Literature DB >> 1522088

A quantitative evaluation of periprosthetic bone-remodeling after cementless total hip arthroplasty.

C A Engh1, T F McGovern, J D Bobyn, W H Harris.   

Abstract

Dual-energy x-ray absorptiometry analysis was used to determine the periprosthetic bone-mineral content of ten femora that had been obtained at the autopsies of five elderly patients who had had an AML (anatomic medullary locking) prosthesis in situ for seventeen to eighty-four months. Clinical radiographs showed resorptive remodeling changes characteristic of femora containing this implant. Before the absorptiometry was performed, an identical prosthesis had been inserted into the contralateral, normal femur of each cadaver. The mean difference in the periprosthetic bone-mineral content between the remodeled femora and the femora in which the prosthesis had been implanted post mortem ranged from 7 to 52 per cent, with the bone-mineral content always less in the remodeled femora. The greatest mean decrease in bone-mineral content (45 per cent) occurred adjacent to the proximal one-third of the remodeled femora. The percentage decrease in periprosthetic bone-mineral content in the remodeled femora had an inverse linear relationship with the corresponding bone-mineral content of the contralateral control femora. Preoperative analysis of bone density may therefore be useful for prediction of the extent of resorptive bone-remodeling after total hip replacement.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1522088

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  39 in total

1.  Bilayered calcium phosphate coating to promote osseointegration of a femoral stem prosthesis.

Authors:  E Goyenvalle; N J M Guyen; E Aguado; N Passuti; G Daculsi
Journal:  J Mater Sci Mater Med       Date:  2003-03       Impact factor: 3.896

2.  Early aseptic loosening of cemented total hip arthroplasty: the influence of non-steroidal anti-inflammatory drugs and smoking.

Authors:  M H A Malik; J Gray; P R Kay
Journal:  Int Orthop       Date:  2004-03-27       Impact factor: 3.075

3.  Effects of heat treatment of wood on hydroxylapatite type mineral precipitation and biomechanical properties in vitro.

Authors:  J Rekola; L V J Lassila; J Hirvonen; M Lahdenperä; R Grenman; A J Aho; P K Vallittu
Journal:  J Mater Sci Mater Med       Date:  2010-05-13       Impact factor: 3.896

4.  Excellent results with cementless total hip arthroplasty and alumina-on-alumina pairing: minimum ten-year follow-up.

Authors:  Alexander M Kress; Rainer Schmidt; Ulrich Holzwarth; Raimund Forst; Lutz A Mueller
Journal:  Int Orthop       Date:  2010-11-16       Impact factor: 3.075

5.  [Periprosthetic bone loss after total hip endoprosthesis. Dependence on the type of prosthesis and preoperative bone configuration].

Authors:  A Roth; G Richartz; K Sander; A Sachse; R Fuhrmann; A Wagner; R-A Venbrocks
Journal:  Orthopade       Date:  2005-04       Impact factor: 1.087

6.  Preoperative bone quality as a factor in dual-energy X-ray absorptiometry analysis comparing bone remodelling between two implant types.

Authors:  Bart Cornelis Hendrikus van der Wal; Ali Rahmy; Bernd Grimm; Ide Heyligers; Alphons Tonino
Journal:  Int Orthop       Date:  2006-11-04       Impact factor: 3.075

7.  Long-term periprosthetic remodeling in THA shows structural preservation.

Authors:  James B Stiehl
Journal:  Clin Orthop Relat Res       Date:  2009-02-14       Impact factor: 4.176

8.  Cementless total hip arthroplasty in patients with rheumatoid arthritis using a tapered designed titanium hip stem minimum: 10-year results.

Authors:  Hans D Carl; Jan Ploetzner; Bernd Swoboda; Gerd Weseloh; Lutz Arne Mueller
Journal:  Rheumatol Int       Date:  2009-12-18       Impact factor: 2.631

9.  Late remodeling around a proximally HA-coated tapered titanium femoral component.

Authors:  William N Capello; James A D'Antonio; Rudolph G Geesink; Judy R Feinberg; Marybeth Naughton
Journal:  Clin Orthop Relat Res       Date:  2008-10-11       Impact factor: 4.176

10.  Minimal stress shielding with a Mallory-Head titanium femoral stem with proximal porous coating in total hip arthroplasty.

Authors:  Brad Ellison; Nicholas A Cheney; Keith R Berend; Adolph V Lombardi; Thomas H Mallory
Journal:  J Orthop Surg Res       Date:  2009-12-09       Impact factor: 2.359

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.