura R Carucci; Adam P Klausner; John E Speich Journal: Am J Clin Exp Urol Date: 2021-10-15
Authors: Blessan Sebastian; Natalie R Swavely; Dhruv Sethi; Anna S Nagle; Devina Thapa; Naomi N Vinod; Zachary E Cullingsworth; Andrea K Balthazar; Adam P Klausner; John E Speich Journal: Arch Nephrol Urol Stud Date: 2021-11-26